Trane SWT02124 OEM 180°F Manual Reset Flame Rollout Switch

  • Genuine Trane / American Standard OEM furnace safety replacement

  • Fixed 180°F (82°C) flame rollout temperature rating

  • Factory replacement part number SWT02124

  • Rated 5.8 FLA and 34.8 LRA at 120 VAC

  • Manual-reset, non-trip-free operating design

Please visit our store for pick up.

Quantity

safe & secure Checkout

Fast & Tracked Delivery
30 Day money back guarantee

Specifications

Product Details & Specifications

Specification

Details

Manufacturer

Trane

Brand

Trane / American Standard

Manufacturer Part Number

SWT02124

OEM Description

Switch – Flame Rollout

Product Type

Flame Rollout Safety Switch

Component Category

Furnace Temperature & Safety Controls

Operating Temperature

180°F (82°C)

Reset Type

Manual Reset

Trip Mechanism

Non-Trip Free

Temperature Control

Fixed Temperature

Adjustability

Non-Adjustable

Full Load Amperage (FLA)

5.8 A at 120 VAC

Locked Rotor Amperage (LRA)

34.8 A at 120 VAC

Additional Voltage Rating

24 VAC, as listed

Contact Configuration

Verify manufacturer specifications

Normal Contact State

Verify manufacturer specifications

Terminal Configuration

Verify original component

Mounting Configuration

Equipment-specific

Primary Function

Flame Rollout / Overtemperature Safety Protection

Equipment Application

Compatible Trane / American Standard Gas Heating Equipment

Replacement Type

OEM Factory Replacement

Installation

Qualified HVAC Technician Required

Specification Note: The temperature, manual-reset design, non-trip-free designation, and electrical ratings are based on the supplied OEM description. The specific electrical rating applicable at 24 VAC, contact arrangement, and mounting dimensions require manufacturer verification.

description

The Trane American Standard SWT02124 Flame Rollout Switch is an OEM temperature-actuated safety control designed for compatible Trane and American Standard gas heating equipment.

Featuring a fixed operating temperature of 180°F (82°C), this flame rollout switch is designed to respond to excessive heat in the furnace's designated safety monitoring area. When abnormal temperatures reach the switch's specified threshold, the control activates to interrupt the applicable furnace safety circuit.

The SWT02124 features a manual-reset, non-trip-free design, requiring proper inspection and reset procedures following activation. Its fixed-temperature, non-adjustable construction helps maintain the manufacturer's intended temperature safety protection.

The supplied electrical specifications include 5.8 FLA and 34.8 LRA at 120 VAC, along with a listed 24 VAC rating. These ratings should be matched to the original component and the manufacturer's equipment requirements.

Designed for equipment-specific replacement, the Trane SWT02124 is intended for professional furnace service, maintenance, and repair.

Key Features & Function

  • Brand: Trane / American Standard
  • Manufacturer Part Number: SWT02124
  • OEM Description: Flame Rollout Switch
  • Genuine OEM replacement furnace safety component
  • Temperature Rating: 180°F (82°C)
  • Reset Type: Manual Reset
  • Trip Mechanism: Non-Trip Free
  • Temperature Setting: Fixed, Non-Adjustable
  • Full Load Rating: 5.8 FLA at 120 VAC
  • Locked Rotor Rating: 34.8 LRA at 120 VAC
  • Additional Listed Voltage: 24 VAC
  • Temperature-actuated electrical switching
  • Supports furnace flame rollout and overtemperature protection
  • Designed for compatible Trane and American Standard heating equipment
  • Equipment-specific electrical and mounting configuration

Product Details & Specifications

Specification

Details

Manufacturer

Trane

Brand

Trane / American Standard

Manufacturer Part Number

SWT02124

OEM Description

Switch – Flame Rollout

Product Type

Flame Rollout Safety Switch

Component Category

Furnace Temperature & Safety Controls

Operating Temperature

180°F (82°C)

Reset Type

Manual Reset

Trip Mechanism

Non-Trip Free

Temperature Control

Fixed Temperature

Adjustability

Non-Adjustable

Full Load Amperage (FLA)

5.8 A at 120 VAC

Locked Rotor Amperage (LRA)

34.8 A at 120 VAC

Additional Voltage Rating

24 VAC, as listed

Contact Configuration

Verify manufacturer specifications

Normal Contact State

Verify manufacturer specifications

Terminal Configuration

Verify original component

Mounting Configuration

Equipment-specific

Primary Function

Flame Rollout / Overtemperature Safety Protection

Equipment Application

Compatible Trane / American Standard Gas Heating Equipment

Replacement Type

OEM Factory Replacement

Installation

Qualified HVAC Technician Required

Specification Note: The temperature, manual-reset design, non-trip-free designation, and electrical ratings are based on the supplied OEM description. The specific electrical rating applicable at 24 VAC, contact arrangement, and mounting dimensions require manufacturer verification.

HVAC Depot Pro Tip

A flame rollout switch that trips is an important warning that the furnace may be experiencing a dangerous combustion or venting condition.

Before replacing or resetting the Trane SWT02124, a qualified HVAC technician should identify the cause of the excessive temperature.

Recommended diagnostic checks:

  1. Confirm the complete furnace model and serial number.
  2. Verify the original rollout switch part number is SWT02124.
  3. Inspect the burner compartment for evidence of excessive heat.
  4. Check the venting system for blockages or restrictions.
  5. Inspect the heat exchanger for damage or deterioration.
  6. Verify inducer motor and combustion airflow operation.
  7. Check burner ignition and flame characteristics.
  8. Inspect electrical terminals and wiring for heat damage.
  9. Verify the replacement has the correct 180°F temperature rating.
  10. Confirm the correct manual-reset and mounting configuration.

HVAC Depot Pro Tip: The SWT02124 uses a non-trip-free manual-reset mechanism. This design characteristic must match the manufacturer-approved replacement requirements. Do not substitute a trip-free or automatic-reset switch without explicit manufacturer authorization.

Important Safety Warning: Never bypass or jumper a flame rollout switch. If the switch has activated, discontinue furnace operation until a qualified technician has diagnosed and corrected the underlying condition.

Do not repeatedly reset a tripped flame rollout switch to restore heating operation.

Equipment / Model Compatibility

The Trane SWT02124 is intended for select Trane and American Standard gas heating equipment requiring this specific OEM flame rollout switch.

Exact compatible furnace models have not been independently verified.

Before ordering, confirm:

  • Complete equipment model number
  • Furnace serial number
  • Original flame rollout switch part number
  • Required 180°F operating temperature
  • Manual-reset configuration
  • Non-trip-free design requirement
  • Electrical contact and voltage ratings
  • Terminal configuration
  • Mounting dimensions and installation location

Compatibility Notice: SWT02124 is not a universal flame rollout switch. Matching the temperature rating alone does not guarantee compatibility.

 

Specification

Refund policy

Refund & Return Policy

Last Updated: June 2026

At HVAC Parts & Equipment Depot, customer satisfaction is important to us. This Refund & Return Policy explains how returns, exchanges, and refunds are handled for purchases made through TopHVACParts.com.

Return Eligibility

We accept returns within 30 days of delivery.

To qualify for a return:

  • The item must be unused, uninstalled, and in its original condition.
  • The item must be returned in its original packaging.
  • Model numbers and serial numbers must match the original purchase records.
  • Proof of purchase or order confirmation is required.

Non-Returnable Items

The following items are not eligible for return or refund:

  • Installed or used parts.
  • Products showing signs of installation, modification, or damage caused after delivery.
  • Items missing original packaging.
  • Sale or clearance items.
  • Special-order or custom-order products.
  • Returns requested more than 30 days after delivery.

Restocking Fee

Approved returns may be subject to a 20% restocking fee.

The restocking fee will be deducted from the refund amount after the returned item has been inspected and approved.

Damaged, Defective, or Incorrect Items

If you receive a damaged, defective, or incorrect item, please contact us within 7 days of delivery.

Email: support@tophvacparts.com
Phone: (214) 734-5222

We may request photographs and additional information to help process your claim.

If the claim is approved, we will provide a replacement, exchange, or refund at no additional cost to you.

Exchanges

We replace items only if they are defective, damaged upon arrival, or incorrectly shipped.

To request an exchange, contact us at:

support@tophvacparts.com

Refund Process

Once your return is received and inspected, we will notify you by email regarding approval or rejection of your refund request.

If approved:

  • Refunds will be issued to the original payment method.
  • Processing typically takes 7–14 business days after approval.
  • Your financial institution may require additional time before the refund appears in your account.

Return Shipping

Customers are responsible for return shipping costs unless the return is the result of:

  • Our shipping error,
  • A defective product,
  • A damaged product received upon delivery.

Original shipping charges are non-refundable.

We recommend using a trackable shipping service and purchasing shipping insurance for higher-value items.

Return Address

HVAC Parts & Equipment Depot
1135 E Plano Parkway, Suite 8
Plano, TX 75074
United States

Professional Installation Notice

Many HVAC products require installation by a licensed HVAC professional.

HVAC Parts & Equipment Depot is not responsible for damages resulting from improper installation, misuse, unauthorized modifications, or failure to follow manufacturer instructions.

Special Orders

Special-order products must be picked up within 30 days of purchase unless other arrangements have been approved.

Unclaimed special-order products may be returned to the manufacturer and may be subject to applicable restocking fees.

Contact Us

If you have questions regarding returns, refunds, or exchanges, please contact us:

HVAC Parts & Equipment Depot

Phone: (214) 734-5222
Email: support@tophvacparts.com

Michel & Siso are very knowledgeable and explain everything to where I could understand! Amazing experience! Thank you will always come here for any AC needs. Trustworthy and excellent customer service.

Celest G.
Verified Customer
View full details

Happy Shouts From Our Thrilled Customers

YOU MAY ALSO LIKE

Explore More Products

HVAC Parts and Equipment Depot

Frequently Asked Questions

Questions? We’ve got you covered

We are open to the public! Homeowners, landlords, and DIYers are all welcome—no license required.

We carry blower motors, fan motors, capacitors, control boards, contactors, thermostats, filters, copper lines, refrigerants, and more.

Yes, we stock OEM and compatible replacement parts for major brands including Trane, Goodman, Lennox, Carrier, Rheem, and others.

Absolutely! Bring in the part, model number, or a picture, and our team will help match you with the correct replacement.

Yes, we accept returns or exchanges within a set time period—just make sure the item is unused and in original packaging. Ask for specific terms at the counter.

While we don't install, we can answer basic questions and refer you to trusted local HVAC technicians if needed.

We sell certain refrigerants, but EPA regulations require certification for purchase of products like R-410A or R-22.

We offer both! You can shop in person or call to arrange shipping if you're out of town.