ICM2813 Furnace Control Board | Lennox SureLight Replacement | Replaces 10M9301 & 50A65-120

ICM2813 Furnace Control Board | Lennox SureLight Replacement | Replaces 10M9301 & 50A65-120

Out of stock

Regular price $0.00 USD
Regular price Sale price $0.00 USD
Sale Sold out
Shipping calculated at checkout.

Lennox SureLight Replacement Specs

  • Direct Lennox SureLight® Replacement. Specifically engineered to replace Lennox 10M9301 and the White-Rodgers 50A65 series. Ideal for restoring Hot Surface Ignition (HSI) systems.

  • Onboard Diagnostic LEDs. Simplifies troubleshooting by providing flash codes for system faults, safety switch trips, and ignition failures.

  • Full Safety Circuit Oversight. Continuously monitors high limit, rollout, and auxiliary limit switches to ensure 100% safe furnace operation.

  • Heavy-Duty Relays. Supports 2-speed circulating blowers (9.5 FLA) and inducer draft motors (2.2 FLA) with precision microprocessor timing.

  • Wide Temperature Tolerance. Built to operate in extreme environments ranging from -40°F to 176°F with a 5% to 95% non-condensing humidity range.

Please visit our store for pick up.

Quantity

safe & secure Checkout

Fast & Tracked Delivery
30 Day money back guarantee

Specifications

Technical Specifications:

  • Input Voltage: 18-30 VAC, 60 Hz
  • Ignitor Current: 2.0 Amp @ 80 VAC, 60 Hz
  • Inducer Relay: 2.2 FLA / 3.5 LRA @ 120 VAC
  • Blower Relay: 9.5 FLA / 25.0 LRA @ 120 VAC (2-Speed)
  • Gas Valve Relay: 1.5 Amp @ 25 VAC
  • Operating Temp: -40°F to 176°F (-40°C to 80°C)
  • Electrical rating: @ 77°F (25°C)
  • Gas valve relay: 1.5 amp @ 25 VAC, 60 Hz 0.6 pf

description

Restore Your Lennox Furnace Performance!

The ICM2813 is a high-precision, microprocessor-based furnace control board designed as a form, fit, and functional replacement for the Lennox SureLight® Series and popular White-Rodgers equivalents. This American-made board manages every critical stage of your furnace's operation—from the inducer and pressure switches to the hot surface ignitor and blower motor—ensuring your home stays warm and safe all winter long.


Why the ICM2813 is the Professional’s Choice:

  • Total System Monitoring: Actively manages the ignition sequence while maintaining 100% safety circuit monitoring, including high limit, rollout, and auxiliary limit switches.
  • Diagnostic Precision: Features built-in diagnostic LEDs that flash specific fault codes, allowing you to quickly identify if the issue is a pressure switch, flame sense, or ignition failure.
  • Durable in Extreme Conditions: Rated for an operating temperature range of -40°F to 176°F, ensuring reliability in the coldest attics or hottest utility closets.
  • Dual-Speed Blower Support: Integrated relays for 2-speed (Heat/Cool) blower motors and inducer draft motors.


Comprehensive Cross-Reference Guide

The ICM2813 is a direct replacement for the following Lennox and White-Rodgers part numbers:

Lennox SureLight Series:

  • 10M9301, 12L6901, 32M8801, 56L8401, 24L8501, 63K8901, 97L4801, 100925-01, 100925-03, 17W9201, 23W5101, 30W2501, 69M0801, 69M1501, 83M00.

White-Rodgers:

  • 50A65-120, 50A65-121, 50A62-120, 50A62-121, 50A62-820, 21D83M-843, 50A66-122, 50A66-123.


Technical Specifications:

  • Input Voltage: 18-30 VAC, 60 Hz
  • Ignitor Current: 2.0 Amp @ 80 VAC, 60 Hz
  • Inducer Relay: 2.2 FLA / 3.5 LRA @ 120 VAC
  • Blower Relay: 9.5 FLA / 25.0 LRA @ 120 VAC (2-Speed)
  • Gas Valve Relay: 1.5 Amp @ 25 VAC
  • Operating Temp: -40°F to 176°F (-40°C to 80°C)
  • Electrical rating: @ 77°F (25°C)
  • Gas valve relay: 1.5 amp @ 25 VAC, 60 Hz 0.6 pf

Specification

Refund policy

Refund & Return Policy

Last Updated: June 2026

At HVAC Parts & Equipment Depot, customer satisfaction is important to us. This Refund & Return Policy explains how returns, exchanges, and refunds are handled for purchases made through TopHVACParts.com.

Return Eligibility

We accept returns within 30 days of delivery.

To qualify for a return:

  • The item must be unused, uninstalled, and in its original condition.
  • The item must be returned in its original packaging.
  • Model numbers and serial numbers must match the original purchase records.
  • Proof of purchase or order confirmation is required.

Non-Returnable Items

The following items are not eligible for return or refund:

  • Installed or used parts.
  • Products showing signs of installation, modification, or damage caused after delivery.
  • Items missing original packaging.
  • Sale or clearance items.
  • Special-order or custom-order products.
  • Returns requested more than 30 days after delivery.

Restocking Fee

Approved returns may be subject to a 20% restocking fee.

The restocking fee will be deducted from the refund amount after the returned item has been inspected and approved.

Damaged, Defective, or Incorrect Items

If you receive a damaged, defective, or incorrect item, please contact us within 7 days of delivery.

Email: support@tophvacparts.com
Phone: (214) 734-5222

We may request photographs and additional information to help process your claim.

If the claim is approved, we will provide a replacement, exchange, or refund at no additional cost to you.

Exchanges

We replace items only if they are defective, damaged upon arrival, or incorrectly shipped.

To request an exchange, contact us at:

support@tophvacparts.com

Refund Process

Once your return is received and inspected, we will notify you by email regarding approval or rejection of your refund request.

If approved:

  • Refunds will be issued to the original payment method.
  • Processing typically takes 7–14 business days after approval.
  • Your financial institution may require additional time before the refund appears in your account.

Return Shipping

Customers are responsible for return shipping costs unless the return is the result of:

  • Our shipping error,
  • A defective product,
  • A damaged product received upon delivery.

Original shipping charges are non-refundable.

We recommend using a trackable shipping service and purchasing shipping insurance for higher-value items.

Return Address

HVAC Parts & Equipment Depot
1135 E Plano Parkway, Suite 8
Plano, TX 75074
United States

Professional Installation Notice

Many HVAC products require installation by a licensed HVAC professional.

HVAC Parts & Equipment Depot is not responsible for damages resulting from improper installation, misuse, unauthorized modifications, or failure to follow manufacturer instructions.

Special Orders

Special-order products must be picked up within 30 days of purchase unless other arrangements have been approved.

Unclaimed special-order products may be returned to the manufacturer and may be subject to applicable restocking fees.

Contact Us

If you have questions regarding returns, refunds, or exchanges, please contact us:

HVAC Parts & Equipment Depot

Phone: (214) 734-5222
Email: support@tophvacparts.com

Michel & Siso are very knowledgeable and explain everything to where I could understand! Amazing experience! Thank you will always come here for any AC needs. Trustworthy and excellent customer service.

Celest G.
Verified Customer
View full details

Happy Shouts From Our Thrilled Customers

YOU MAY ALSO LIKE

Explore More Products

HVAC Parts and Equipment Depot

Frequently Asked Questions

Questions? We’ve got you covered

We are open to the public! Homeowners, landlords, and DIYers are all welcome—no license required.

We carry blower motors, fan motors, capacitors, control boards, contactors, thermostats, filters, copper lines, refrigerants, and more.

Yes, we stock OEM and compatible replacement parts for major brands including Trane, Goodman, Lennox, Carrier, Rheem, and others.

Absolutely! Bring in the part, model number, or a picture, and our team will help match you with the correct replacement.

Yes, we accept returns or exchanges within a set time period—just make sure the item is unused and in original packaging. Ask for specific terms at the counter.

While we don't install, we can answer basic questions and refer you to trusted local HVAC technicians if needed.

We sell certain refrigerants, but EPA regulations require certification for purchase of products like R-410A or R-22.

We offer both! You can shop in person or call to arrange shipping if you're out of town.