ICM2811 Furnace Control Board | Goodman & Amana PCBBF112 Replacement | Replaces 0130F00005

ICM2811 Furnace Control Board | Goodman & Amana PCBBF112 Replacement | Replaces 0130F00005

Out of stock

Regular price $0.00 USD
Regular price Sale price $0.00 USD
Sale Sold out
Shipping calculated at checkout.

Goodman & Amana Technical Highlights

  • Direct Goodman PCBBF Replacement. Engineered to replace Goodman PCBBF112, PCBBF123, and White-Rodgers 50A55-743 controls.

  • Onboard Fault Code LEDs. Includes a diagnostic LED that provides clear flash codes for fast troubleshooting of system and safety switches.

  • Built-in Circuit Protection. Features reverse polarity protection and 100% gas shutoff safety for maximum system security.

  • Twinning Compatible. Capable of working in tandem with another ICM2811 board for synchronized operation in twinned furnace systems.

  • Heavy-Duty Output. Rated to handle up to 6.0A for ignitors and 14.5A for two-speed circulating blower motors.

Please visit our store for pick up.

Quantity

safe & secure Checkout

Fast & Tracked Delivery
30 Day money back guarantee

Specifications

Technical Specifications:

  • Control Voltage: 18-30 VAC, 60 Hz
  • Ignitor Current: 6.0 Amp @ 120 VAC
  • Inducer Relay: 2.2 FLA / 3.5 LRA @ 120 VAC
  • Blower Relay: 14.5 FLA / 25.0 LRA @ 120 VAC (2-Speed)
  • Gas Valve Relay: 1.5 Amp @ 25 VAC
  • Operating Temp: -40°F to 176°F
  • Input Voltage: 120 VAC
  • Humidity Range: 5 to 95% relative humidity (non-condensing)
  • Electrical Ratings were made at 77°F (25°C)

description

Reliable Control for Your Goodman or Amana Furnace

Stop your furnace from blowing cold air or failing to ignite with the ICM2811. This American-made, microprocessor-based control board is a direct form, fit, and functional replacement for Goodman, Amana, and Janitrol OEM parts. Specifically designed for Hot Surface Ignition (HSI) systems, it manages the gas valve, inducer draft motor, and circulating blower with precision. 


Why the ICM2811 is the Smart Choice for Repairs: 

  • Direct OEM Replacement: Seamlessly replaces common Goodman part numbers like PCBBF112, PCBBF123, and 0130F00005.
  • Advanced Diagnostics: Features a built-in diagnostic LED that illuminates specific flash codes, allowing you or a technician to troubleshoot pressure switches, limit switches, or flame sense issues in seconds.
  • Safety & Reliability: Includes a 100% gas shutoff feature in case of ignition failure and integrated reverse polarity protection to safeguard your system's electronics.
  • Twinning Compatible: Ready for dual-furnace setups, this board can be twinned with another ICM2811 to synchronize blower operation across two units.

 

Goodman & White-Rodgers Cross-Reference:

This board is a wire-for-wire replacement for the following part numbers:

Goodman / Amana / Janitrol:

  • PCBBF110
  • PCBBF110S
  • PCBBF112
  • PCBBF112S
  • PCBBF123
  • PCBBF123S
  • 0130F00005
  • 0130F00005S
  • B18099-26
  • B18099-26S

White-Rodgers:

  • 50A55-743
  • 50A55-289
  • 50T55-289


Technical Specifications:

  • Control Voltage: 18-30 VAC, 60 Hz
  • Ignitor Current: 6.0 Amp @ 120 VAC
  • Inducer Relay: 2.2 FLA / 3.5 LRA @ 120 VAC
  • Blower Relay: 14.5 FLA / 25.0 LRA @ 120 VAC (2-Speed)
  • Gas Valve Relay: 1.5 Amp @ 25 VAC
  • Operating Temp: -40°F to 176°F
  • Input Voltage: 120 VAC
  • Humidity Range: 5 to 95% relative humidity (non-condensing)
  • Electrical Ratings were made at 77°F (25°C)


Pro-Tip: Solve the "No Ignition" Mystery

When installing the ICM2811, ensure your furnace has a solid, clean ground connection. Because this board uses a microprocessor for "Flame Sensing," a weak ground is the #1 reason for a "No Flame Detected" fault code—even if your ignitor is glowing. Before finalizing your install, take a piece of steel wool or sandpaper to the ground screw area to ensure metal-to-metal contact. This small step often solves intermittent ignition failures that look like a "bad board" but are actually just a ground loop issue!

Specification

Refund policy

Refund & Return Policy

Last Updated: June 2026

At HVAC Parts & Equipment Depot, customer satisfaction is important to us. This Refund & Return Policy explains how returns, exchanges, and refunds are handled for purchases made through TopHVACParts.com.

Return Eligibility

We accept returns within 30 days of delivery.

To qualify for a return:

  • The item must be unused, uninstalled, and in its original condition.
  • The item must be returned in its original packaging.
  • Model numbers and serial numbers must match the original purchase records.
  • Proof of purchase or order confirmation is required.

Non-Returnable Items

The following items are not eligible for return or refund:

  • Installed or used parts.
  • Products showing signs of installation, modification, or damage caused after delivery.
  • Items missing original packaging.
  • Sale or clearance items.
  • Special-order or custom-order products.
  • Returns requested more than 30 days after delivery.

Restocking Fee

Approved returns may be subject to a 20% restocking fee.

The restocking fee will be deducted from the refund amount after the returned item has been inspected and approved.

Damaged, Defective, or Incorrect Items

If you receive a damaged, defective, or incorrect item, please contact us within 7 days of delivery.

Email: support@tophvacparts.com
Phone: (214) 734-5222

We may request photographs and additional information to help process your claim.

If the claim is approved, we will provide a replacement, exchange, or refund at no additional cost to you.

Exchanges

We replace items only if they are defective, damaged upon arrival, or incorrectly shipped.

To request an exchange, contact us at:

support@tophvacparts.com

Refund Process

Once your return is received and inspected, we will notify you by email regarding approval or rejection of your refund request.

If approved:

  • Refunds will be issued to the original payment method.
  • Processing typically takes 7–14 business days after approval.
  • Your financial institution may require additional time before the refund appears in your account.

Return Shipping

Customers are responsible for return shipping costs unless the return is the result of:

  • Our shipping error,
  • A defective product,
  • A damaged product received upon delivery.

Original shipping charges are non-refundable.

We recommend using a trackable shipping service and purchasing shipping insurance for higher-value items.

Return Address

HVAC Parts & Equipment Depot
1135 E Plano Parkway, Suite 8
Plano, TX 75074
United States

Professional Installation Notice

Many HVAC products require installation by a licensed HVAC professional.

HVAC Parts & Equipment Depot is not responsible for damages resulting from improper installation, misuse, unauthorized modifications, or failure to follow manufacturer instructions.

Special Orders

Special-order products must be picked up within 30 days of purchase unless other arrangements have been approved.

Unclaimed special-order products may be returned to the manufacturer and may be subject to applicable restocking fees.

Contact Us

If you have questions regarding returns, refunds, or exchanges, please contact us:

HVAC Parts & Equipment Depot

Phone: (214) 734-5222
Email: support@tophvacparts.com

Michel & Siso are very knowledgeable and explain everything to where I could understand! Amazing experience! Thank you will always come here for any AC needs. Trustworthy and excellent customer service.

Celest G.
Verified Customer
View full details

Happy Shouts From Our Thrilled Customers

YOU MAY ALSO LIKE

Explore More Products

HVAC Parts and Equipment Depot

Frequently Asked Questions

Questions? We’ve got you covered

We are open to the public! Homeowners, landlords, and DIYers are all welcome—no license required.

We carry blower motors, fan motors, capacitors, control boards, contactors, thermostats, filters, copper lines, refrigerants, and more.

Yes, we stock OEM and compatible replacement parts for major brands including Trane, Goodman, Lennox, Carrier, Rheem, and others.

Absolutely! Bring in the part, model number, or a picture, and our team will help match you with the correct replacement.

Yes, we accept returns or exchanges within a set time period—just make sure the item is unused and in original packaging. Ask for specific terms at the counter.

While we don't install, we can answer basic questions and refer you to trusted local HVAC technicians if needed.

We sell certain refrigerants, but EPA regulations require certification for purchase of products like R-410A or R-22.

We offer both! You can shop in person or call to arrange shipping if you're out of town.