Michel & Siso are very knowledgeable and explain everything to where I could understand! Amazing experience! Thank you will always come here for any AC needs. Trustworthy and excellent customer service.

Celest G.
Verified Customer

4.9/5 based on 4750 reviews

ICM2810 Furnace Control Board | Goodman & Amana B1809926 Replacement | Replaces PCBBF101S

ICM2810 Furnace Control Board | Goodman & Amana B1809926 Replacement | Replaces PCBBF101S

Out of stock

Regular price $0.00 USD
Regular price Sale price $0.00 USD
Sale Sold out
Shipping calculated at checkout.

Goodman/Janitrol Board Specifications

  • Direct Goodman PCBBF101 Replacement. Engineered as a wire-for-wire replacement for Goodman B1809926 and PCBBF101S series control boards.

  • Onboard LED Troubleshooting. Built-in diagnostic LED provides flash codes for instant identification of furnace and safety circuit faults.

  • 100% Lockout Safety. Features microprocessor-controlled safety circuits with 100% gas shutoff upon ignition failure and reverse polarity protection.

  • Standard 9-Pin Connector. Uses the industry-standard 9-pin Molex connector for a fast, "plug-and-play" installation process.

  • USA-Designed & UL Recognized. Built with microprocessor precision to ensure accurate timing and 100% gas shutoff safety.

Please visit our store for pick up.

Quantity

safe & secure Checkout

Fast & Tracked Delivery
30 Day money back guarantee

Specifications

Technical Specifications:

  • Control Voltage: 24 VAC (18-30 VAC), 60 Hz
  • Line Voltage: 115 VAC, 60 Hz
  • Ignition Type: Hot Surface Ignition (HSI)
  • Ignitor Current: 6.0 Amp @ 120 VAC
  • Blower Relay: 14.5 FLA / 25.0 LRA @ 120 VAC
  • Safety Features: 100% Gas Shutoff & Reverse Polarity Protection

description

ICM2810 Furnace Control Board | Goodman & Amana B1809926 Replacement | Replaces PCBBF101S

Goodman, Amana, and Janitrol furnaces that use a single-stage, Hot Surface Ignition (HSI) system. This board is a "gold standard" for DIY repairs because of its simple layout and direct 9-pin compatibility.


Restore Reliability to Your Goodman or Amana Heating System

Is your furnace failing to kick on, or is the blower motor acting inconsistently? The ICM2810 is a microprocessor-based furnace control board designed as a high-quality, low-cost replacement for Goodman, Amana, and Janitrol OEM controls. This American-made board manages the ignition sequence, gas valve, and blower functions with modernized precision, ensuring your furnace operates safely and efficiently.


Why the ICM2810 is the Best Choice for Your Repair:

  • Direct Wire-for-Wire Replacement: Specifically engineered to replace the Goodman B1809926 and PCBBF101 series, making installation straightforward for homeowners and technicians alike.
  • Precision Microprocessor Timing: Eliminates the "drift" found in older analog boards, providing accurate timing for the inducer, ignitor, and blower cycles.
  • Instant Diagnostics: Features an onboard diagnostic LED that flashes clear fault codes. No more guessing—quickly identify if the problem is a pressure switch, limit switch, or flame sensor issue.
  • Maximum Safety Protection: Built with a 100% gas shutoff safety feature and reverse polarity protection to safeguard your furnace's internal electronics from wiring errors.
  • Universal System Support: Works with all standard 24 VAC thermostats and supports both 80+ and 90+ AFUE gas furnace applications.


Comprehensive Cross-Reference Guide:

The ICM2810 is a direct functional replacement for the following part numbers:

  • Goodman / Amana / Janitrol:

    B1809926, B1809926S, PCBBF101, PCBBF101S, PCBBF103, PCBBF103S, 0130F00004, 0130F00004S.
  • White-Rodgers:

    50A55-250, 50A55-743.
  • UTEC:

    1012-933D.


Technical Specifications:

  • Control Voltage: 24 VAC (18-30 VAC), 60 Hz
  • Line Voltage: 115 VAC, 60 Hz
  • Ignition Type: Hot Surface Ignition (HSI)
  • Ignitor Current: 6.0 Amp @ 120 VAC
  • Blower Relay: 14.5 FLA / 25.0 LRA @ 120 VAC
  • Safety Features: 100% Gas Shutoff & Reverse Polarity Protection


Pro-Tip: The "Click" Test:

When you first power up your new ICM2810, listen for the distinct "click" of the relays. If the board receives power but you don't hear a click within 30 seconds of a heat call, check your Door Switch. A loose or bypassed furnace blower door can prevent the 120V line from reaching the board, making it look like a "dead board" when it’s actually a safety interlock issue.

Specification

Refund policy

Refund & Return Policy

Last Updated: June 2026

At HVAC Parts & Equipment Depot, customer satisfaction is important to us. This Refund & Return Policy explains how returns, exchanges, and refunds are handled for purchases made through TopHVACParts.com.

Return Eligibility

We accept returns within 30 days of delivery.

To qualify for a return:

  • The item must be unused, uninstalled, and in its original condition.
  • The item must be returned in its original packaging.
  • Model numbers and serial numbers must match the original purchase records.
  • Proof of purchase or order confirmation is required.

Non-Returnable Items

The following items are not eligible for return or refund:

  • Installed or used parts.
  • Products showing signs of installation, modification, or damage caused after delivery.
  • Items missing original packaging.
  • Sale or clearance items.
  • Special-order or custom-order products.
  • Returns requested more than 30 days after delivery.

Restocking Fee

Approved returns may be subject to a 20% restocking fee.

The restocking fee will be deducted from the refund amount after the returned item has been inspected and approved.

Damaged, Defective, or Incorrect Items

If you receive a damaged, defective, or incorrect item, please contact us within 7 days of delivery.

Email: support@tophvacparts.com
Phone: (214) 734-5222

We may request photographs and additional information to help process your claim.

If the claim is approved, we will provide a replacement, exchange, or refund at no additional cost to you.

Exchanges

We replace items only if they are defective, damaged upon arrival, or incorrectly shipped.

To request an exchange, contact us at:

support@tophvacparts.com

Refund Process

Once your return is received and inspected, we will notify you by email regarding approval or rejection of your refund request.

If approved:

  • Refunds will be issued to the original payment method.
  • Processing typically takes 7–14 business days after approval.
  • Your financial institution may require additional time before the refund appears in your account.

Return Shipping

Customers are responsible for return shipping costs unless the return is the result of:

  • Our shipping error,
  • A defective product,
  • A damaged product received upon delivery.

Original shipping charges are non-refundable.

We recommend using a trackable shipping service and purchasing shipping insurance for higher-value items.

Return Address

HVAC Parts & Equipment Depot
1135 E Plano Parkway, Suite 8
Plano, TX 75074
United States

Professional Installation Notice

Many HVAC products require installation by a licensed HVAC professional.

HVAC Parts & Equipment Depot is not responsible for damages resulting from improper installation, misuse, unauthorized modifications, or failure to follow manufacturer instructions.

Special Orders

Special-order products must be picked up within 30 days of purchase unless other arrangements have been approved.

Unclaimed special-order products may be returned to the manufacturer and may be subject to applicable restocking fees.

Contact Us

If you have questions regarding returns, refunds, or exchanges, please contact us:

HVAC Parts & Equipment Depot

Phone: (214) 734-5222
Email: support@tophvacparts.com

Michel & Siso are very knowledgeable and explain everything to where I could understand! Amazing experience! Thank you will always come here for any AC needs. Trustworthy and excellent customer service.

Celest G.
Verified Customer
View full details

Happy Shouts From Our Thrilled Customers

YOU MAY ALSO LIKE

Explore More Products

HVAC Parts and Equipment Depot

Frequently Asked Questions

Questions? We’ve got you covered

We are open to the public! Homeowners, landlords, and DIYers are all welcome—no license required.

We carry blower motors, fan motors, capacitors, control boards, contactors, thermostats, filters, copper lines, refrigerants, and more.

Yes, we stock OEM and compatible replacement parts for major brands including Trane, Goodman, Lennox, Carrier, Rheem, and others.

Absolutely! Bring in the part, model number, or a picture, and our team will help match you with the correct replacement.

Yes, we accept returns or exchanges within a set time period—just make sure the item is unused and in original packaging. Ask for specific terms at the counter.

While we don't install, we can answer basic questions and refer you to trusted local HVAC technicians if needed.

We sell certain refrigerants, but EPA regulations require certification for purchase of products like R-410A or R-22.

We offer both! You can shop in person or call to arrange shipping if you're out of town.