OEM Goodman-Amana Auto Limit Switch (120F - 130F) 0130F00038

OEM Goodman-Amana Auto Limit Switch (120F - 130F) 0130F00038

Low stock: 1 left

Regular price $19.99 USD
Regular price Sale price $19.99 USD
Sale Sold out
Shipping calculated at checkout.

OEM Goodman-Amana Auto Limit Switch (120F - 130F) 0130F00038

Please visit our store for pick up.

Quantity

safe & secure Checkout

Fast & Tracked Delivery
30 Day money back guarantee

Specifications

  • Voltage Rating: This switch operates on 120 VAC (Volts AC).
  • Current Rating: The specific amperage is not universally listed but is designed for standard control circuit loads.
  • Operation Type: It is an "auto-reset" type switch. When the temperature drops below the operating range, it automatically resets and closes the circuit.
  • Temperature Range: The switch is a "Limit Open On Rise" type:
  • Opens: (shuts off the furnace) at 130°F (degrees Fahrenheit).
  • Closes: (resets) at 120°F.

description

The code 0130F00038S identifies a specific Amana-Goodman automatic limit switch, a crucial safety component in HVAC systems that monitors internal temperatures, typically shutting off the heat if it exceeds the 120°F to 130°F range to prevent overheating and maintain safe operation. It's a genuine OEM replacement part, often light blue, designed for various Goodman, Amana, and compatible furnaces, ensuring efficient and safe heating. 


Key Characteristics:

  • Function: Acts as a safety device to prevent furnace overheating by cutting power.
  • Temperature Rating: Auto-opens between 120°F and 130°F.
  • Compatibility: Used in Goodman, Amana, and other HVAC systems.
  • Appearance: Often identified as light blue. 


What it does in your system:

When your furnace gets too hot, this switch detects the excess temperature and automatically cuts the fuel supply or shuts down the heating element, then resets once the system cools, protecting your equipment and ensuring safe indoor comfort. 


0130F00038S is a genuine OEM automatic reset primary limit switch (not a pressure switch as with previous parts). It functions as a safety device in Goodman, Amana, Janitrol, and Daikin HVAC systems to prevent overheating.


Electrical and Temperature Specifications:

  • Voltage Rating: This switch operates on 120 VAC (Volts AC).
  • Current Rating: The specific amperage is not universally listed but is designed for standard control circuit loads.
  • Operation Type: It is an "auto-reset" type switch. When the temperature drops below the operating range, it automatically resets and closes the circuit.
  • Temperature Range: The switch is a "Limit Open On Rise" type:
  • Opens: (shuts off the furnace) at 130°F (degrees Fahrenheit).
  • Closes: (resets) at 120°F.


The 0130F00038S limit switch replaces or is affiliated with the following part numbers:

  • 0130F00038
  • G0130F00038S
  • 42AL51
  • L45-224
  • 93358
  • P349572


This limit switch is used in many series of 80% and 90%+ AFUE furnaces across several brands. Below is a partial list of compatible series and examples:


Amana:

  • ACEC
  • ACES
  • ACSH
  • ACSS
  • ACVC
  • ACVM
  • ADSH
  • ADSS
  • ADVC
  • AMEC
  • AMEH
  • AMES
  • AMH
  • AMS
  • AMSS
  • AMVC
  • AMVM

Goodman:

  • GCEC
  • GCES
  • GCH
  • GCSS
  • GCVC
  • GCVM
  • GDH
  • GDS
  • GHS
  • GME
  • GMEC
  • GMES
  • GMH
  • GMS
  • GMSS
  • GMVC


GMVM Series:

  • GCEC800403AXAA
  • GCVC800805CXAA
  • GMEC800403ANAA
  • GMVC800805CNAA


Daikin DC, DD, DM Series:

  • DC80SE0403AXAA
  • DM80HS0403AXAA
  • DM96HS0402BNAA

This switch is generally compatible with any Goodman, Amana, Janitrol, or Daikin model requiring a primary limit switch that opens at 130°F and automatically resets.

Specification

Refund policy

Refund & Return Policy

Last Updated: June 2026

At HVAC Parts & Equipment Depot, customer satisfaction is important to us. This Refund & Return Policy explains how returns, exchanges, and refunds are handled for purchases made through TopHVACParts.com.

Return Eligibility

We accept returns within 30 days of delivery.

To qualify for a return:

  • The item must be unused, uninstalled, and in its original condition.
  • The item must be returned in its original packaging.
  • Model numbers and serial numbers must match the original purchase records.
  • Proof of purchase or order confirmation is required.

Non-Returnable Items

The following items are not eligible for return or refund:

  • Installed or used parts.
  • Products showing signs of installation, modification, or damage caused after delivery.
  • Items missing original packaging.
  • Sale or clearance items.
  • Special-order or custom-order products.
  • Returns requested more than 30 days after delivery.

Restocking Fee

Approved returns may be subject to a 20% restocking fee.

The restocking fee will be deducted from the refund amount after the returned item has been inspected and approved.

Damaged, Defective, or Incorrect Items

If you receive a damaged, defective, or incorrect item, please contact us within 7 days of delivery.

Email: support@tophvacparts.com
Phone: (214) 734-5222

We may request photographs and additional information to help process your claim.

If the claim is approved, we will provide a replacement, exchange, or refund at no additional cost to you.

Exchanges

We replace items only if they are defective, damaged upon arrival, or incorrectly shipped.

To request an exchange, contact us at:

support@tophvacparts.com

Refund Process

Once your return is received and inspected, we will notify you by email regarding approval or rejection of your refund request.

If approved:

  • Refunds will be issued to the original payment method.
  • Processing typically takes 7–14 business days after approval.
  • Your financial institution may require additional time before the refund appears in your account.

Return Shipping

Customers are responsible for return shipping costs unless the return is the result of:

  • Our shipping error,
  • A defective product,
  • A damaged product received upon delivery.

Original shipping charges are non-refundable.

We recommend using a trackable shipping service and purchasing shipping insurance for higher-value items.

Return Address

HVAC Parts & Equipment Depot
1135 E Plano Parkway, Suite 8
Plano, TX 75074
United States

Professional Installation Notice

Many HVAC products require installation by a licensed HVAC professional.

HVAC Parts & Equipment Depot is not responsible for damages resulting from improper installation, misuse, unauthorized modifications, or failure to follow manufacturer instructions.

Special Orders

Special-order products must be picked up within 30 days of purchase unless other arrangements have been approved.

Unclaimed special-order products may be returned to the manufacturer and may be subject to applicable restocking fees.

Contact Us

If you have questions regarding returns, refunds, or exchanges, please contact us:

HVAC Parts & Equipment Depot

Phone: (214) 734-5222
Email: support@tophvacparts.com

Michel & Siso are very knowledgeable and explain everything to where I could understand! Amazing experience! Thank you will always come here for any AC needs. Trustworthy and excellent customer service.

Celest G.
Verified Customer
View full details

Happy Shouts From Our Thrilled Customers

YOU MAY ALSO LIKE

Explore More Products

HVAC Parts and Equipment Depot

Frequently Asked Questions

Questions? We’ve got you covered

We are open to the public! Homeowners, landlords, and DIYers are all welcome—no license required.

We carry blower motors, fan motors, capacitors, control boards, contactors, thermostats, filters, copper lines, refrigerants, and more.

Yes, we stock OEM and compatible replacement parts for major brands including Trane, Goodman, Lennox, Carrier, Rheem, and others.

Absolutely! Bring in the part, model number, or a picture, and our team will help match you with the correct replacement.

Yes, we accept returns or exchanges within a set time period—just make sure the item is unused and in original packaging. Ask for specific terms at the counter.

While we don't install, we can answer basic questions and refer you to trusted local HVAC technicians if needed.

We sell certain refrigerants, but EPA regulations require certification for purchase of products like R-410A or R-22.

We offer both! You can shop in person or call to arrange shipping if you're out of town.