Michel & Siso are very knowledgeable and explain everything to where I could understand! Amazing experience! Thank you will always come here for any AC needs. Trustworthy and excellent customer service.

Celest G.
Verified Customer

4.9/5 based on 4750 reviews

Carrier Furnace Control Boards LH33WP002 Ignition Control Circuit Board

Carrier Furnace Control Boards LH33WP002 Ignition Control Circuit Board

Regular price $0.00 USD
Regular price Sale price $0.00 USD
Sale Sold out

Please visit our store for pick up.

Quantity

safe & secure Checkout

Fast & Tracked Delivery
30 Day money back guarantee

Specifications

description

Carrier Furnace Control Boards

Factory Authorized Parts™ - LH33WP002 Ignition Control Circuit Board

Factory Authorized Parts are designed to meet exact Carrier® Corporation specifications, ensuring optimum system performance, proven reliability, easy installation and maintenance and safe system operation.

Dimensions
Length 5.8 Inches (in)
Width 7.8 Inches (in)
Height 1.9 Inches (in)
Weight 0.45 Pounds (lbs)
Attributes
Brand RCD Parts
CSA Listing Yes
Country Of Origin MEX
Cubic Measurement 0.0497
Dimensional Weight 1
Prop 65 No
UOM EA
UPC Barcode 662441375538

Installation Instructions

1. Turn thermostat to OFF position or set it to the lowest possible setting.

2. Turn OFF electrical supply to furnace.

3. Turn OFF gas supply to furnace. CAUTION! Failure to turn off gas and electric supplies can result in explosion, fire, death, or personal injury.

4. For 80% furnaces, remove control access and blower door; for 90% furnaces, remove outer door assembly and remove the two screws from blower access panel and set aside.

5. Disconnect thermostat wires and humidifier wires (if equipped with a humidifier).

6. Disconnect line voltage, blower, electronic air cleaner wires (if equipped), and transformer wires.

7. For 80% furnaces, remove retaining screws and remove furnace control board from bracket; for 90% furnaces, remove two screws from blower deck that hold the control box assembly. Lower the control box assembly. Remove retaining screw(s) from board and remove board from control box assembly.

8. Remove wiring harness connectors from circuit board.

9. Examine control and control box to check for water stains.

10. Make repairs if any sources of water leakage are found. Be sure to check humidifiers, evaporator coils, and vent systems in the area of the control.

Step 2: Install the New Control

1. Ground yourself. When handling circuit board, hold it by the edges.

2. Insert tab(s) of board into the slots of the control box (if required).

3. Fasten circuit board with retaining screw(s). Install the included wiring harness adapter to the three connections of the existing furnace wiring harness. A. The furnace harness 9-pin connector plugs into the mating 9-pin adapter harness connector.

B. The furnace harness 2-pin connector plugs into the mating 2-pin adapter harness connector.

C. The furnace harness 3-pin connector plugs into the mating 3-pin adapter harness connector.

4. Connect the other end of the included adapter harness to the new furnace control board.

A. The 11-pin connector connects to PL1 on the furnace control board.

B. The 2-pin connector (with 2-black wires) connects to PL2 on the furnace control board.

C. The (2) white wires connect to the 115-volt Neutral spade connections located in front of PL1 on the new furnace control board.

System Tests Step 1: Component Self Test 1. Begin component test sequence by ensuring that thermostat is turned to OFF position and thermostat wires are disconnected. Turn power ON and manually close the blower door switch. With a short piece of wire, briefly short TEST/TWIN terminal to Com/24V terminal. The component test sequence follows:

A. Status LED will flash code and will then turn ON the inducer motor.

B. Inducer motor will run for the entire component test.

C. Hot surface ignitor will turn ON for 15 secs.

D. Blower motor heat speed will turn ON for 10 secs.

E. Blower motor cool speed will turn ON for 10 secs.

2. Repair, replace, or service any failing components from the component self test. The gas valve is not energized during the self test.

3. Turn power OFF.

4. Release the blower door switch. Twinning Instructions A 3/16” quick connect terminal is provided on the ICM282B control board for communication between another ICM282B control board for furnace twinning.

To configure your control boards for twinning:

1. Install each control board according to the installation instructions.

2. Connect the TWIN terminals together.

3. Connect the 24 VAC common together. (A common ground between the two furnaces is also required.) If the 24 VAC supplies to the control are in phase, both furnaces will turn the blower on and off synchronously and at the same speed. If the 24 VAC supplies are not in phase, then neither control will respond to the thermostat commands and the status LED will flash rapidly.

Specification

Refund policy

Our refund and returns policy lasts 30 days. If 30 days have passed since your purchase, we can’t offer you a full refund or exchange. Please note there will be a 20% Re-stocking fee of product price.
To be eligible for a return, your item must be unused and in the same condition that you received it. It must also be in the original packaging. Model and serial number must match what is on the invoice and correct box information.
Exclusions:
•    Part with obvious signs of use of installation.
•    Original box was destroyed or could not be located by purchaser.
•    Any item not in its original condition, is damaged or missing parts for reasons not due to our error.
•    Any item that is returned more than 30 days after delivery
Part installation
HVAC Parts and Equipment Depot recommend this parts will be installed by a licensed professional contractor. HVAC Parts and Equipment Depot assumes no liability for any injuries or damages arising from the user information or products. 
Sale items
Only regular priced items may be refunded. Sale items cannot be refunded. Special Order items cannot be refunded. 
Exchanges
We only replace items if they are defective or damaged from Manufactory. If you need to exchange it for the same item, send us an email at hvacpartsstore@gmail.com and send your item to: HVAC Parts & Equipment Depot 1135 E Plano Parkway Suite 8 Plano Tx 75189.
Refunds
To complete your return, we require a receipt or proof of purchase within 30 days or less.
Once your return is received and inspected by management team, we will send you an email to notify you that we have received your returned item. We will also notify you of the approval or rejection of your refund.
If you are approved, then your refund will be processed, and a credit will automatically be applied to your credit card or original method of payment, within 7-14 Business days. HVAC Parts and Equipment Depot or its employees are not responsible for damaged items from manufactory.
Shipping returns
To return your product, you should mail your product to:
HVAC Parts & Equipment Depot
1135 E Plano Parkway Suite 8 Plano Tx 75074.
Customer will be responsible for paying for shipping. Shipping costs are non-refundable. If you receive a refund, the cost of return shipping will be deducted from your refund.
Depending on where you live, the time it may take for your exchanged product to reach you may vary.
If you are returning more expensive items, you may consider using a trackable shipping service or purchasing shipping insurance. We don’t guarantee that we will receive your returned item without a valid tracking number provided by your choice of delivery method.
Late or missing refunds
If you haven’t received a refund yet, first check your bank account again. This process takes approximately 7-14 business days depending on your Bank.
Then contact your credit card company, it may take some time before your refund is officially posted.
Next contact your bank. There is often some processing time before a refund is posted.
If you’ve done all of this and you still have not received your refund yet, please contact us at hvacpartsstore@gmail.com
Special Orders
Special orders should be picked up within 30 Days of purchase day. Your items will be considered abandoned and will be returned to manufacturer. There will be a 100% Re-stocking fee for abandoned items. 

Need help?
Contact us via email hvacpartsstore@gmail.com or Phone 214-734-5222 for questions related to refunds and returns.
Thank you for choosing HVAC Parts & Equipment Depot.

Michel & Siso are very knowledgeable and explain everything to where I could understand! Amazing experience! Thank you will always come here for any AC needs. Trustworthy and excellent customer service.

Celest G.
Verified Customer
View full details

Happy Shouts From Our Thrilled Customers

YOU MAY ALSO LIKE

Explore More Products

HVAC Parts and Equipment Depot

Frequently Asked Questions

Questions? We’ve got you covered

We are open to the public! Homeowners, landlords, and DIYers are all welcome—no license required.

We carry blower motors, fan motors, capacitors, control boards, contactors, thermostats, filters, copper lines, refrigerants, and more.

Yes, we stock OEM and compatible replacement parts for major brands including Trane, Goodman, Lennox, Carrier, Rheem, and others.

Absolutely! Bring in the part, model number, or a picture, and our team will help match you with the correct replacement.

Yes, we accept returns or exchanges within a set time period—just make sure the item is unused and in original packaging. Ask for specific terms at the counter.

While we don't install, we can answer basic questions and refer you to trusted local HVAC technicians if needed.

We sell certain refrigerants, but EPA regulations require certification for purchase of products like R-410A or R-22.

We offer both! You can shop in person or call to arrange shipping if you're out of town.