{"product_id":"lennox-ecba25-15cb-15-kw-electric-heat-kit-with-circuit-breaker-208-240v-1-ph-cat-16y44-oem-replacement","title":"Lennox ECBA25-15CB 15 kW Electric Heat Kit with Circuit Breaker 208-240V 1 Ph Cat # 16Y44 OEM Replacement","description":"\u003ch1\u003eLennox ECBA25-15CB 15 kW Electric Heat Kit with Circuit Breaker 208-240V 1 Ph Cat # 16Y44 OEM Replacement\u003c\/h1\u003e\n\u003cp\u003eThe Lennox ECBA25-15CB (Cat # 16Y44) is a high-capacity electric emergency heat kit, acting as the critical thermal \"brain\" for your indoor air handler during extreme cold weather or primary heat pump failure. This 15 kW heating assembly is specifically engineered to provide supplemental or primary warmth, functioning as the system's safety monitor for indoor comfort. Designed for Lennox and Allied Air handler series, the ECBA25-15CB features factory-installed circuit breakers that serve as the primary electrical gateway, protecting the internal heating elements and the home's wiring from overcurrent. By utilizing this genuine OEM heat kit, you ensure your air handler maintains its factory-certified airflow and safety ratings while providing instantaneous, reliable backup heat. \u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenuine OEM Part Number ECBA25-15CB (Cat # 16Y44):\u003c\/strong\u003e Guaranteed factory-direct fit for Lennox CBA25UH and CBA27UHE air handlers, eliminating the need for field-drilled mounting holes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Output 15 kW Heating Capacity:\u003c\/strong\u003e Specifically engineered with heavy-duty nickel-chromium coils to deliver robust supplemental heat for large residential spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Circuit Breaker Protection:\u003c\/strong\u003e Features a built-in dual-pole circuit breaker that eliminates the need for an external disconnect and provides an extra layer of electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEliminate Relay and Sequencing Issues:\u003c\/strong\u003e Replaces aging or burnt heating elements that cause \"cold blows\" or failed emergency heat cycles during defrost mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Thermal Limit Monitoring:\u003c\/strong\u003e Equipped with high-temperature automatic reset limits to prevent the air handler cabinet from overheating if airflow is restricted. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Details\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Lennox \/ Allied Air\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Lennox Industries\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e ECBA25-15CB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog Number (Cat #):\u003c\/strong\u003e 16Y44\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Capacity:\u003c\/strong\u003e 15 kW (Kilowatts)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 208-240 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e 1 Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Protection:\u003c\/strong\u003e Integrated Circuit Breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat Stages:\u003c\/strong\u003e Multi-Stage Capable (Sequenced)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 11.2 lbs \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e🛠️ HVAC Depot Pro Tip\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eTake a Picture First —\u003c\/strong\u003e Before sliding the ECBA25-15CB into the air handler's heater pocket, photograph the internal plug-and-play wiring harness. Lennox units use a specific multi-pin connector; having a visual record confirms that the pins are seated correctly and haven't pushed out during the diagnostic check. When installing, ensure the heater is pushed fully into the cabinet to engage the mounting clips; a loose heater can vibrate, leading to mechanical noise or shorted elements. Always verify that your thermostat is configured for \"Electric Heat\" to ensure the blower motor engages the moment the heat kit is energized.\u003c\/p\u003e\n\u003ch2\u003eCross-Reference\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuperseded Parts:\u003c\/strong\u003e 10M54, 16Y4401, ECBA25-15, 613524-03\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLegacy Drawing Numbers:\u003c\/strong\u003e 1012-920, 18H51, 614234-03\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent Brands:\u003c\/strong\u003e Allied Air 16Y44, Concord 16Y44, Ducane 16Y44, AirEase 16Y44\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eModel Compatibility\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCBA25UH\u003c\/strong\u003e (Suffixes: 018, 024, 030, 036, 042, 048, 060)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCBA27UHE\u003c\/strong\u003e (Suffixes: 018, 024, 030, 036, 042, 048, 060)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBCE5\u003c\/strong\u003e (Suffixes: 18, 24, 30, 36, 42, 48, 60)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBCE7\u003c\/strong\u003e (Suffixes: 18, 24, 30, 36, 42, 48, 60)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCBA38MV\u003c\/strong\u003e (Suffixes: 018, 024, 030, 036, 042, 048, 060) \u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lennox","offers":[{"title":"Default Title","offer_id":52451496886635,"sku":"662551169442","price":240.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/ECBA25-15CB.jpg?v=1762813620","url":"https:\/\/tophvacparts.com\/products\/lennox-ecba25-15cb-15-kw-electric-heat-kit-with-circuit-breaker-208-240v-1-ph-cat-16y44-oem-replacement","provider":"HVAC Parts and Equipment Depot Open To Homeowners and Contractors","version":"1.0","type":"link"}