{"product_id":"lennox-72w34-103016-01-honeywell-vr9205r2363-oem-modulating-natural-gas-valve-24-vac-1-2-x-1-2-3-5-wc","title":"Lennox 72W34 \/ 103016-01 Honeywell VR9205R2363 OEM Modulating Natural Gas Valve – 24 VAC, 1\/2\" x 1\/2\", 3.5\" WC","description":"\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eLennox 72W34\u003c\/b\u003e, model\/part \u003cb\u003e103016-01\u003c\/b\u003e, is an OEM \u003cb\u003eHoneywell VR9205R2363 modulating natural gas valve\u003c\/b\u003e designed for select Lennox gas-fired heating equipment.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eUnlike a standard single-stage or two-stage gas valve, this \u003cb\u003emodulating valve\u003c\/b\u003e adjusts gas flow in response to the furnace control system. This allows compatible modulating furnaces to vary heating output more precisely according to demand for improved temperature control and system operation.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe valve operates on \u003cb\u003e24 VAC\u003c\/b\u003e, uses \u003cb\u003e1\/2\" x 1\/2\" gas connections\u003c\/b\u003e, and has a maximum regulator setting of \u003cb\u003e3.5 ±0.3 inches W.C.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features \u0026amp; Function\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eGenuine \u003cb\u003eLennox OEM\u003c\/b\u003e replacement component\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eManufactured by \u003cb\u003eHoneywell\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eCat #: 72W34\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eLennox Part #: 103016-01\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eHoneywell Model: VR9205R2363\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eModulating gas valve\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for \u003cb\u003enatural gas\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e24 VAC\u003c\/b\u003e operation\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e1\/2\" x 1\/2\"\u003c\/b\u003e gas connections\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eMaximum regulator setting: \u003cb\u003e3.5 ±0.3\" W.C.\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eProvides variable gas-flow control\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eWorks with compatible modulating furnace controls\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eAdjusts burner input according to heating demand\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for select Lennox modulating gas furnaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Details \u0026amp; Key Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eBrand\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eLennox\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eValve Manufacturer\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHoneywell\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCatalog Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e72W34\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eLennox Part Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e103016-01\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eHoneywell Model\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eVR9205R2363\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eModulating Gas Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eFuel Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eNatural Gas\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eVoltage\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e24 VAC\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eControl Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eModulating\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eInlet Connection\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e1\/2\"\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eOutlet Connection\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e1\/2\"\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 12;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eConnection Configuration\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e1\/2\" x 1\/2\"\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 13;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eMaximum Regulator Setting\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e3.5 ±0.3\" W.C.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 14;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eApplication\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eModulating Gas Furnace\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 15;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eFunction\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVariable Burner Gas-Flow Control\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 16; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eOEM Component\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Segoe UI Emoji',sans-serif; mso-bidi-font-family: 'Segoe UI Emoji';\"\u003e🛠️\u003c\/span\u003e HVAC Depot Pro Tip\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003e72W34 \/ 103016-01 is a modulating gas valve\u003c\/b\u003e, which is an important distinction when selecting a replacement.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eDo \u003cb\u003enot\u003c\/b\u003e substitute a standard single-stage or two-stage 24V gas valve simply because the pipe size and voltage are the same.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eMatch:\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCatalog Number: 72W34\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eLennox Part Number: 103016-01\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eHoneywell Number: VR9205R2363\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eFuel: Natural Gas\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eVoltage: 24 VAC\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eControl: Modulating\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eConnections: 1\/2\" x 1\/2\"\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eMax Regulator Setting: 3.5 ±0.3\" W.C.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe furnace control system must be designed to operate this specific type of modulating valve.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eGas-valve replacement should include leak testing, inlet and manifold gas-pressure verification, ignition testing, modulation testing, and combustion analysis according to the equipment manufacturer's procedures and applicable codes.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment \/ Model Compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eLennox 72W34 \/ 103016-01\u003c\/b\u003e is designed for select \u003cb\u003eLennox modulating gas furnaces\u003c\/b\u003e requiring the Honeywell \u003cb\u003eVR9205R2363\u003c\/b\u003e gas valve.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eTypical applications include:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eSelect Lennox modulating furnaces\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eVariable-capacity gas heating equipment\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eNatural-gas furnace applications\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003e24 VAC modulating gas-control systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eEquipment specifically calling for \u003cb\u003e72W34\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eEquipment specifically calling for \u003cb\u003e103016-01\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eApplications requiring \u003cb\u003eVR9205R2363\u003c\/b\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eAlways verify the complete furnace \u003cb\u003emodel and serial number\u003c\/b\u003e before ordering.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Lennox","offers":[{"title":"Default Title","offer_id":53977545245035,"sku":"66255142290","price":341.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/72W34.jpg?v=1790962348","url":"https:\/\/tophvacparts.com\/products\/lennox-72w34-103016-01-honeywell-vr9205r2363-oem-modulating-natural-gas-valve-24-vac-1-2-x-1-2-3-5-wc","provider":"HVAC Parts and Equipment Depot Open To Homeowners and Contractors","version":"1.0","type":"link"}