{"product_id":"icm856-ptcr-hard-start-kit-130-156-mfd-115-288-vac-1-2-to-10-hp","title":"ICM856 PTCR Hard Start Kit – 130-156 MFD, 115-288 VAC, 1\/2 to 10 HP","description":"\u003ch1 class=\"MsoNormal\"\u003e\u003cb\u003eICM Controls ICM856 PTCR Hard Start Kit – 130-156 MFD, 115-288 VAC, 1\/2 to 10 HP\u003c\/b\u003e\u003c\/h1\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eICM Controls ICM856 PTCR Hard Start Kit\u003c\/b\u003e is a high-performance aftermarket motor starting device designed to improve compressor starting torque in residential and light commercial air conditioning and heat pump systems. Utilizing Positive Temperature Coefficient (PTC) technology, the ICM856 helps reduce compressor startup stress, minimizes voltage drop during startup, and extends compressor life by delivering additional starting torque when it is needed most. It is recommended for compressors ranging from \u003cb\u003e1\/2 HP to 10 HP\u003c\/b\u003e, with optimal performance in \u003cb\u003e2 to 5 HP\u003c\/b\u003e applications.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eICM856\u003c\/b\u003e features a \u003cb\u003e130-156 MFD start capacitor\u003c\/b\u003e, operates on \u003cb\u003e115-288 VAC\u003c\/b\u003e, and installs quickly with a simple two-wire connection. Designed as a cost-effective replacement for several popular hard start kits, it provides up to \u003cb\u003e500% increased starting torque\u003c\/b\u003e, making it an excellent solution for aging compressors, low-voltage conditions, and systems experiencing hard starting.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features and Function\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003eIncreases Starting Torque up to 500%\u003c\/b\u003e – Helps compressors start quickly and efficiently under difficult conditions.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003ePTCR Technology\u003c\/b\u003e – Positive Temperature Coefficient relay automatically removes the start capacitor from the circuit after startup.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003eUniversal Two-Wire Installation\u003c\/b\u003e – Fast and easy installation without additional relays.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003eExtends Compressor Life\u003c\/b\u003e – Reduces startup stress and electrical strain.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003eIdeal for Hard Starting Compressors\u003c\/b\u003e – Excellent for older systems and low-voltage applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Details and Key Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo2; tab-stops: list .5in;\"\u003e\n\u003cb\u003ePart Number:\u003c\/b\u003e ICM856\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo2; tab-stops: list .5in;\"\u003e\n\u003cb\u003eManufacturer:\u003c\/b\u003e ICM Controls\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo2; tab-stops: list .5in;\"\u003e\n\u003cb\u003ePart Type:\u003c\/b\u003e PTCR Hard Start Kit\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo2; tab-stops: list .5in;\"\u003e\n\u003cb\u003eCapacitor Rating:\u003c\/b\u003e 130-156 MFD\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo2; tab-stops: list .5in;\"\u003e\n\u003cb\u003eMaximum Capacitor Voltage:\u003c\/b\u003e 330 VAC\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo2; tab-stops: list .5in;\"\u003e\n\u003cb\u003eOperating Voltage:\u003c\/b\u003e 115-288 VAC\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo2; tab-stops: list .5in;\"\u003e\n\u003cb\u003eHorsepower Range:\u003c\/b\u003e 1\/2 HP to 10 HP\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo2; tab-stops: list .5in;\"\u003e\n\u003cb\u003eRecommended Range:\u003c\/b\u003e 2 HP to 5 HP\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo2; tab-stops: list .5in;\"\u003e\n\u003cb\u003eNumber of Wires:\u003c\/b\u003e 2\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo2; tab-stops: list .5in;\"\u003e\n\u003cb\u003eRelay Type:\u003c\/b\u003e Positive Temperature Coefficient (PTCR)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo2; tab-stops: list .5in;\"\u003e\n\u003cb\u003eApplication:\u003c\/b\u003e Air Conditioners, Heat Pumps, Refrigeration Equipment\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo2; tab-stops: list .5in;\"\u003e\n\u003cb\u003eDimensions:\u003c\/b\u003e Approximately 5.75\" H × 2.38\" W × 2.00\" D\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo2; tab-stops: list .5in;\"\u003e\n\u003cb\u003eShipping Weight:\u003c\/b\u003e Approximately 0.55 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Segoe UI Emoji',sans-serif; mso-bidi-font-family: 'Segoe UI Emoji';\"\u003e🛠️\u003c\/span\u003e HVAC Depot Pro Tip: Hard Starting Compressor?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIf your compressor struggles to start, especially during hot weather or under low-voltage conditions, installing a hard start kit like the \u003cb\u003eICM856\u003c\/b\u003e can significantly reduce startup amperage and improve compressor reliability. Always verify that the compressor itself is mechanically sound before installing a hard start kit.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCross-Reference \u0026amp; Compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eICM856\u003c\/b\u003e directly replaces several popular PTCR hard start kits.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eOEM \/ Cross References:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eA-1 Components: \u003cb\u003eWXS-6\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eMARS: \u003cb\u003e32702\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eMARS: \u003cb\u003e35702\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eSupco: \u003cb\u003eSPP-6\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eWagner \/ DiversiTech: \u003cb\u003eDST-6\u003c\/b\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eExtensive Model Compatibility List\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eCompatible with most residential and light commercial:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo4; tab-stops: list .5in;\"\u003eAir Conditioning Systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo4; tab-stops: list .5in;\"\u003eHeat Pump Systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo4; tab-stops: list .5in;\"\u003eRefrigeration Equipment\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo4; tab-stops: list .5in;\"\u003eScroll Compressors\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo4; tab-stops: list .5in;\"\u003eReciprocating Compressors\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo4; tab-stops: list .5in;\"\u003eRotary Compressors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eSupports compressors from \u003cb\u003e1\/2 HP through 10 HP\u003c\/b\u003e, with best performance on \u003cb\u003e2-5 HP\u003c\/b\u003e systems. Always verify compressor specifications before installation.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"ICM","offers":[{"title":"Default Title","offer_id":53664023118187,"sku":"ICM856","price":40.86,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/ICM856.jpg?v=1785871648","url":"https:\/\/tophvacparts.com\/products\/icm856-ptcr-hard-start-kit-130-156-mfd-115-288-vac-1-2-to-10-hp","provider":"HVAC Parts and Equipment Depot Open To Homeowners and Contractors","version":"1.0","type":"link"}