{"product_id":"icm-controls-goodman-fan-blower-replacement-control-board-18-30-vac","title":"ICM Controls | Goodman Fan Blower Replacement Control Board | 18-30 VAC","description":"\u003cdiv class=\"n6owBd awi2gc\"\u003e\n\u003ch1 class=\"n6owBd awi2gc\"\u003e\n\u003cstrong class=\"rQesXe MPyX\"\u003eICM Controls ICM277C Fan Blower Control Board 18-30 VAC\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/h1\u003e\n\u003cdiv class=\"Fsg96\"\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/div\u003e\n\u003cdiv class=\"otQkpb\" role=\"heading\"\u003e\n\u003cbr\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"n6owBd awi2gc\"\u003eThe \u003cstrong class=\"rQesXe MPyX\"\u003eICM Controls ICM277C\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e is an engineered, original equipment manufacturer (OEM) replacement fan blower control board designed for forced-air systems, air conditioners, and heat pumps. This microprocessor-based module governs duct sequencing and airflow distribution by establishing precise timed-activation cycles for the circulating indoor fan.\u003c!--TgQPHd|||[]--\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"n6owBd awi2gc\"\u003eThe module acts as a dedicated relay interface that communicates with standard low-voltage 24V thermostat signals. It monitors system safety switches while ensuring optimal energy efficiency during standard thermal demands. Designed as a direct swap for failing legacy fan centers, it supports specialized residential gas furnace and air handler series from Goodman, Amana, Carrier, and Bryant, eliminating timing discrepancies across multi-speed motor taps.\u003c!--TgQPHd|||[]--\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"n6owBd awi2gc\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"Fsg96\"\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/div\u003e\n\u003ch2 class=\"otQkpb\" role=\"heading\"\u003eKey Features\u003c!--TgQPHd|||[]--\u003e\n\u003c\/h2\u003e\n\u003cul class=\"KsbFXc U6u95\"\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"iNqyIf\"\u003e\u003cstrong class=\"rQesXe MPyX\"\u003eDirect Form Factor Part Match:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Tailored to fulfill exact physical constraints under part number \u003cstrong class=\"rQesXe MPyX\"\u003eICM277C\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e, aligning seamlessly with original factory board layouts and electrical terminals.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"iNqyIf\"\u003e\u003cstrong class=\"rQesXe MPyX\"\u003eBroad OEM Specification Fit:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Formulated to serve as a low-cost, wire-for-wire alternative replacing Goodman B1370735S, PCBFM103S, and Carrier CES0110017\/18 series control modules without needing ductwork or cabinet modification.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"iNqyIf\"\u003e\u003cstrong class=\"rQesXe MPyX\"\u003eNoise Mitigation \u0026amp; Relay Upgrades:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Equipped with heavy-duty dual function inductive relays rated up to 20 Amps, permanently silencing clicking relay chatter, erratic motor humming, and voltage-induced line noise.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"iNqyIf\"\u003e\u003cstrong class=\"rQesXe MPyX\"\u003eAdvanced Voltage \u0026amp; Safety Upgrades:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Replaces aged fan timers to restore structural security by implementing strict 7-second on-delays and 65-second off-delays alongside built-in safety circuit fuse protection to prevent system overheating.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd|||[]--\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"Fsg96\"\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/div\u003e\n\u003ch2 class=\"otQkpb\" role=\"heading\"\u003eProduct Details\u003c!--TgQPHd|||[]--\u003e\n\u003c\/h2\u003e\n\u003cul class=\"KsbFXc U6u95\"\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"iNqyIf\"\u003e\u003cstrong class=\"rQesXe MPyX\"\u003eBrand:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e ICM Controls\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"iNqyIf\"\u003e\u003cstrong class=\"rQesXe MPyX\"\u003eManufacturer:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e ICM Controls\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"iNqyIf\"\u003e\u003cstrong class=\"rQesXe MPyX\"\u003ePart # \/ MPN:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e ICM277C\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"iNqyIf\"\u003e\u003cstrong class=\"rQesXe MPyX\"\u003eUPC \/ SKU:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e 602594611413\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"iNqyIf\"\u003e\u003cstrong class=\"rQesXe MPyX\"\u003eShipping Weight:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e 0.60 lbs\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"iNqyIf\"\u003e\u003cstrong class=\"rQesXe MPyX\"\u003eControl Voltage Range:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e 18 to 30 VAC\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"iNqyIf\"\u003e\u003cstrong class=\"rQesXe MPyX\"\u003eInput Power Voltage:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e 18 to 30 VAC\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"iNqyIf\"\u003e\u003cstrong class=\"rQesXe MPyX\"\u003eNormally Open (N.O.) Contact Rating:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e 20 Amps\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"iNqyIf\"\u003e\u003cstrong class=\"rQesXe MPyX\"\u003eNormally Closed (N.C.) Contact Rating:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e 10 Amps\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"iNqyIf\"\u003e\u003cstrong class=\"rQesXe MPyX\"\u003eBlower On Time Delay:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e 7 Seconds\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"iNqyIf\"\u003e\u003cstrong class=\"rQesXe MPyX\"\u003eBlower Off Time Delay:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e 65 Seconds\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"iNqyIf\"\u003e\u003cstrong class=\"rQesXe MPyX\"\u003eMaximum Relative Operating Humidity:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e 95% Non-condensing\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"iNqyIf\"\u003e\u003cstrong class=\"rQesXe MPyX\"\u003eCountry of Origin:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e United States\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd|||[]--\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"Fsg96\"\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/div\u003e\n\u003ch2 class=\"otQkpb\" role=\"heading\"\u003e🛠️ HVAC Depot Pro Tip\u003c!--TgQPHd|||[]--\u003e\n\u003c\/h2\u003e\n\u003cdiv class=\"n6owBd awi2gc\"\u003e\n\u003cstrong class=\"rQesXe MPyX\"\u003eTake a Picture First!\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Prior to disconnecting any low-voltage thermostat lines or motor speed leads from the G, Y, or transformer terminals, record a clear visual layout of the existing wire orientation. Disconnect all primary building electrical power to the indoor handler center before handling the module to safeguard the solid-state microprocessor against electrostatic damage. Ensure that the integrated protection fuse is seated firmly in its socket during mounting, and verify that all wire crimp connections are locked tight to prevent high-resistance localized heating or premature circuit faults.\u003c!--TgQPHd|||[]--\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"n6owBd awi2gc\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"Fsg96\"\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/div\u003e\n\u003ch2 class=\"otQkpb\" role=\"heading\"\u003eCross-Reference\u003c!--TgQPHd|||[]--\u003e\n\u003c\/h2\u003e\n\u003cul class=\"KsbFXc U6u95\"\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"iNqyIf\"\u003e\u003cstrong class=\"rQesXe MPyX\"\u003eSuperseded \/ Legacy Goodman Models:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e B1370735, B1370735S, PCBFM103, PCBFM103S, 0130F00005S\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"iNqyIf\"\u003e\u003cstrong class=\"rQesXe MPyX\"\u003eSuperseded \/ Legacy Carrier Models:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e CES0110017, CES0110018, HH84AA-017, HH84AA-018\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"iNqyIf\"\u003e\u003cstrong class=\"rQesXe MPyX\"\u003eWhite-Rodgers \/ Emerson Equivalents:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e 50A50-110, 50A55-843 (Fan Timer Configurations)\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd|||[]--\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"Fsg96\"\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/div\u003e\n\u003ch2 class=\"otQkpb\" role=\"heading\"\u003eModel Compatibility\u003c!--TgQPHd|||[]--\u003e\n\u003c\/h2\u003e\n\u003cul class=\"KsbFXc U6u95\"\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"iNqyIf\"\u003e\u003cstrong class=\"rQesXe MPyX\"\u003eGMP\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e (Suffixes: 050-3, 075-3, 075-4, 100-3, 100-4, 125-5)\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"iNqyIf\"\u003e\u003cstrong class=\"rQesXe MPyX\"\u003eGMPN\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e (Suffixes: 040-3, 060-3, 080-4, 100-4)\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\n\u003cspan class=\"iNqyIf\"\u003e\u003cstrong class=\"rQesXe MPyX\"\u003eARUF\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e (Suffixes: 018-1, 024-1, 030-1, 032-1, 036-1, 042-1)\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\"\u003e\u003cspan class=\"iNqyIf\"\u003e\u003cstrong class=\"rQesXe MPyX\"\u003eGMNPE\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e (Suffixes: 060-3, 080-4, 100-5)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"ICM","offers":[{"title":"Default Title","offer_id":53673139470699,"sku":"ICM277C","price":88.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/ICM277.jpg?v=1786037531","url":"https:\/\/tophvacparts.com\/products\/icm-controls-goodman-fan-blower-replacement-control-board-18-30-vac","provider":"HVAC Parts and Equipment Depot Open To Homeowners and Contractors","version":"1.0","type":"link"}