{"product_id":"honeywell-home-t6-pro-th6220u2000-programmable-thermostat-2-heat-1-cool-24v-auto-manual-changeover-heating-cooling-control","title":"Honeywell Home T6 Pro TH6220U2000 Programmable Thermostat – 2 Heat \/ 1 Cool, 24V, Auto\/Manual Changeover, Heating \u0026 Cooling Control","description":"\u003cp class=\"MsoNormal\"\u003eThe Honeywell Home T6 Pro TH6220U2000 Programmable Thermostat is a professional-grade HVAC temperature control designed for compatible residential and light commercial heating and cooling systems.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eManufactured under the Honeywell Home brand by Resideo, the TH6220U2000 provides programmable temperature management for conventional and heat pump applications. Its digital display and intuitive controls allow homeowners to adjust indoor temperatures and customize heating and cooling schedules.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFeaturing support for up to 2 heating stages and 1 cooling stage, this thermostat provides flexible temperature control for compatible multistage HVAC equipment.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Honeywell TH6220U2000 supports automatic and manual heating\/cooling changeover, allowing the thermostat to switch operating modes automatically when properly configured or letting users select the desired mode manually.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWith a specified temperature control range of 37°F to 102°F, the T6 Pro offers dependable temperature management for approved heating and cooling applications.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eDesigned for professional installation, this programmable thermostat provides a practical replacement or upgrade for compatible 24-volt HVAC systems.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features \u0026amp; Function\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eBrand: Honeywell Home \/ Resideo\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eManufacturer Part Number: TH6220U2000\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eProduct Series: T6 Pro\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eProgrammable digital HVAC thermostat\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eHeating Stages: Up to 2\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eCooling Stages: Up to 1\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eTemperature Range: 37°F to 102°F\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eAutomatic and manual heating\/cooling changeover\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eSupports compatible conventional heating and cooling systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eSupports approved heat pump applications\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eProgrammable temperature scheduling\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eDigital temperature display\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eAdjustable temperature setpoints\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eInstaller setup options for system configuration\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eCompatible with standard low-voltage HVAC controls\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for residential and light commercial applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Details \u0026amp; Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eManufacturer\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eResideo\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eBrand\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHoneywell Home\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eManufacturer Part Number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eTH6220U2000\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eProduct Series\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eT6 Pro\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eProduct Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eProgrammable HVAC Thermostat\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHeating Application\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHeating \u0026amp; Cooling\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eMaximum Heating Stages\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eMaximum Cooling Stages\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eStage Configuration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e2H\/1C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eTemperature Range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e37°F to 102°F (2.8°C to 38.9°C)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eSystem Control\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eAutomatic\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 12;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eChangeover\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eAutomatic \/ Manual\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 13;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eProgramming\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eProgrammable Scheduling\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 14;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eDisplay Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eDigital\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 15;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eSystem Compatibility\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eCompatible Conventional \u0026amp; Heat Pump Systems\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 16;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eOperating Voltage\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e24 VAC HVAC Control\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 17;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003ePower Options\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e24 VAC or Battery Power, Configuration-Dependent\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 18;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eMounting Style\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eWall Mount\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 19;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eWi-Fi Connectivity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eNo\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 20;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eEquipment Application\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eCompatible Low-Voltage HVAC Systems\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 21; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eInstallation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eQualified HVAC Technician Recommended\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003eSpecification Note: The 2H\/1C configuration and 37°F–102°F range are based on the supplied product information. Supported heating and cooling stages depend on whether the thermostat is configured for a conventional system or a heat pump.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eHVAC Depot Pro Tip\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBefore installing the Honeywell Home TH6220U2000, confirm that the thermostat's stage configuration matches the connected HVAC equipment.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eA thermostat with insufficient heating or cooling stages may prevent a multistage system from operating as designed.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eRecommended installation checks:\u003c\/p\u003e\n\u003col style=\"margin-top: 0in;\" start=\"1\" type=\"1\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eConfirm the HVAC equipment model and control configuration.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eVerify the system uses compatible 24-volt thermostat controls.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eIdentify the existing thermostat wiring before removal.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eConfirm the required heating and cooling stages.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eCheck whether the system is conventional or heat pump.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eConfigure automatic or manual changeover as required.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eProgram the desired temperature schedule.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eTest heating and cooling operation after installation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"MsoNormal\"\u003eHVAC Depot Pro Tip: The TH6220U2000 is a programmable thermostat, not a Wi-Fi smart thermostat. It is a good choice for customers who want scheduling and digital temperature control without requiring an internet connection or smartphone app.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eImportant: Disconnect HVAC system power before thermostat installation. Incorrect wiring or configuration may damage the thermostat or equipment control board.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment \/ Model Compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Honeywell Home T6 Pro TH6220U2000 is designed for compatible low-voltage heating and cooling systems.\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eHVAC System Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCompatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eConventional Gas Furnace\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eCompatible with supported configurations\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eElectric Heating Systems\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eCompatible with supported configurations\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eCentral Air Conditioning\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eCompatible\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eSingle-Stage Heating \u0026amp; Cooling\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eCompatible\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eTwo-Stage Conventional Heating\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eCompatible\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eSingle-Stage Conventional Cooling\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eCompatible\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHeat Pump Systems\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eCompatible with supported configurations\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHeat Pump with Auxiliary Heat\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify stage and wiring requirements\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eDual-Fuel Systems\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify equipment and control configuration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eProprietary Communicating Systems\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eNot directly compatible\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eLine-Voltage Electric Heating\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eNot directly compatible\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003eCompatibility Notice: TH6220U2000 is designed for compatible low-voltage HVAC control systems. Verify thermostat wiring, equipment staging, and control requirements before purchasing.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":54164556415339,"sku":"TH6220U2000","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/TH6220U2000.jpg?v=1792595161","url":"https:\/\/tophvacparts.com\/products\/honeywell-home-t6-pro-th6220u2000-programmable-thermostat-2-heat-1-cool-24v-auto-manual-changeover-heating-cooling-control","provider":"HVAC Parts and Equipment Depot Open To Homeowners and Contractors","version":"1.0","type":"link"}