{"product_id":"goodman-amana-0151f00000ps-gas-valve-genuine-oem-2-stage-regulator-manifold-gas-valve","title":"Goodman-Amana 0151F00000PS Gas Valve – Genuine OEM 2-Stage Regulator Manifold Gas Valve","description":"\u003ch1 data-start=\"93\" data-end=\"476\"\u003eGoodman-Amana 0151F00000PS Gas Valve – Genuine OEM 2-Stage Regulator Manifold Gas Valve\u003c\/h1\u003e\n\u003cp data-start=\"93\" data-end=\"476\"\u003eThe Goodman-Amana 0151F00000PS Gas Valve is a genuine OEM 2-stage gas valve engineered for precise gas flow control and reliable furnace heating performance in residential HVAC systems. Designed with integrated regulator manifold functionality, this gas valve helps maintain safe ignition sequencing, proper burner operation, and efficient fuel delivery throughout the heating cycle.\u003c\/p\u003e\n\u003cp data-start=\"478\" data-end=\"844\"\u003eBuilt to OEM specifications for exact fitment and dependable operation, the 0151F00000PS gas valve provides accurate low-fire and high-fire stage control to improve comfort, heating efficiency, and furnace reliability. Its heavy-duty construction and factory-calibrated design ensure safe and stable gas pressure regulation for Goodman and Amana gas furnace systems.\u003c\/p\u003e\n\u003chr data-start=\"846\" data-end=\"849\"\u003e\n\u003ch2 data-section-id=\"1ybcqkm\" data-start=\"851\" data-end=\"880\"\u003eKey Features and Function:\u003c\/h2\u003e\n\u003cp data-start=\"882\" data-end=\"1286\"\u003e• \u003cstrong data-start=\"884\" data-end=\"913\"\u003e2-Stage Heating Operation\u003c\/strong\u003e – Provides low-fire and high-fire gas flow control for improved comfort\u003cbr data-start=\"985\" data-end=\"988\"\u003e• \u003cstrong data-start=\"990\" data-end=\"1019\"\u003eGenuine OEM Compatibility\u003c\/strong\u003e – Designed specifically for Goodman and Amana gas furnaces\u003cbr data-start=\"1078\" data-end=\"1081\"\u003e• \u003cstrong data-start=\"1083\" data-end=\"1123\"\u003eIntegrated Regulator Manifold Design\u003c\/strong\u003e – Maintains precise gas pressure and burner performance\u003cbr data-start=\"1179\" data-end=\"1182\"\u003e• \u003cstrong data-start=\"1184\" data-end=\"1219\"\u003eReliable Furnace Safety Control\u003c\/strong\u003e – Supports safe ignition sequencing and stable furnace operation\u003c\/p\u003e\n\u003chr data-start=\"1288\" data-end=\"1291\"\u003e\n\u003ch2 data-section-id=\"1x3ymsk\" data-start=\"1293\" data-end=\"1335\"\u003eProduct Details and Key Specifications:\u003c\/h2\u003e\n\u003cp data-start=\"1337\" data-end=\"1893\"\u003e• \u003cstrong data-start=\"1339\" data-end=\"1355\"\u003ePart Number:\u003c\/strong\u003e 0151F00000PS\u003cbr data-start=\"1368\" data-end=\"1371\"\u003e• \u003cstrong data-start=\"1373\" data-end=\"1390\"\u003eManufacturer:\u003c\/strong\u003e Goodman \/ Amana (Genuine OEM)\u003cbr data-start=\"1420\" data-end=\"1423\"\u003e• \u003cstrong data-start=\"1425\" data-end=\"1439\"\u003ePart Type:\u003c\/strong\u003e 2-Stage Gas Valve with Regulator Manifold\u003cbr data-start=\"1481\" data-end=\"1484\"\u003e• \u003cstrong data-start=\"1486\" data-end=\"1502\"\u003eApplication:\u003c\/strong\u003e Residential Gas Furnace Systems\u003cbr data-start=\"1534\" data-end=\"1537\"\u003e• \u003cstrong data-start=\"1539\" data-end=\"1550\"\u003eStages:\u003c\/strong\u003e Two-Stage Heating Operation\u003cbr data-start=\"1578\" data-end=\"1581\"\u003e• \u003cstrong data-start=\"1583\" data-end=\"1596\"\u003eFunction:\u003c\/strong\u003e Gas Flow Regulation \u0026amp; Burner Control\u003cbr data-start=\"1633\" data-end=\"1636\"\u003e• \u003cstrong data-start=\"1638\" data-end=\"1652\"\u003eFuel Type:\u003c\/strong\u003e Natural Gas \/ LP Convertible (application dependent)\u003cbr data-start=\"1705\" data-end=\"1708\"\u003e• \u003cstrong data-start=\"1710\" data-end=\"1728\"\u003eConfiguration:\u003c\/strong\u003e Integrated Regulator Manifold\u003cbr data-start=\"1758\" data-end=\"1761\"\u003e• \u003cstrong data-start=\"1763\" data-end=\"1785\"\u003eCompatible Brands:\u003c\/strong\u003e Goodman, Amana\u003cbr data-start=\"1800\" data-end=\"1803\"\u003e• \u003cstrong data-start=\"1805\" data-end=\"1827\"\u003eInstallation Type:\u003c\/strong\u003e Direct OEM Replacement\u003cbr data-start=\"1850\" data-end=\"1853\"\u003e• \u003cstrong data-start=\"1855\" data-end=\"1875\"\u003eShipping Weight:\u003c\/strong\u003e Approx. 2-4 lbs\u003c\/p\u003e\n\u003chr data-start=\"1895\" data-end=\"1898\"\u003e\n\u003ch2 data-section-id=\"7iws84\" data-start=\"1900\" data-end=\"1965\"\u003e🛠️ HVAC Depot Pro Tip: Verify Gas Pressure After Installation\u003c\/h2\u003e\n\u003cp data-start=\"1967\" data-end=\"2282\"\u003eAfter replacing a gas valve, always verify inlet and manifold gas pressures using a calibrated manometer. Improper gas pressure can cause ignition failures, delayed ignition, poor combustion, or excessive heat exchanger stress. Always confirm proper LP conversion settings if applicable to the furnace installation.\u003c\/p\u003e\n\u003chr data-start=\"2284\" data-end=\"2287\"\u003e\n\u003ch2 data-section-id=\"1rctmzz\" data-start=\"2289\" data-end=\"2324\"\u003eCross-Reference \u0026amp; Compatibility:\u003c\/h2\u003e\n\u003cp data-start=\"2326\" data-end=\"2416\"\u003eThe Goodman-Amana 0151F00000PS is a direct OEM replacement for the following applications:\u003c\/p\u003e\n\u003cp data-start=\"2418\" data-end=\"2613\"\u003e• \u003cstrong data-start=\"2420\" data-end=\"2436\"\u003eOEM Numbers:\u003c\/strong\u003e 0151F00000PS\u003cbr data-start=\"2449\" data-end=\"2452\"\u003e• \u003cstrong data-start=\"2454\" data-end=\"2476\"\u003eCompatible Brands:\u003c\/strong\u003e Goodman, Amana\u003cbr data-start=\"2491\" data-end=\"2494\"\u003e• \u003cstrong data-start=\"2496\" data-end=\"2517\"\u003eApplication Type:\u003c\/strong\u003e Residential Furnace Gas Valves\u003cbr data-start=\"2548\" data-end=\"2551\"\u003e• \u003cstrong data-start=\"2553\" data-end=\"2569\"\u003eValve Style:\u003c\/strong\u003e 2-Stage Gas Valve with Regulator Manifold\u003c\/p\u003e\n\u003chr data-start=\"2615\" data-end=\"2618\"\u003e\n\u003ch2 data-section-id=\"9l9x9z\" data-start=\"2620\" data-end=\"2658\"\u003eExtensive Model Compatibility List:\u003c\/h2\u003e\n\u003ch3 data-section-id=\"79lh2d\" data-start=\"2660\" data-end=\"2706\"\u003eCompatible Goodman \/ Amana Furnace Series:\u003c\/h3\u003e\n\u003cp data-start=\"2708\" data-end=\"2980\"\u003e• GMVC Series Furnaces\u003cbr data-start=\"2730\" data-end=\"2733\"\u003e• AMVC Series Furnaces\u003cbr data-start=\"2755\" data-end=\"2758\"\u003e• GMEC Series Furnaces\u003cbr data-start=\"2780\" data-end=\"2783\"\u003e• High-Efficiency Two-Stage Gas Furnaces\u003cbr data-start=\"2823\" data-end=\"2826\"\u003e• Variable-Speed Furnace Systems\u003cbr data-start=\"2858\" data-end=\"2861\"\u003e• Residential Gas Heating Systems\u003cbr data-start=\"2894\" data-end=\"2897\"\u003e• Select Goodman Residential Furnaces\u003cbr data-start=\"2934\" data-end=\"2937\"\u003e• Select Amana Residential Furnace Models\u003c\/p\u003e\n\u003cp data-start=\"2982\" data-end=\"3098\"\u003e\u003cem data-start=\"2982\" data-end=\"3098\"\u003eAlways verify gas type, staging configuration, manifold orientation, and electrical compatibility before ordering.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":53295309095275,"sku":"193031117516","price":214.83,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/0151F00000PS.jpg?v=1779828608","url":"https:\/\/tophvacparts.com\/products\/goodman-amana-0151f00000ps-gas-valve-genuine-oem-2-stage-regulator-manifold-gas-valve","provider":"HVAC Parts and Equipment Depot: Homeowners \u0026 Contractors Welcome | Plano, TX","version":"1.0","type":"link"}