{"product_id":"goodman-amana-0131f00006s-induced-draft-motor-genuine-oem-115v-furnace-draft-inducer-motor","title":"Goodman-Amana 0131F00006S Induced Draft Motor – Genuine OEM 115V Furnace Draft Inducer Motor","description":"\u003cp data-start=\"98\" data-end=\"542\"\u003eThe Goodman-Amana 0131F00006S Induced Draft Motor is a genuine OEM furnace draft inducer motor engineered to provide reliable combustion airflow and safe venting performance in residential and light commercial gas furnace systems. Designed for 115-volt operation with heavy-duty Class B insulation, this inducer motor plays a critical role in removing combustion gases from the heat exchanger and maintaining proper furnace ignition conditions.\u003c\/p\u003e\n\u003cp data-start=\"544\" data-end=\"894\"\u003eManufactured to exact OEM specifications, the 0131F00006S induced draft motor delivers dependable airflow performance, stable operation, and reliable pressure switch activation during the furnace heating cycle. Its durable construction and precision-balanced motor design help minimize vibration while supporting long-lasting HVAC system reliability.\u003c\/p\u003e\n\u003chr data-start=\"896\" data-end=\"899\"\u003e\n\u003ch2 data-section-id=\"1ybcqkm\" data-start=\"901\" data-end=\"930\"\u003eKey Features and Function:\u003c\/h2\u003e\n\u003cp data-start=\"932\" data-end=\"1323\"\u003e• \u003cstrong data-start=\"934\" data-end=\"964\"\u003eCombustion Airflow Control\u003c\/strong\u003e – Maintains proper venting and furnace draft performance\u003cbr data-start=\"1021\" data-end=\"1024\"\u003e• \u003cstrong data-start=\"1026\" data-end=\"1055\"\u003eGenuine OEM Compatibility\u003c\/strong\u003e – Designed specifically for Goodman and Amana furnace systems\u003cbr data-start=\"1117\" data-end=\"1120\"\u003e• \u003cstrong data-start=\"1122\" data-end=\"1159\"\u003eReliable Furnace Safety Operation\u003c\/strong\u003e – Supports pressure switch activation and safe ignition sequencing\u003cbr data-start=\"1226\" data-end=\"1229\"\u003e• \u003cstrong data-start=\"1231\" data-end=\"1264\"\u003eHeavy-Duty Motor Construction\u003c\/strong\u003e – Class B insulation provides dependable HVAC durability\u003c\/p\u003e\n\u003chr data-start=\"1325\" data-end=\"1328\"\u003e\n\u003ch2 data-section-id=\"1x3ymsk\" data-start=\"1330\" data-end=\"1372\"\u003eProduct Details and Key Specifications:\u003c\/h2\u003e\n\u003cp data-start=\"1374\" data-end=\"1843\"\u003e• \u003cstrong data-start=\"1376\" data-end=\"1392\"\u003ePart Number:\u003c\/strong\u003e 0131F00006S\u003cbr data-start=\"1404\" data-end=\"1407\"\u003e• \u003cstrong data-start=\"1409\" data-end=\"1426\"\u003eManufacturer:\u003c\/strong\u003e Goodman \/ Amana (Genuine OEM)\u003cbr data-start=\"1456\" data-end=\"1459\"\u003e• \u003cstrong data-start=\"1461\" data-end=\"1475\"\u003ePart Type:\u003c\/strong\u003e Induced Draft Motor\u003cbr data-start=\"1495\" data-end=\"1498\"\u003e• \u003cstrong data-start=\"1500\" data-end=\"1512\"\u003eVoltage:\u003c\/strong\u003e 115V\u003cbr data-start=\"1517\" data-end=\"1520\"\u003e• \u003cstrong data-start=\"1522\" data-end=\"1532\"\u003ePhase:\u003c\/strong\u003e 3 Phase (3PH)\u003cbr data-start=\"1546\" data-end=\"1549\"\u003e• \u003cstrong data-start=\"1551\" data-end=\"1565\"\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003cbr data-start=\"1571\" data-end=\"1574\"\u003e• \u003cstrong data-start=\"1576\" data-end=\"1603\"\u003eMotor Insulation Class:\u003c\/strong\u003e Class B\u003cbr data-start=\"1611\" data-end=\"1614\"\u003e• \u003cstrong data-start=\"1616\" data-end=\"1629\"\u003eAmperage:\u003c\/strong\u003e 1.4 A\u003cbr data-start=\"1635\" data-end=\"1638\"\u003e• \u003cstrong data-start=\"1640\" data-end=\"1656\"\u003eApplication:\u003c\/strong\u003e Gas Furnace Draft Inducer System\u003cbr data-start=\"1689\" data-end=\"1692\"\u003e• \u003cstrong data-start=\"1694\" data-end=\"1707\"\u003eFunction:\u003c\/strong\u003e Removes Combustion Gases \u0026amp; Maintains Draft Airflow\u003cbr data-start=\"1758\" data-end=\"1761\"\u003e• \u003cstrong data-start=\"1763\" data-end=\"1785\"\u003eCompatible Brands:\u003c\/strong\u003e Goodman, Amana\u003cbr data-start=\"1800\" data-end=\"1803\"\u003e• \u003cstrong data-start=\"1805\" data-end=\"1825\"\u003eShipping Weight:\u003c\/strong\u003e Approx. 4-8 lbs\u003c\/p\u003e\n\u003chr data-start=\"1845\" data-end=\"1848\"\u003e\n\u003ch2 data-section-id=\"t8xev3\" data-start=\"1850\" data-end=\"1925\"\u003e🛠️ HVAC Depot Pro Tip: Check Vent Restrictions Before Motor Replacement\u003c\/h2\u003e\n\u003cp data-start=\"1927\" data-end=\"2249\"\u003eBefore replacing an induced draft motor, inspect the vent pipe, condensate drain, and pressure switch tubing for restrictions or moisture buildup. Many furnace lockout issues are caused by blocked venting or clogged pressure ports rather than a failed inducer motor itself. Always verify proper airflow after installation.\u003c\/p\u003e\n\u003chr data-start=\"2251\" data-end=\"2254\"\u003e\n\u003ch2 data-section-id=\"1rctmzz\" data-start=\"2256\" data-end=\"2291\"\u003eCross-Reference \u0026amp; Compatibility:\u003c\/h2\u003e\n\u003cp data-start=\"2293\" data-end=\"2382\"\u003eThe Goodman-Amana 0131F00006S is a direct OEM replacement for the following applications:\u003c\/p\u003e\n\u003cp data-start=\"2384\" data-end=\"2562\"\u003e• \u003cstrong data-start=\"2386\" data-end=\"2402\"\u003eOEM Numbers:\u003c\/strong\u003e 0131F00006S\u003cbr data-start=\"2414\" data-end=\"2417\"\u003e• \u003cstrong data-start=\"2419\" data-end=\"2441\"\u003eCompatible Brands:\u003c\/strong\u003e Goodman, Amana\u003cbr data-start=\"2456\" data-end=\"2459\"\u003e• \u003cstrong data-start=\"2461\" data-end=\"2482\"\u003eApplication Type:\u003c\/strong\u003e Furnace Induced Draft Motors\u003cbr data-start=\"2511\" data-end=\"2514\"\u003e• \u003cstrong data-start=\"2516\" data-end=\"2532\"\u003eMotor Style:\u003c\/strong\u003e Furnace Draft Inducer Motor\u003c\/p\u003e\n\u003chr data-start=\"2564\" data-end=\"2567\"\u003e\n\u003ch2 data-section-id=\"9l9x9z\" data-start=\"2569\" data-end=\"2607\"\u003eExtensive Model Compatibility List:\u003c\/h2\u003e\n\u003ch3 data-section-id=\"79lh2d\" data-start=\"2609\" data-end=\"2655\"\u003eCompatible Goodman \/ Amana Furnace Series:\u003c\/h3\u003e\n\u003cp data-start=\"2657\" data-end=\"2954\"\u003e• GMEC Series Furnaces\u003cbr data-start=\"2679\" data-end=\"2682\"\u003e• GMES Series Furnaces\u003cbr data-start=\"2704\" data-end=\"2707\"\u003e• GMS8 Series Furnaces\u003cbr data-start=\"2729\" data-end=\"2732\"\u003e• GDS8 Series Furnaces\u003cbr data-start=\"2754\" data-end=\"2757\"\u003e• GDH8 Series Furnaces\u003cbr data-start=\"2779\" data-end=\"2782\"\u003e• Select Goodman High-Efficiency Furnaces\u003cbr data-start=\"2823\" data-end=\"2826\"\u003e• Select Amana Residential Gas Furnaces\u003cbr data-start=\"2865\" data-end=\"2868\"\u003e• Select Induced Draft Furnace Systems\u003cbr data-start=\"2906\" data-end=\"2909\"\u003e• Select Upflow \u0026amp; Horizontal Furnace Models\u003c\/p\u003e\n\u003cp data-start=\"2956\" data-end=\"3069\"\u003e\u003cem data-start=\"2956\" data-end=\"3069\"\u003eAlways verify voltage, mounting configuration, vent orientation, and electrical specifications before ordering.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":53248974422379,"sku":"193031169997","price":280.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/0131F00006S_60dc26b1-e96f-4139-98db-45bed64771ab.jpg?v=1779134497","url":"https:\/\/tophvacparts.com\/products\/goodman-amana-0131f00006s-induced-draft-motor-genuine-oem-115v-furnace-draft-inducer-motor","provider":"HVAC Parts and Equipment Depot: Homeowners \u0026 Contractors Welcome | Plano, TX","version":"1.0","type":"link"}