{"product_id":"genteq-3905-carrier-condenser-fan-motor-hc39ge237-1-4-hp-1100-rpm-208-230v-ccw","title":"Genteq 3905 Carrier Condenser Fan Motor HC39GE237– 1\/4 HP, 1100 RPM, 208-230V, CCW","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eGenteq 3905 Carrier Condenser Fan Motor – 1\/4 HP, 1100 RPM, 208-230V, CCW\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eGenteq 3905 Carrier Condenser Fan Motor\u003c\/strong\u003e, also identified as \u003cstrong\u003e5KCP39EGS070S\u003c\/strong\u003e, is a replacement condenser fan motor designed for compatible \u003cstrong\u003eCarrier-family HVAC equipment\u003c\/strong\u003e. This motor is rated at \u003cstrong\u003e1\/4 HP, 1100 RPM, 208-230V, and 1.4 amps\u003c\/strong\u003e, with a single-speed, single-phase configuration.\u003c\/p\u003e\n\u003cp\u003eThe 3905 features \u003cstrong\u003eCCW rotation when viewed from the shaft end\u003c\/strong\u003e, a \u003cstrong\u003e48 NEMA frame\u003c\/strong\u003e, sleeve bearings, and a \u003cstrong\u003e2-inch x 1\/2-inch shaft\u003c\/strong\u003e. It requires a \u003cstrong\u003e5 MFD \/ 370 VAC run capacitor\u003c\/strong\u003e, which is \u003cstrong\u003enot included\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Features \u0026amp; Function\u003c\/h2\u003e\n\u003cp\u003e• \u003cstrong\u003e1\/4 HP\u003c\/strong\u003e – Replacement condenser fan motor for compatible HVAC equipment\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003e1100 RPM\u003c\/strong\u003e – Designed to match compatible condenser fan applications\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003e208-230 Volts\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003e1.4 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003e60 Hz\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eSingle Phase\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003e1-Speed Operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eCCW Shaft-End Rotation\u003c\/strong\u003e – Counterclockwise when viewed from the shaft end\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003e48 NEMA Frame\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eClass B Insulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eSleeve Bearings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eVSD Mounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eBand Base\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eContinuous Air Over\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eAutomatic Overload Protector\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003e2\" Long x 1\/2\" Diameter Shaft\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003e5 MFD \/ 370 VAC Run Capacitor Required\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eCapacitor Not Included\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eProduct Details \u0026amp; Key Specifications\u003c\/h2\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGenteq\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3905\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5KCP39EGS070S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCondenser Fan Motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHorsepower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRPM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpeeds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRotation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCCW Shaft End\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNEMA Frame\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBearing Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSleeve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShaft Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShaft Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic Protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Cooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContinuous Air Over\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequired Capacitor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 MFD \/ 370 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitor Included\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB Dimension\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.50\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC Dimension\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.95\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch2\u003e🛠️ HVAC Depot Pro Tip: Pay Attention to the HP Cross-References\u003c\/h2\u003e\n\u003cp\u003eWhen replacing a condenser fan motor with the \u003cstrong\u003eGenteq 3905\u003c\/strong\u003e, verify more than the cross-reference number. Match the \u003cstrong\u003evoltage, RPM, rotation, shaft dimensions, mounting configuration, amperage, horsepower, and capacitor requirement\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eImportant Horsepower Note\u003c\/h3\u003e\n\u003cp\u003eSome cross-referenced OEM motors were originally rated at \u003cstrong\u003e1\/5 HP\u003c\/strong\u003e, while the \u003cstrong\u003eGenteq 3905 is rated at 1\/4 HP\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis is especially important when replacing motors associated with \u003cstrong\u003e1086598, K55HXHDD-8562, HC37GZ003B, and 5KCP39BGZ256S\u003c\/strong\u003e. Verify the equipment and original motor specifications before installation rather than assuming interchangeability based only on a cross-reference.\u003c\/p\u003e\n\u003cp\u003eThe 3905 requires a \u003cstrong\u003e5 MFD \/ 370 VAC run capacitor\u003c\/strong\u003e. The capacitor is \u003cstrong\u003enot included\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCross-Reference \u0026amp; Replacement Numbers\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGenteq 3905 \/ 5KCP39EGS070S\u003c\/strong\u003e cross-references with:\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eGE 3905\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003e5KCP39EGY823S\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003e5KCP39EGS070S\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eHC39GE237\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003e1086598\u003c\/strong\u003e*\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eK55HXHDD-8562\u003c\/strong\u003e*\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eHC37GZ003B\u003c\/strong\u003e*\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003e5KCP39BGZ256S\u003c\/strong\u003e*\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e*Important:\u003c\/strong\u003e These OEM cross-reference applications may have originally used a \u003cstrong\u003e1\/5 HP motor\u003c\/strong\u003e. Verify the original motor and equipment requirements before replacement.\u003c\/p\u003e","brand":"Genteq","offers":[{"title":"Default Title","offer_id":53800118911339,"sku":"5KCP39EGY823S","price":265.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/3904.jpg?v=1788544337","url":"https:\/\/tophvacparts.com\/products\/genteq-3905-carrier-condenser-fan-motor-hc39ge237-1-4-hp-1100-rpm-208-230v-ccw","provider":"HVAC Parts and Equipment Depot Open To Homeowners and Contractors","version":"1.0","type":"link"}