{"product_id":"firstchoice-19l32-condenser-fan-motor-1-2-hp-1075-rpm-460v-1ph-70c-high-ambient","title":"FirstChoice 19L32 Condenser Fan Motor - 1\/2 HP 1075 RPM 460V 1PH 70C High Ambient","description":"\u003ch1\u003eFirstChoice 19L32 Condenser Fan Motor - 1\/2 HP 1075 RPM 460V 1PH 70C High Ambient\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003e19L32\u003c\/strong\u003e is a heavy-duty \u003cstrong\u003eFirstChoice\u003c\/strong\u003e replacement motor engineered to function as the primary heat-rejection driver in high-voltage commercial condensing units. Functioning as the \"heart\" of the airflow system, this motor is specifically designed for \u003cstrong\u003e460V single-phase\u003c\/strong\u003e applications where standard residential voltages are insufficient. This motor is built to withstand extreme rooftop environments, featuring a \u003cstrong\u003e70C (158°F)\u003c\/strong\u003e high-ambient rating that prevents thermal tripping during record-breaking summer temperatures. By maintaining precise \u003cstrong\u003e1075 RPM\u003c\/strong\u003e cycles, it ensures the refrigerant in your commercial split system or rooftop unit is properly subcooled for maximum efficiency.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Voltage Industrial Build:\u003c\/strong\u003e Specifically rated for \u003cstrong\u003e460V\u003c\/strong\u003e operation, ensuring compatibility with commercial power grids without the need for step-down transformers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Ambient Thermal Rating:\u003c\/strong\u003e The \u003cstrong\u003e70C\u003c\/strong\u003e rating allows this motor to operate in the hottest \"attic-style\" or enclosed rooftop conditions where standard motors fail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Reliability:\u003c\/strong\u003e As a FirstChoice part, the \u003cstrong\u003e19L32\u003c\/strong\u003e offers a precise mechanical fit for Lennox and Allied commercial platforms, maintaining factory airflow curves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance-Free Bearings:\u003c\/strong\u003e Features permanently lubricated ball bearings designed to handle the vertical-shaft-down loads common in outdoor condenser fans.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Safety Circuitry:\u003c\/strong\u003e Integrated internal overload protection monitors winding temperature to prevent catastrophic motor failure during a fan blade blockage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Details\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e FirstChoice\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Allied Air \/ Lennox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory Number:\u003c\/strong\u003e 19L32\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 16.8 lbs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHorsepower:\u003c\/strong\u003e 1\/2 HP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 460V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e 1 Phase (Single Phase)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRPM:\u003c\/strong\u003e 1075\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient Temperature:\u003c\/strong\u003e 70C (High Ambient)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Totally Enclosed Air Over (TEAO)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e🛠️ HVAC Depot Pro Tip\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\"Check the Rotation and Leads\"\u003c\/strong\u003e—When installing the \u003cstrong\u003e19L32\u003c\/strong\u003e, verify the rotation direction before final assembly. Commercial 460V systems often use higher-gauge wiring; ensure all lead wires are secured away from the fan blade's path using UV-rated zip ties. Because this is a high-voltage component, always verify the \u003cstrong\u003egrounding wire\u003c\/strong\u003e is securely bonded to the motor bracket to prevent stray voltage from damaging the unit’s control board or sensitive electronic expansion valves.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCross-Reference\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect Replacement:\u003c\/strong\u003e 19L3201\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuperseded Numbers:\u003c\/strong\u003e 78M74, 78M7401\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrawing Numbers:\u003c\/strong\u003e MOT19L32\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhite-Rodgers\/Emerson Equivalent:\u003c\/strong\u003e Emerson 1872, Genteq 3872\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eModel Compatibility\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLennox T-Class\u003c\/strong\u003e (Suffixes: 090, 102, 120, 150)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLennox Landmark\u003c\/strong\u003e (Suffixes: LGC090, LGC102, LGC120, LGC150)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAllied Commercial\u003c\/strong\u003e (Suffixes: KGA090, KGA102, KGA120, KGA150)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Lennox","offers":[{"title":"Default Title","offer_id":52233017131371,"sku":"FC-19L32-460V-70C","price":192.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/19L32.jpg?v=1772131680","url":"https:\/\/tophvacparts.com\/products\/firstchoice-19l32-condenser-fan-motor-1-2-hp-1075-rpm-460v-1ph-70c-high-ambient","provider":"HVAC Parts and Equipment Depot","version":"1.0","type":"link"}