{"product_id":"factory-authorized-parts™-ceso110057-02-furnace-control-board-integrated-hsi-control-single-stage-oem-logic-module","title":"Factory Authorized Parts™ CESO110057-02 Furnace Control Board | Integrated HSI Control | Single-Stage OEM Logic Module","description":"\u003ch1\u003eFactory Authorized Parts™ CESO110057-02,\u003cb\u003eCESO110057-01, CESO110057, CESO110048, CESO110020, HH84AA016\u003c\/b\u003e Furnace Control Board | Integrated HSI Control | Single-Stage OEM Logic Module\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eFactory Authorized Parts™ CESO110057-02\u003c\/strong\u003e serves as the central \"brain\" of your heating system, meticulously managing every phase of the furnace operation. This \u003cstrong\u003eOEM-focused\u003c\/strong\u003e integrated furnace control (IFC) is the specific hardware responsible for orchestrating the ignition sequence—from the initial inducer draft and Hot Surface Ignitor (HSI) warm-up to the final blower fan-off delay. Specifically engineered for \u003cstrong\u003eCarrier, Bryant, and Payne single-stage furnace series\u003c\/strong\u003e, this board ensures the \"body\" of the furnace communicates perfectly with the thermostat. By replacing a malfunctioning or \"blind\" board with the CESO110057-02, you restore the system's ability to monitor safety limits and flame rectification, preventing dangerous gas buildup and ensuring peak heating efficiency.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenuine OEM Logic Control:\u003c\/strong\u003e Specifically engineered to replace part number \u003cstrong\u003eCESO110057-02\u003c\/strong\u003e, maintaining factory-spec timing for the inducer, ignitor, and blower motor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Safety Monitoring:\u003c\/strong\u003e Continuously scans the high-limit switches, rollout sensors, and pressure switches to ensure the system shuts down instantly if a fault is detected.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMicroprocessor Troubleshooting:\u003c\/strong\u003e Features an onboard diagnostic LED that flashes specific fault codes, allowing for rapid and accurate system troubleshooting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay \u0026amp; Noise Resolution:\u003c\/strong\u003e Includes heavy-duty onboard relays designed to fix issues with \"clicking\" controls or blowers that fail to engage after the heat cycle starts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlug-and-Play Compatibility:\u003c\/strong\u003e Designed with exact-match multi-pin molex connectors and spade terminals to ensure a secure, error-free connection to the factory wiring harness.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Details\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Factory Authorized Parts™ (Carrier\/Bryant\/Payne)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Carrier Global Corporation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart #:\u003c\/strong\u003e CESO110057-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.75 lbs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 VAC (Control) \/ 120 VAC (Line)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnition Type:\u003c\/strong\u003e Hot Surface Ignition (HSI)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower Speeds:\u003c\/strong\u003e Supports Multi-Speed PSC Blower Motors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Protection:\u003c\/strong\u003e 3A Automotive-style plug-in fuse\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e🛠️ HVAC Depot Pro Tip\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eTake a Picture First:\u003c\/strong\u003e Before disconnecting any wires from the old board, photograph the entire layout—specifically the individual wires on the \"Park,\" \"Heat,\" and \"Cool\" terminals. These are easily mixed up during the swap. Conduct a \u003cstrong\u003ediagnostic check\u003c\/strong\u003e by verifying the 3A fuse on the new board is seated firmly; if the furnace has a low-voltage short in the thermostat wiring, this fuse will pop instantly to protect the new CESO110057-02 from permanent damage. Always handle the board by the edges to avoid static discharge to the sensitive microchips.\u003c\/p\u003e\n\u003ch2\u003eCross-Reference\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuperseded \/ Legacy:\u003c\/strong\u003e CESO110057-00, CESO110057-01, HK42FZ004\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrawing \/ OEM Equivalents:\u003c\/strong\u003e 1012-920, 1012-83-9201, PCBBF112S\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhite-Rodgers\/Emerson Equivalents:\u003c\/strong\u003e 50A55-843 (Universal equivalent)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand Equivalents:\u003c\/strong\u003e Carrier, Bryant, Payne, Day \u0026amp; Night, Totaline\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eModel Compatibility\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarrier 58 Series\u003c\/strong\u003e (Suffixes: 58STA, 58STX, 58WAV, 58PAV, 58MXA, 58MXB)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBryant 300 Series\u003c\/strong\u003e (Suffixes: 310AAV, 310JAV, 311AAV, 311JAV, 340MAV, 350MAV)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePayne PG8\/PG9 Series\u003c\/strong\u003e (Suffixes: PG8MAA, PG8JAA, PG9MAA, PG9MAB)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Units\u003c\/strong\u003e (Suffixes: 395CAV, 373LAV, 376CAV)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Carrier","offers":[{"title":"Default Title","offer_id":52238161215851,"sku":"781897136231","price":825.54,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/LH33WP002.jpg?v=1770145352","url":"https:\/\/tophvacparts.com\/products\/factory-authorized-parts%e2%84%a2-ceso110057-02-furnace-control-board-integrated-hsi-control-single-stage-oem-logic-module","provider":"HVAC Parts and Equipment Depot Open To Homeowners and Contractors","version":"1.0","type":"link"}