{"product_id":"century-condenser-motor-2-hp-3-phase-460-208-230v-1140-1200-rpm","title":"Century Condenser Motor | 2 HP | 3 Phase | 460\/208-230V | 1140\/1200 RPM","description":"\u003ch1\u003e\u003cstrong\u003eCentury H699 Condenser Fan Motor | 2.0 HP | 3 Phase | 460\/208-230V | 1140\/1200 RPM | P56Y Frame | ODP \u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe Century \u003cstrong\u003eH699 \u003c\/strong\u003eis a \u003cstrong\u003ehigh\u003c\/strong\u003e-\u003cstrong\u003ecapacity \u003c\/strong\u003e\"powerhouse\" designed for demanding \u003cstrong\u003ecommercial outdoor condenser applications\u003c\/strong\u003e, typically found in 15-ton and larger cooling systems. Operating as the \"muscle\" for heat rejection, this \u003cstrong\u003eOEM\u003c\/strong\u003e-focused motor drives massive fan blades to dissipate heat from the condensing coils, ensuring the refrigeration cycle remains stable under heavy loads. Its \u003cstrong\u003ethree\u003c\/strong\u003e-\u003cstrong\u003ephase design \u003c\/strong\u003eacts as a robust partner to the system's \"brain,\" providing efficient, high-torque performance that is critical for large-scale commercial furnace and AC series from brands like Carrier, Trane, and York. \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy-Duty OEM Replacement:\u003c\/strong\u003e Specifically engineered as a direct replacement for part number H699, meeting the rigorous performance standards of major commercial HVAC manufacturers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-Voltage Versatility: \u003c\/strong\u003eSupports both 208-230V and 460V three-phase power supplies, allowing for seamless integration into diverse commercial electrical infrastructures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e70°C Ambient Rating:\u003c\/strong\u003e Features advanced insulation and an Open Drip-Proof (ODP) design to fix overheating issues in extreme rooftop environments where standard motors fail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVFD-Ready Insulation:\u003c\/strong\u003e Equipped with the patented MAXGuard® insulation system, which monitors and protects the motor against the electrical stress of variable frequency drives.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet \u0026amp; Reliable Operation:\u003c\/strong\u003e Built with permanently lubricated, double-sealed ball bearings to fix mechanical grinding and ensure whisper-quiet operation during continuous duty. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Details\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand: \u003c\/strong\u003eCentury (Regal Rexnord)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e H699\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e 34 LB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 208-230\/460V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHorsepower:\u003c\/strong\u003e 2.0 HP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmps:\u003c\/strong\u003e 3.1 \/ 6.8-6.2 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRPM:\u003c\/strong\u003e 1140 \/ 1200 RPM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrame:\u003c\/strong\u003e P56Y (6-1\/2\" Body Diameter)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure: \u003c\/strong\u003eOpen Drip-Proof (ODP) \/ Open Air-Over\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShaft: \u003c\/strong\u003e5\/8\" Diameter x 6-3\/16\" Length (Keyed)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRotation: \u003c\/strong\u003eElectrically Reversible (CW\/CCW)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC: \u003c\/strong\u003e786674024091 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e🛠️ HVAC Depot Pro Tip\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eTake a Picture First: Before removing the original leads from the contactor, photograph the wiring configuration to ensure the three-phase rotation (A-B-C) is maintained. If the fan spins backward after installing the H699, simply swap any two of the three power leads to reverse the direction. Diagnostic Check: Always verify the voltage at the unit matches the motor's lead configuration (Low Voltage vs. High Voltage) before energizing, as improper wiring on a three-phase motor can lead to immediate internal damage. \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCross-Reference\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eSuperseded \/ Legacy: \u003c\/strong\u003e\u003c\/h3\u003e\nUH699, 17152189\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eDrawing \/ OEM Equivalents: \u003c\/strong\u003e\u003c\/h3\u003e\nGrainger 4MB89, A.O. Smith 193857, Dayton 3VG41\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eWhite-Rodgers\/Emerson: \u003c\/strong\u003e\u003c\/h3\u003e\n1874H, 1875\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eMarathon\/Genteq:\u003c\/strong\u003e\u003c\/h3\u003e\nX088, 3204HS \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eModel Compatibility\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eCarrier\/Bryant Commercial \u003c\/strong\u003e\u003c\/h3\u003e\n(Suffixes: 38AKS007, 38AKS008, 38AKS010)\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eTrane Voyager\/Precedent\u003c\/strong\u003e\u003c\/h3\u003e\n(Suffixes: TCH072, TCH090, TCH120)\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eYork\/Johnson Controls Sunline\u003c\/strong\u003e\u003c\/h3\u003e\n(Suffixes: DH072, DH090, DH120)\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\n\u003cstrong\u003eLennox Strategos\u003c\/strong\u003e (Suffixes: SGA036, SGA060)\u003c\/h3\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Century","offers":[{"title":"Default Title","offer_id":52451492331883,"sku":"H699","price":825.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/original_307fea15-6a16-4f67-b769-8b2864be9841.jpg?v=1760124126","url":"https:\/\/tophvacparts.com\/products\/century-condenser-motor-2-hp-3-phase-460-208-230v-1140-1200-rpm","provider":"HVAC Parts and Equipment Depot Open To Homeowners and Contractors","version":"1.0","type":"link"}