{"product_id":"carrier-factory-authorized-parts-ef33cw204-oem-gas-valve-white-rodgers-36j55-503-24v-2-stage-1-2-npt-natural-gas","title":"Carrier Factory Authorized Parts EF33CW204 OEM Gas Valve – White-Rodgers 36J55-503, 24V, 2-Stage, 1\/2\" NPT, Natural Gas","description":"\u003cp class=\"MsoNormal\"\u003eThe Factory Authorized Parts™ EF33CW204 is a genuine Carrier OEM two-stage furnace gas valve, manufactured by White-Rodgers under model 36J55-503. Designed for compatible Carrier, Bryant, and Payne gas furnaces, this valve provides controlled natural gas flow during low- and high-stage heating operation.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFeaturing 24 VAC operation, 1\/2\" NPT inlet and outlet connections, and slow-opening operation, the EF33CW204 works with compatible direct spark or hot surface ignition systems. It is designed to help maintain proper burner operation and heating performance.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features \u0026amp; Function\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003eGenuine Carrier Factory Authorized Parts™\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003eItem \/ MFR #: EF33CW204\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003eWhite-Rodgers Model: 36J55-503\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003e24 VAC, 50\/60 Hz\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003eTwo-stage gas control\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for natural gas applications\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003e1\/2\" NPT inlet and outlet\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003eSlow-opening operation\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003eCompatible with specified direct spark and hot surface ignition systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003eHigh-stage regulator setting: 3.5\" W.C.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003eLow-stage regulator setting: 1.5\" W.C.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for select Carrier, Bryant, and Payne furnaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Details \u0026amp; Key Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eBrand\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eCarrier \/ Factory Authorized Parts\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eValve Manufacturer\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eWhite-Rodgers\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003ePart Number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eEF33CW204\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eValve Model\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e36J55-503\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eProduct Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eFurnace Gas Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eFuel Application\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eNatural Gas\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eControl Voltage\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e24 VAC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eFrequency\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e50\/60 Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eCurrent\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e0.430 A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHeating Stages\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e2-Stage\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eOpening Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eSlow Opening\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 12;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eInlet Connection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e1\/2\" NPT\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 13;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eOutlet Connection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e1\/2\" NPT\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 14;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHigh-Stage Regulator Setting\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e3.5\" W.C.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 15;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eLow-Stage Regulator Setting\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e1.5\" W.C.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 16;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eMaximum Inlet Pressure\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e1\/2 PSI (14\" W.C.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 17;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eIgnition Application\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eDirect Spark \/ Hot Surface Ignition\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 18; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eApplication\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eGas Furnace Heating Systems\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Segoe UI Emoji',sans-serif; mso-bidi-font-family: 'Segoe UI Emoji';\"\u003e🛠️\u003c\/span\u003e HVAC Depot Pro Tip\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe EF33CW204 is a two-stage gas valve, not a standard single-stage replacement.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBefore ordering, confirm:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eOEM Part Number: EF33CW204\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eWhite-Rodgers Model: 36J55-503\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eVoltage: 24 VAC\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eFuel: Natural Gas\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eConnection Size: 1\/2\" NPT\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eHeating Operation: Two Stage\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eOpening Type: Slow Opening\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eDo not substitute a single-stage valve or a different 36J-series valve based only on appearance.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eProfessional installation required. Gas valve replacement includes gas leak testing, manifold pressure adjustments, ignition verification, and combustion testing according to manufacturer instructions.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment \/ Model Compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Carrier EF33CW204 is listed for select Carrier, Bryant, and Payne gas furnaces, including examples from these equipment families:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eCarrier 58MEC\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eCarrier 58MTB\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eCarrier 58MVB\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eCarrier 58UVB\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eBryant\/Payne 352AAV\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eBryant\/Payne 353BAV\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eBryant\/Payne 355AAV\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eSelect PG9MXA and PG9UAA furnace models\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eExample compatible models include 58MEC080-F-10116, 58MVB060-F-11114, 58UVB080-F-11120, 352AAV036060FBSA, and PG9MXA048080AASA.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eAlways verify the complete furnace model and serial number before ordering.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Carier","offers":[{"title":"Default Title","offer_id":54016409993579,"sku":"822529167985","price":385.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/EF33CW204.jpg?v=1791475793","url":"https:\/\/tophvacparts.com\/products\/carrier-factory-authorized-parts-ef33cw204-oem-gas-valve-white-rodgers-36j55-503-24v-2-stage-1-2-npt-natural-gas","provider":"HVAC Parts and Equipment Depot Open To Homeowners and Contractors","version":"1.0","type":"link"}