{"title":"TXV","description":null,"products":[{"product_id":"trane-american-standard-val12789-thermostatic-expansion-valve-txv-6-ton","title":"Trane \/ American Standard VAL12789 Thermostatic Expansion Valve (TXV) – 6 Ton","description":"\u003ch1 class=\"MsoNormal\"\u003e\u003cb\u003eTrane \/ American Standard VAL12789 Thermostatic Expansion Valve (TXV) – 6 Ton\u003c\/b\u003e\u003c\/h1\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eTrane \/ American Standard VAL12789 Thermostatic Expansion Valve (TXV)\u003c\/b\u003e is an OEM refrigerant metering device designed for compatible \u003cb\u003e6-ton HVAC systems\u003c\/b\u003e. The TXV regulates refrigerant flow entering the evaporator coil according to system demand, helping maintain proper evaporator superheat and efficient cooling performance.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eVAL12789\u003c\/b\u003e is designed to respond to changing operating conditions by adjusting refrigerant flow through the evaporator. A properly operating TXV helps maximize coil performance, maintain system capacity, and protect the compressor from improper refrigerant conditions.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features and Function:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e• \u003cb\u003e6-Ton Capacity\u003c\/b\u003e – Designed for compatible 6-ton HVAC applications\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e• \u003cb\u003eThermostatic Expansion Valve\u003c\/b\u003e – Automatically regulates refrigerant flow into the evaporator coil\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e• \u003cb\u003eSuperheat Control\u003c\/b\u003e – Helps maintain proper evaporator superheat during changing load conditions\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e• \u003cb\u003eOEM Replacement\u003c\/b\u003e – Designed for compatible Trane and American Standard equipment\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e• \u003cb\u003eImproved Refrigerant Control\u003c\/b\u003e – Meters refrigerant according to evaporator demand\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e• \u003cb\u003eCompressor Protection\u003c\/b\u003e – Proper refrigerant metering helps prevent excessive liquid refrigerant from returning to the compressor\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Details and Key Specifications:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e• \u003cb\u003ePart Number:\u003c\/b\u003e VAL12789\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e• \u003cb\u003eManufacturer:\u003c\/b\u003e Trane \/ American Standard\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e• \u003cb\u003ePart Type:\u003c\/b\u003e Thermostatic Expansion Valve\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e• \u003cb\u003eAbbreviation:\u003c\/b\u003e TXV\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e• \u003cb\u003eNominal Capacity:\u003c\/b\u003e 6 Ton\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e• \u003cb\u003eSystem Capacity:\u003c\/b\u003e Approximately 72,000 BTU\/h\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e• \u003cb\u003eApplication:\u003c\/b\u003e Evaporator Coil Refrigerant Metering\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e• \u003cb\u003eFunction:\u003c\/b\u003e Controls refrigerant flow entering the evaporator coil\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e• \u003cb\u003eControl Method:\u003c\/b\u003e Thermostatic \/ Superheat Responsive\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e• \u003cb\u003eInstallation Type:\u003c\/b\u003e OEM Replacement\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e• \u003cb\u003eCompatible Brands:\u003c\/b\u003e Trane, American Standard\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e• \u003cb\u003eEquipment Type:\u003c\/b\u003e Compatible Split Systems, Air Handlers, Evaporator Coils, and HVAC Equipment\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Segoe UI Emoji',sans-serif; mso-bidi-font-family: 'Segoe UI Emoji';\"\u003e🛠️\u003c\/span\u003e HVAC Depot Pro Tip: Verify Refrigerant Type Before Ordering\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eTonnage alone is not enough to select a TXV.\u003c\/b\u003e Before ordering the VAL12789, verify the \u003cb\u003eOEM part number, refrigerant type, valve capacity, inlet\/outlet connection sizes, flow direction, and equipment model number\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eTXVs designed for different refrigerants or applications should not be substituted solely because they have the same nominal tonnage.\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCross-Reference \u0026amp; Compatibility:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eVAL12789\u003c\/b\u003e is intended for compatible HVAC equipment requiring:\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e• \u003cb\u003eOEM Part Number:\u003c\/b\u003e VAL12789\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e• \u003cb\u003eComponent:\u003c\/b\u003e Thermostatic Expansion Valve (TXV)\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e• \u003cb\u003eNominal Capacity:\u003c\/b\u003e 6 Ton\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e• \u003cb\u003eNominal Cooling Capacity:\u003c\/b\u003e 72,000 BTU\/h\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e• \u003cb\u003eApplication:\u003c\/b\u003e Evaporator Refrigerant Metering\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e• \u003cb\u003eCompatible Brands:\u003c\/b\u003e Trane \/ American Standard\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e• \u003cb\u003eCompatible Equipment:\u003c\/b\u003e Select HVAC systems specifically calling for VAL12789\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003ci\u003eAlways verify the complete equipment model number and OEM specifications before ordering. Do not determine TXV compatibility by tonnage alone.\u003c\/i\u003e\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"text-align: center;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\"\u003e\u003c\/div\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eExtensive Equipment Compatibility:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eTypical Applications:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e• Trane Air Conditioning Systems\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e• American Standard Air Conditioning Systems\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e• Trane Heat Pump Systems\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e• American Standard Heat Pump Systems\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e• Evaporator Coils\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e• Air Handlers\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e• Split-System HVAC Equipment\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e• Light Commercial HVAC Equipment\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e• Select 6-Ton Systems Requiring VAL12789\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Trane","offers":[{"title":"Default Title","offer_id":53761770946923,"sku":"VAL12789","price":295.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/Cal12789.jpg?v=1787599902"},{"product_id":"adp-176799993-93-piston-orifice-5-ton-r-22-r-410a-evaporator-coil-refrigerant-metering-device","title":"ADP 176799993 #93 Piston Orifice – 5 Ton, R-22 \/ R-410A Evaporator Coil Refrigerant Metering Device","description":"\u003ch1 dir=\"auto\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eADP 176799993\u003c\/strong\u003e is a \u003cstrong\u003e#93 fixed piston refrigerant metering orifice\u003c\/strong\u003e designed for compatible \u003cstrong\u003eAdvanced Distributor Products (ADP) evaporator coils and air handlers\u003c\/strong\u003e.\u003c\/h1\u003e\n\u003cp dir=\"auto\"\u003eADP's replacement-parts documentation identifies \u003cstrong\u003episton size #93\u003c\/strong\u003e for \u003cstrong\u003e60,000 BTUH \/ 5-ton applications\u003c\/strong\u003e with both \u003cstrong\u003eR-22 and R-410A\u003c\/strong\u003e configurations. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThis precision metering device controls refrigerant flow entering the evaporator coil and is intended to restore the proper fixed-orifice configuration when servicing compatible HVAC equipment.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003eKey Features \u0026amp; Function\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eAdvanced Distributor Products (ADP)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003ePart Number: 176799993\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003ePiston Size: #93 \/ .093\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eFixed refrigerant metering device\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003e5-ton \/ 60,000 BTUH application\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eUsed with compatible \u003cstrong\u003eR-22 systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eUsed with compatible \u003cstrong\u003eR-410A systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eDesigned for compatible ADP evaporator coils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eUsed for refrigerant flow control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eOEM replacement component\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 dir=\"auto\"\u003eProduct Details \u0026amp; Specifications\u003c\/h2\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdvanced Distributor Products (ADP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number \/ MPN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e176799993\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefrigerant Piston \/ Metering Orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePiston Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e#93 \/ .093\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5 Ton\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e60,000 BTUH\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eR-22 Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eR-410A Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMetering Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed Orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvaporator Coil \/ Air Handler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOEM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eADP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp dir=\"auto\"\u003eADP's parts table specifically lists \u003cstrong\u003e176799993\u003c\/strong\u003e as the #93 piston for 60 MBTUH equipment under both its R-22 and R-410A piston tables. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003e🛠️ HVAC Depot Pro Tip\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eDo \u003cstrong\u003enot select a piston by tonnage alone\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eBefore installing the \u003cstrong\u003e176799993 #93 piston\u003c\/strong\u003e, verify:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eOutdoor condenser model\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eEvaporator coil model\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eRefrigerant type\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eRequired piston size\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eManufacturer charging data\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eIndoor\/outdoor equipment combination\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eEven though #93 is associated with 5-ton applications in ADP's parts documentation, the \u003cstrong\u003eoutdoor unit manufacturer's charging or match-up information should determine the required metering device\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003eEquipment \/ Model Compatibility\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eThe \u003cstrong\u003eADP 176799993\u003c\/strong\u003e is intended for compatible ADP evaporator coils and air handlers requiring a \u003cstrong\u003e#93 fixed piston\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eTypical applications include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eADP evaporator coils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eADP air handlers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003e5-ton \/ 60,000 BTUH systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eCompatible R-22 systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eCompatible R-410A systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eFixed-orifice HVAC applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eAlways verify the required piston size for the exact indoor and outdoor equipment combination before installation.\u003c\/p\u003e","brand":"ADP","offers":[{"title":"Default Title","offer_id":53905092575595,"sku":"4502565120","price":25.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/176799993_e2a1c5e0-9bdd-473e-83d3-742a5a9558f2.jpg?v=1790349983"},{"product_id":"adp-176799976-76-piston-orifice-r-410a-4-ton-r-454b-4-ton-r-32-5-ton-hvac-metering-device","title":"ADP 176799976 #76 Piston Orifice – R-410A 4 Ton, R-454B 4 Ton \u0026 R-32 5 Ton HVAC Metering Device","description":"\u003ch1 dir=\"auto\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eADP 176799976\u003c\/strong\u003e is an OEM \u003cstrong\u003e#76 fixed piston refrigerant metering orifice\u003c\/strong\u003e designed for compatible \u003cstrong\u003eAdvanced Distributor Products (ADP) evaporator coils and air handlers\u003c\/strong\u003e.\u003c\/h1\u003e\n\u003cp dir=\"auto\"\u003eThe #76 piston controls refrigerant flow into the evaporator coil and is used in different capacity applications depending on the refrigerant. Current ADP documentation lists \u003cstrong\u003e176799976\u003c\/strong\u003e for \u003cstrong\u003e48,000 BTUH R-410A\u003c\/strong\u003e, \u003cstrong\u003e48,000 BTUH R-454B\u003c\/strong\u003e, and \u003cstrong\u003e60,000 BTUH R-32\u003c\/strong\u003e applications. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003eKey Features \u0026amp; Function\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eAdvanced Distributor Products (ADP)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003ePart Number: 176799976\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003ePiston Size: #76 \/ .076\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eFixed-orifice refrigerant metering device\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eOEM ADP replacement component\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eControls refrigerant flow into the evaporator coil\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eR-410A: 48,000 BTUH \/ 4 Ton\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eR-454B: 48,000 BTUH \/ 4 Ton\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eR-32: 60,000 BTUH \/ 5 Ton\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eDesigned for compatible ADP evaporator coils and air handlers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 dir=\"auto\"\u003eProduct Details \u0026amp; Specifications\u003c\/h2\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eADP – Advanced Distributor Products\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number \/ MPN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e176799976\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefrigerant Piston \/ Metering Orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePiston Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e#76 \/ .076\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMetering Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed Orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eR-410A Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e48,000 BTUH \/ 4 Ton\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eR-454B Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e48,000 BTUH \/ 4 Ton\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eR-32 Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e60,000 BTUH \/ 5 Ton\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvaporator Coil \/ Air Handler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdvanced Distributor Products\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp dir=\"auto\"\u003eCurrent ADP parts documentation confirms the #76 piston and these refrigerant-specific capacity applications. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003e🛠️ HVAC Depot Pro Tip\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eDo not choose a piston by tonnage alone.\u003c\/strong\u003e The same \u003cstrong\u003e#76 piston\u003c\/strong\u003e can be used for different nominal capacities depending on the refrigerant.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eFor example:\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eR-410A → 4 Ton\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eR-454B → 4 Ton\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eR-32 → 5 Ton\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eAlways verify the \u003cstrong\u003eoutdoor condenser model, evaporator coil model, refrigerant, and manufacturer's required piston size\u003c\/strong\u003e before installation.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003eEquipment \/ Model Compatibility\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eThe \u003cstrong\u003eADP 176799976\u003c\/strong\u003e is intended for compatible ADP equipment requiring a \u003cstrong\u003e#76 fixed-orifice piston\u003c\/strong\u003e, including select:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eADP evaporator coils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eADP air handlers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eR-410A systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eR-454B systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eR-32 systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eFixed-orifice HVAC applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eExact compatibility should be determined from the indoor\/outdoor equipment combination rather than tonnage alone.\u003c\/p\u003e","brand":"ADP","offers":[{"title":"Default Title","offer_id":53905107485035,"sku":null,"price":25.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/176799993_2a12ac26-a265-41e7-9c24-8a0f1e0e793e.jpg?v=1790349794"},{"product_id":"adp-100000039-67-florator-piston-orifice-2-5-ton-r-22-3-ton-r-410a-refrigerant-metering-device","title":"ADP 100000039 #67 Florator Piston Orifice – 2.5 Ton R-22 \/ 3 Ton R-410A Refrigerant Metering Device","description":"\u003ch1 dir=\"auto\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eADP 100000039\u003c\/strong\u003e is an OEM \u003cstrong\u003e#67 Florator piston refrigerant metering orifice\u003c\/strong\u003e designed for compatible \u003cstrong\u003eAdvanced Distributor Products (ADP) evaporator coils and air handlers\u003c\/strong\u003e.\u003c\/h1\u003e\n\u003cp dir=\"auto\"\u003eThe #67 fixed piston regulates refrigerant flow into the evaporator coil. ADP specifies this piston for \u003cstrong\u003e30,000 BTUH \/ 2.5-ton R-22 applications\u003c\/strong\u003e and \u003cstrong\u003e36,000 BTUH \/ 3-ton R-410A applications\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003eKey Features \u0026amp; Function\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eAdvanced Distributor Products (ADP)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003ePart Number: 100000039\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003ePiston Size: #67 \/ .067\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eFlorator-style refrigerant piston\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eFixed-orifice metering device\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eR-22: 30,000 BTUH \/ 2.5 Ton\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eR-410A: 36,000 BTUH \/ 3 Ton\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eControls refrigerant flow into the evaporator coil\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eDesigned for compatible ADP coils and air handlers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eOEM ADP replacement component\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 dir=\"auto\"\u003eProduct Details \u0026amp; Specifications\u003c\/h2\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eADP – Advanced Distributor Products\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number \/ MPN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100000039\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlorator Piston \/ Metering Orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePiston Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e#67 \/ .067\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMetering Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed Orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eR-22 Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e30,000 BTUH \/ 2.5 Ton\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eR-410A Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e36,000 BTUH \/ 3 Ton\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvaporator Coil \/ Air Handler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdvanced Distributor Products\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp dir=\"auto\"\u003eADP's parts documentation identifies \u003cstrong\u003e100000039 as piston size #67\u003c\/strong\u003e and confirms the different capacities based on refrigerant type. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003e🛠️ HVAC Depot Pro Tip\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eDo \u003cstrong\u003enot\u003c\/strong\u003e select this piston based on tonnage alone.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe same \u003cstrong\u003e#67 piston\u003c\/strong\u003e has different applications depending on refrigerant:\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eR-22 → 2.5 Ton \/ 30,000 BTUH\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eR-410A → 3 Ton \/ 36,000 BTUH\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eBefore installation, verify the \u003cstrong\u003eoutdoor condenser model, indoor coil model, refrigerant type, and manufacturer's required piston size\u003c\/strong\u003e. ADP specifically warns that an incorrect metering device can result in poor system performance and possible compressor damage. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003eEquipment \/ Model Compatibility\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eThe \u003cstrong\u003eADP 100000039\u003c\/strong\u003e is intended for compatible ADP equipment requiring a \u003cstrong\u003e#67 fixed-orifice piston\u003c\/strong\u003e, including select:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eADP evaporator coils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eADP air handlers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003e2.5-ton R-22 applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003e3-ton R-410A applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\"\u003eFixed-orifice HVAC systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eAlways verify the required piston against the exact indoor and outdoor equipment combination.\u003c\/p\u003e","brand":"ADP","offers":[{"title":"Default Title","offer_id":53905219387755,"sku":"888082194455","price":25.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/176799993.jpg?v=1790349772"},{"product_id":"lennox-25c02-104110-10-oem-txv-thermal-expansion-valve-6-ton-r-410a-refrigerant","title":"Lennox 25C02 \/ 104110-10 OEM TXV Thermal Expansion Valve – 6 Ton, R-410A Refrigerant","description":"\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eSanhua Y8737 \/ RFGF05E-6.0-783\u003c\/b\u003e is a \u003cb\u003ethermal expansion check valve (TXV)\u003c\/b\u003e designed for compatible \u003cb\u003eR-410A air conditioning and heat pump systems ranging from 3.5 to 5 tons\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis refrigerant metering device regulates refrigerant flow into the evaporator coil as system operating conditions change. Proper TXV operation helps maintain the correct refrigerant feed and superheat for efficient evaporator performance.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe valve is identified as \u003cb\u003eSanhua model RFGF05E-6.0-783\u003c\/b\u003e, \u003cb\u003eCat # Y8737\u003c\/b\u003e, with \u003cb\u003e25C02\u003c\/b\u003e used as the newer replacement catalog number.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features \u0026amp; Function\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eBrand: Sanhua\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eCat #: Y8737\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eReplacement Cat #: 25C02\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eModel \/ Part #: RFGF05E-6.0-783\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003eThermal Expansion Valve (TXV)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003eExpansion check valve design\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eR-410A refrigerant\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for \u003cb\u003e3.5 to 5 ton systems\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003e6-ton rated valve body\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003eRefrigerant metering device\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003eRegulates refrigerant entering the evaporator coil\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for compatible air conditioning applications\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for compatible heat pump applications\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003eIndoor evaporator coil application\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Details \u0026amp; Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eBrand\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eSanhua\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCatalog Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eY8737\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eReplacement Catalog Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e25C02\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eModel \/ Part Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eRFGF05E-6.0-783\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eThermal Expansion Check Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCommon Name\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eTXV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eRefrigerant\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eR-410A\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSystem Capacity\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e3.5–5 Ton\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eValve Rating\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e6 Ton\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eApplication\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eIndoor Evaporator Coil\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSystem Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eAir Conditioner \/ Heat Pump\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 12;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eFunction\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eRefrigerant Metering\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 13; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eManufacturer\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eSanhua\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Segoe UI Emoji',sans-serif; mso-bidi-font-family: 'Segoe UI Emoji';\"\u003e🛠️\u003c\/span\u003e HVAC Depot Pro Tip\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eDo not confuse the \u003cb\u003e6-ton valve rating\u003c\/b\u003e with the intended system application.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor the \u003cb\u003eY8737 \/ RFGF05E-6.0-783\u003c\/b\u003e:\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSystem Application: 3.5 to 5 Ton\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eValve Rating: 6 Ton\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eRefrigerant: R-410A\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBefore replacing a TXV, always verify:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eIndoor evaporator coil model\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eOutdoor condenser or heat pump model\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003e\u003cb\u003eR-410A refrigerant\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eSystem capacity\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eRequired TXV\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eValve connections\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eDistributor configuration\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eManufacturer's charging requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eDo not select a TXV by tonnage alone. The correct metering device must match the equipment combination and refrigerant.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment \/ Model Compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eSanhua Y8737 \/ RFGF05E-6.0-783\u003c\/b\u003e is intended for compatible:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003e\u003cb\u003e3.5-ton R-410A systems\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003e\u003cb\u003e4-ton R-410A systems\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003e\u003cb\u003e5-ton R-410A systems\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eCentral air conditioners\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eHeat pump systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eIndoor evaporator coils\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eSelect Lennox-family HVAC equipment requiring this TXV\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eAlways verify compatibility using the complete indoor and outdoor equipment model numbers before ordering.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Lennox","offers":[{"title":"Default Title","offer_id":53972649869675,"sku":"66255161169","price":115.52,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/25C02.jpg?v=1790870486"},{"product_id":"lennox-sanhua-y8735-rfgf05e-2-5-796-expansion-check-valve-txv-1-5-to-2-5-ton-r-410a","title":"Lennox \/ Sanhua Y8735 RFGF05E-2.5-796 Expansion Check Valve TXV – 1.5 to 2.5 Ton, R-410A","description":"\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Description\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eLennox \/ Sanhua Y8735\u003c\/b\u003e, model \u003cb\u003eRFGF05E-2.5-796\u003c\/b\u003e, is a \u003cb\u003ethermal expansion check valve (TXV)\u003c\/b\u003e designed for compatible \u003cb\u003e1.5 to 2.5 ton R-410A air conditioning and heat pump systems\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis TXV serves as the refrigerant metering device, regulating the amount of refrigerant entering the evaporator coil as system load and operating conditions change. Proper refrigerant metering helps maintain the required superheat, evaporator performance, and overall HVAC system efficiency.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features \u0026amp; Function\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eBrand: Lennox \/ Sanhua\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eCat #: Y8735\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eModel \/ Part #: RFGF05E-2.5-796\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eThermal Expansion Valve (TXV)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eExpansion check valve design\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eR-410A refrigerant\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for \u003cb\u003e1.5 to 2.5 ton systems\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eRefrigerant metering device\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eControls refrigerant flow into the evaporator coil\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eHelps maintain proper evaporator superheat\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for compatible air conditioning systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eSuitable for compatible heat pump applications\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eIndoor evaporator coil application\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Details \u0026amp; Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eBrand\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eLennox \/ Sanhua\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCatalog Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eY8735\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eModel \/ Part Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eRFGF05E-2.5-796\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eExpansion Check Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eValve Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eThermal Expansion Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCommon Name\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eTXV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eRefrigerant\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eR-410A\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSystem Capacity\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e1.5–2.5 Ton\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eFunction\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eRefrigerant Metering\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eApplication\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eIndoor Evaporator Coil\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSystem Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eAir Conditioner \/ Heat Pump\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 12; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eManufacturer\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eSanhua\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Segoe UI Emoji',sans-serif; mso-bidi-font-family: 'Segoe UI Emoji';\"\u003e🛠️\u003c\/span\u003e HVAC Depot Pro Tip\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWhen replacing a TXV, \u003cb\u003edo not select the valve based on tonnage alone\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor this valve, verify these primary identifiers:\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCat #: Y8735\u003c\/b\u003e\u003cbr\u003e\u003cb\u003ePart #: RFGF05E-2.5-796\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eSystem Capacity: 1.5–2.5 Ton\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eRefrigerant: R-410A\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBefore installation, also verify:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eIndoor evaporator coil model\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eOutdoor condenser or heat pump model\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eR-410A refrigerant\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eRequired TXV capacity\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eExisting TXV part number\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eInlet and outlet connection sizes\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eEqualizer configuration\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eDistributor configuration\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eManufacturer charging specifications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eUsing the correct TXV is important for maintaining proper refrigerant flow and system superheat.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment \/ Model Compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eLennox \/ Sanhua Y8735 \/ RFGF05E-2.5-796\u003c\/b\u003e is intended for compatible:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003e\u003cb\u003e1.5-ton R-410A systems\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003e\u003cb\u003e2-ton R-410A systems\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003e\u003cb\u003e2.5-ton R-410A systems\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eCentral air conditioning systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eHeat pump systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eIndoor evaporator coils\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eSelect Lennox-family HVAC equipment requiring this TXV\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eAlways verify the complete indoor and outdoor equipment model numbers before ordering.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Lennox","offers":[{"title":"Default Title","offer_id":53972676641131,"sku":"RFGF05E-2.5-796","price":115.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/Y8735.jpg?v=1790870909"},{"product_id":"lennox-56j19-lb-85759f-oem-txv-kit-r-22-heat-pump-1-5-to-3-ton-thermal-expansion-valve","title":"Lennox 56J19 \/ LB-85759F OEM TXV Kit – R-22 Heat Pump, 1.5 to 3 Ton Thermal Expansion Valve","description":"\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSEO Product Title\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eLennox 56J19 \/ LB-85759F OEM TXV Kit – R-22 Heat Pump, 1.5 to 3 Ton Thermal Expansion Valve\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Description\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eLennox 56J19\u003c\/b\u003e, model\/part \u003cb\u003eLB-85759F\u003c\/b\u003e, is an OEM \u003cb\u003ethermal expansion valve (TXV) kit\u003c\/b\u003e designed for compatible \u003cb\u003e1.5 to 3 ton R-22 heat pump systems\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe TXV meters refrigerant entering the evaporator coil according to system operating conditions and load. Proper refrigerant metering helps maintain the correct evaporator superheat, system capacity, and compressor protection in compatible Lennox heat pump applications.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features \u0026amp; Function\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eGenuine \u003cb\u003eLennox OEM\u003c\/b\u003e TXV kit\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eCat #: 56J19\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eModel \/ Part #: LB-85759F\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eThermal Expansion Valve kit\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eR-22 refrigerant\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for \u003cb\u003eheat pump applications\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003e1.5 to 3 ton system range\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eRefrigerant metering device\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eControls refrigerant flow into the evaporator coil\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eHelps maintain proper evaporator superheat\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for compatible Lennox HVAC equipment\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eReplacement\/service kit configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Details \u0026amp; Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eBrand\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eLennox\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCatalog Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e56J19\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eModel \/ Part Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eLB-85759F\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eTXV Kit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eValve Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eThermal Expansion Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCommon Name\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eTXV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eRefrigerant\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eR-22\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSystem Capacity\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e1.5–3 Ton\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eApplication\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eHeat Pump\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eFunction\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eRefrigerant Metering\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eCompatible Lennox HVAC Systems\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 12; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eOEM Component\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Segoe UI Emoji',sans-serif; mso-bidi-font-family: 'Segoe UI Emoji';\"\u003e🛠️\u003c\/span\u003e HVAC Depot Pro Tip\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003ePay close attention to the refrigerant and application when matching this TXV.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor the \u003cb\u003e56J19 \/ LB-85759F\u003c\/b\u003e, the important identifiers are:\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eRefrigerant: R-22\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eApplication: Heat Pump\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eCapacity: 1.5–3 Ton\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eCat #: 56J19\u003c\/b\u003e\u003cbr\u003e\u003cb\u003ePart #: LB-85759F\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eDo not substitute an \u003cb\u003eR-410A TXV\u003c\/b\u003e simply because the tonnage range is the same.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBefore ordering, verify:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list .5in;\"\u003eComplete indoor equipment model\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list .5in;\"\u003eOutdoor heat pump model\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list .5in;\"\u003e\u003cb\u003eR-22 refrigerant\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list .5in;\"\u003e\u003cb\u003e1.5–3 ton capacity range\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list .5in;\"\u003eExisting TXV part number\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list .5in;\"\u003eValve connection sizes\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list .5in;\"\u003eEqualizer configuration\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list .5in;\"\u003eCheck-valve\/bypass requirements\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list .5in;\"\u003eManufacturer charging specifications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment \/ Model Compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eLennox 56J19 \/ LB-85759F\u003c\/b\u003e is intended for select Lennox equipment requiring an \u003cb\u003eR-22 heat pump TXV in the 1.5 to 3 ton range\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eTypical applications include:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003e\u003cb\u003e1.5-ton R-22 heat pumps\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003e\u003cb\u003e2-ton R-22 heat pumps\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003e\u003cb\u003e2.5-ton R-22 heat pumps\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003e\u003cb\u003e3-ton R-22 heat pumps\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eCompatible Lennox evaporator coils\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eCompatible Lennox indoor units\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eR-22 heat pump applications requiring this specific TXV kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eAlways verify the complete equipment model and serial number before ordering.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Lennox","offers":[{"title":"Default Title","offer_id":53972796539243,"sku":"66255117397","price":201.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/56J19.jpg?v=1790873000"},{"product_id":"lennox-10m23-103881-01-oem-3-8-liquid-line-service-valve-smv-series-bar-stock-hvac-valve","title":"Lennox 10M23 \/ 103881-01 OEM 3\/8\" Liquid Line Service Valve – SMV Series Bar-Stock HVAC Valve","description":"\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eLennox 10M23\u003c\/b\u003e, model\/part \u003cb\u003e103881-01\u003c\/b\u003e, is a genuine OEM \u003cb\u003e3\/8-inch liquid line service valve\u003c\/b\u003e designed for select Lennox air conditioners, heat pumps, and outdoor condensing units.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis \u003cb\u003eSMV Series bar-stock service valve\u003c\/b\u003e is installed in the refrigerant circuit and provides a service point for HVAC technicians. It is designed to help isolate the refrigerant circuit during installation, maintenance, charging, recovery, and other approved HVAC service procedures.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features \u0026amp; Function\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eGenuine \u003cb\u003eLennox OEM\u003c\/b\u003e component\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eCat #: 10M23\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eModel \/ Part #: 103881-01\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003e3\/8-inch service valve\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eLiquid line application\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eSMV Series\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eBar-stock valve construction\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eRefrigerant service access\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for outdoor HVAC equipment\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eUsed with select Lennox air conditioners\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eUsed with select Lennox heat pumps\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eOEM replacement service component\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Details \u0026amp; Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eBrand\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eLennox\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCatalog Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e10M23\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eModel \/ Part Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e103881-01\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eService Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSeries\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eSMV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eValve Construction\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eBar-Stock\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eNominal Size\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e3\/8\"\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eLine Application\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eLiquid Line\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eApplication\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eOutdoor HVAC Refrigerant Circuit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eAir Conditioner \/ Heat Pump\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eOEM Component\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Segoe UI Emoji',sans-serif; mso-bidi-font-family: 'Segoe UI Emoji';\"\u003e🛠️\u003c\/span\u003e HVAC Depot Pro Tip\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003e10M23 \/ 103881-01 is a 3\/8-inch liquid line service valve\u003c\/b\u003e. Do not confuse it with the larger \u003cb\u003esuction-line service valve\u003c\/b\u003e that may be installed on the same condenser or heat pump.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBefore ordering, verify:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list .5in;\"\u003e\u003cb\u003eCat # 10M23\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list .5in;\"\u003e\u003cb\u003ePart # 103881-01\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list .5in;\"\u003e\u003cb\u003e3\/8-inch line size\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list .5in;\"\u003eLiquid line application\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list .5in;\"\u003eExisting valve configuration\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list .5in;\"\u003eConnection type\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list .5in;\"\u003eOutdoor unit model number\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list .5in;\"\u003eEquipment serial number\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list .5in;\"\u003eRefrigerant requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eService valves may look very similar externally, so always match the \u003cb\u003eOEM part number and equipment model\u003c\/b\u003e rather than relying only on line size.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment \/ Model Compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eLennox 10M23 \/ 103881-01\u003c\/b\u003e is used with select Lennox outdoor HVAC equipment, including compatible:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo3; tab-stops: list .5in;\"\u003eLennox air conditioners\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo3; tab-stops: list .5in;\"\u003eLennox heat pumps\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo3; tab-stops: list .5in;\"\u003eOutdoor condensing units\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo3; tab-stops: list .5in;\"\u003eCentral air conditioning systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo3; tab-stops: list .5in;\"\u003eSelect \u003cb\u003e13ACX Series\u003c\/b\u003e equipment\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo3; tab-stops: list .5in;\"\u003eSelect \u003cb\u003eXC13 Series\u003c\/b\u003e equipment\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo3; tab-stops: list .5in;\"\u003eOther Lennox systems specifically calling for \u003cb\u003e103881-01\u003c\/b\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eAlways verify the complete equipment model and serial number before ordering.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Lennox","offers":[{"title":"Default Title","offer_id":53972838318443,"sku":"66255147683","price":84.93,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/10M23.jpg?v=1790873520"},{"product_id":"lennox-34w44-100145-07-oem-reversing-valve-1-2-x-3-4-24-vac-solenoid-heat-pump-valve","title":"Lennox 34W44 \/ 100145-07 OEM Reversing Valve – 1\/2\" x 3\/4\", 24 VAC Solenoid, Heat Pump Valve","description":"\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eLennox 34W44\u003c\/b\u003e, model\/part \u003cb\u003e100145-07\u003c\/b\u003e, is a genuine OEM \u003cb\u003ereversing valve with a 24 VAC solenoid\u003c\/b\u003e designed for select Lennox heat pump systems. The valve uses \u003cb\u003e1\/2-inch x 3\/4-inch connections\u003c\/b\u003e and controls refrigerant direction as the heat pump switches between heating and cooling operation.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe reversing valve is a critical component of a heat pump refrigeration circuit. When energized or de-energized by the system controls, it redirects refrigerant flow so the indoor and outdoor coils can change functions between heating and cooling modes.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features \u0026amp; Function\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003eGenuine \u003cb\u003eLennox OEM\u003c\/b\u003e component\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eCat #: 34W44\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eModel \/ Part #: 100145-07\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003eHeat pump reversing valve\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003e1\/2\" x 3\/4\" connections\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003e24 VAC solenoid\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003eElectrically operated refrigerant valve\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003eChanges refrigerant flow direction\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003eSupports heating and cooling operation\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for compatible Lennox heat pump equipment\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo1; tab-stops: list .5in;\"\u003eOEM replacement component\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Details \u0026amp; Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eBrand\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eLennox\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCatalog Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e34W44\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eModel \/ Part Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e100145-07\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eReversing Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eApplication\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHeat Pump\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eConnection Size\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e1\/2\" x 3\/4\"\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSolenoid Voltage\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e24 VAC\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eValve Operation\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eElectrically Actuated\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eFunction\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eReverses Refrigerant Flow\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSystem Operation\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHeating \/ Cooling\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eRefrigeration Circuit\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHeat Pump\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 12; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eOEM Component\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Segoe UI Emoji',sans-serif; mso-bidi-font-family: 'Segoe UI Emoji';\"\u003e🛠️\u003c\/span\u003e HVAC Depot Pro Tip\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eDo not select a reversing valve based only on the tubing diameter.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor the \u003cb\u003e34W44 \/ 100145-07\u003c\/b\u003e, verify:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003e\u003cb\u003eCat # 34W44\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003e\u003cb\u003ePart # 100145-07\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003e\u003cb\u003e1\/2\" x 3\/4\" connection sizes\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003e\u003cb\u003e24 VAC solenoid\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eOutdoor heat pump model\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eRefrigerant type\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eValve orientation and piping configuration\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eOriginal valve specifications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eIf a heat pump operates correctly in one mode but has refrigerant-flow problems when changing between heating and cooling, the reversing valve or its solenoid circuit may require diagnosis. Verify the \u003cb\u003e24 VAC control signal and solenoid operation\u003c\/b\u003e before condemning the complete valve.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment \/ Model Compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eLennox 34W44 \/ 100145-07\u003c\/b\u003e is designed for select Lennox heat pump equipment requiring this specific reversing-valve configuration.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eTypical applications include compatible:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo3; tab-stops: list .5in;\"\u003eLennox heat pumps\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo3; tab-stops: list .5in;\"\u003eResidential split heat pump systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo3; tab-stops: list .5in;\"\u003eOutdoor heat pump units\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo3; tab-stops: list .5in;\"\u003eHeating and cooling refrigeration circuits\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo3; tab-stops: list .5in;\"\u003eEquipment requiring a \u003cb\u003e24 VAC reversing-valve solenoid\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo3; tab-stops: list .5in;\"\u003eLennox systems specifically calling for \u003cb\u003e100145-07\u003c\/b\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eAlways verify the complete equipment model and serial number before ordering.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Lennox","offers":[{"title":"Default Title","offer_id":53972882751851,"sku":"66255139388","price":152.16,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/34W44.jpg?v=1790874684"},{"product_id":"lennox-thermal-expansion-valve-txv-with-3-8-x-1-2-sweat-connections-and-an-external-equalizer","title":"Lennox thermal expansion valve (TXV) with 3\/8\" x 1\/2\" sweat connections and an external equalizer","description":"\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eLennox 79J75\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a genuine OEM \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003ethermal expansion valve (TXV)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e designed for select Lennox HVAC systems. It features \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e3\/8-inch x 1\/2-inch sweat connections\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and an \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eexternally equalized\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e configuration for precise refrigerant metering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eThe TXV regulates refrigerant flow into the evaporator based on system operating conditions, helping maintain proper superheat and efficient heat transfer. The 79J75 is documented in Lennox equipment applications including packaged units, commercial equipment, central air conditioners, and heat pumps. \u003c\/span\u003e\u003cspan class=\"contents\" data-chatgpt-copy-reference=\"1\" data-markdown-copy=\"contents\"\u003e\u003cspan data-state=\"closed\" class=\"contents\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"Heading-Ro3lZr\" dir=\"auto\"\u003e\u003cspan\u003eKey Features \u0026amp; Function\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul dir=\"auto\" class=\"List-kOVW5V UnorderedList-nqKD7g\"\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cspan\u003eGenuine \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eLennox OEM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e component\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003ePart \/ Cat #: 79J75\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cspan\u003eThermal Expansion Valve (\u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eTXV\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e3\/8\" x 1\/2\" connections\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eSweat connection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eExternally equalized\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eControls refrigerant flow into the evaporator\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eHelps maintain proper evaporator superheat\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eUsed in select Lennox HVAC equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eSuitable for applicable air conditioning and heat pump systems\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"Heading-Ro3lZr\" dir=\"auto\"\u003e\u003cspan\u003eProduct Details \u0026amp; Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"group\/app-widget pointer-coarse:pt-11 [@media(hover:none)]:pt-11 TableContainer-UfIOz_\" data-markdown-table=\"true\" data-wide-block=\"\" tabindex=\"-1\"\u003e\n\u003cdiv class=\"TableScroller-ZhMTLB\"\u003e\n\u003cdiv class=\"TableWrapper-i1mUIE\"\u003e\n\u003ctable class=\"Table-LqdUhs\" dir=\"auto\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003cth class=\"TableHeaderCell-esYSpn SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth class=\"TableHeaderCell-esYSpn SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody class=\"TableBody-A5sMNL\"\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cspan\u003eLennox\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e79J75\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cspan\u003eThermal Expansion Valve\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eCommon Name\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cspan\u003eTXV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eConnection Size\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e3\/8\" x 1\/2\"\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eConnection Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eSweat\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eEqualizer\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eExternal\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eFunction\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cspan\u003eRefrigerant Metering\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eApplication\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cspan\u003eHVAC Refrigeration Circuit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eOEM Component\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"absolute end-0 top-0 z-50 flex w-fit select-none items-center gap-1 rounded-full bg-surface p-0.5 text-tertiary pointer-events-none opacity-0 group-hover\/app-widget:pointer-events-auto group-hover\/app-widget:opacity-100 focus-within:pointer-events-auto focus-within:opacity-100 data-[visible=true]:pointer-events-auto data-[visible=true]:opacity-100 has-data-[state=open]:pointer-events-auto has-data-[state=open]:opacity-100 pointer-coarse:pointer-events-auto pointer-coarse:opacity-100 [@media(hover:none)]:pointer-events-auto [@media(hover:none)]:opacity-100\" data-block-actions=\"true\" data-markdown-copy=\"exclude\"\u003e\n\u003cspan data-state=\"closed\" class=\"contents\"\u003e\u003cbutton type=\"button\" class=\"no-drag cursor-interaction items-center select-none disabled:cursor-default aria-disabled:cursor-default focus:outline-hidden disabled:opacity-40 aria-disabled:opacity-40 focus-visible:ring-2 focus-visible:ring-ring focus-visible:ring-offset-0 whitespace-nowrap flex border gap-1 rounded-full text-tertiary not-disabled:not-aria-disabled:hover:bg-primary-ghost-hover not-disabled:not-aria-disabled:hover:text-default data-[state=open]:bg-primary-ghost-hover border-transparent size-9 justify-center border-0 p-0\"\u003e\u003cspan class=\"LeadingSource-d79mNZ\"\u003e\u003c\/span\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan data-state=\"closed\" class=\"contents\"\u003e\u003cbutton type=\"button\" class=\"no-drag cursor-interaction items-center select-none disabled:cursor-default aria-disabled:cursor-default focus:outline-hidden disabled:opacity-40 aria-disabled:opacity-40 focus-visible:ring-2 focus-visible:ring-ring focus-visible:ring-offset-0 whitespace-nowrap flex border gap-1 rounded-full text-tertiary not-disabled:not-aria-disabled:hover:bg-primary-ghost-hover not-disabled:not-aria-disabled:hover:text-default data-[state=open]:bg-primary-ghost-hover border-transparent size-9 justify-center border-0 p-0\"\u003e\u003cspan class=\"LeadingSource-d79mNZ\"\u003e\u003csvg class=\"Icon-X4VkKC\" height=\"20\" viewbox=\"0 0 20 20\" width=\"20\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003c\/button\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eThe connection dimensions and TXV configuration are consistently identified across current parts sources. \u003c\/span\u003e\u003cspan class=\"contents\" data-chatgpt-copy-reference=\"2\" data-markdown-copy=\"contents\"\u003e\u003cspan data-state=\"closed\" class=\"contents\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"Heading-Ro3lZr\" dir=\"auto\"\u003e\u003cspan\u003e🛠️ HVAC Depot Pro Tip\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eDo not select the \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e79J75\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e simply because another TXV has the same tubing sizes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eBefore ordering, verify:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul dir=\"auto\" class=\"List-kOVW5V UnorderedList-nqKD7g\"\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003ePart # 79J75\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eRefrigerant used by the equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eIndoor and outdoor equipment model\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eRequired TXV capacity\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e3\/8\" x 1\/2\" sweat connections\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eExternal equalizer requirement\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eDistributor configuration\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eManufacturer charging specifications\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eThis is especially important because the \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e79J75 appears in multiple Lennox equipment families and capacities\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, so the equipment model should determine compatibility rather than tubing size alone.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"Heading-Ro3lZr\" dir=\"auto\"\u003e\u003cspan\u003eEquipment \/ Model Compatibility\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eDocumented applications for the \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eLennox 79J75\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e include select:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul dir=\"auto\" class=\"List-kOVW5V UnorderedList-nqKD7g\"\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eCHA16 Series\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e packaged units\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eLGA Series\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e equipment\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eLGC Series\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e equipment\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eLSA Series\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e central air conditioners\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eLHA Series\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e heat pumps\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eGCS equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cspan\u003eOther Lennox equipment specifically calling for \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e79J75\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eExamples documented in parts information include \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eCHA16-072-1, CHA16-120-1, CHA16-180-1, CHA16-240-1, LSA090P-1, and LHA120H-1\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan class=\"contents\" data-chatgpt-copy-reference=\"3\" data-markdown-copy=\"contents\"\u003e\u003cspan data-state=\"closed\" class=\"contents\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eAlways verify the complete equipment model and serial number before ordering.\u003c\/span\u003e\u003c\/p\u003e","brand":"Lennox","offers":[{"title":"Default Title","offer_id":53973527789931,"sku":"66255117082","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/79J75_cbb01bea-cb8d-4865-ad3b-842c23afad50.jpg?v=1790889196"},{"product_id":"lennox-26k34-lb-85663j-oem-txv-expansion-valve-kit-r-22-1-5-to-3-ton-air-conditioning-systems","title":"Lennox 26K34 \/ LB-85663J OEM TXV Expansion Valve Kit – R-22, 1.5 to 3 Ton Air Conditioning Systems","description":"\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eLennox 26K34\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, model\/part \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eLB-85663J\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, is a genuine OEM \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003ethermal expansion valve (TXV) kit\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e designed for compatible \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e1.5 to 3 ton R-22 air conditioning systems\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Lennox identifies the 26K34 specifically as an indoor R-22 TXV kit covering the 1.5–3 ton range. \u003c\/span\u003e\u003cspan class=\"contents\" data-chatgpt-copy-reference=\"0\" data-markdown-copy=\"contents\"\u003e\u003cspan data-state=\"closed\" class=\"contents\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eThe TXV regulates liquid refrigerant flow entering the evaporator coil according to system operating conditions. Correct refrigerant metering helps maintain proper evaporator superheat, cooling capacity, and system performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"Heading-Ro3lZr\" dir=\"auto\"\u003e\u003cspan\u003eKey Features \u0026amp; Function\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul dir=\"auto\" class=\"List-kOVW5V UnorderedList-nqKD7g\"\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cspan\u003eGenuine \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eLennox OEM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e component\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eCat #: 26K34\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eModel \/ Part #: LB-85663J\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cspan\u003eThermal Expansion Valve (\u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eTXV\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e) kit\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cspan\u003eDesigned for \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eR-22 refrigerant\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e1.5 to 3 ton\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e capacity range\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eIndoor evaporator-coil application\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eRefrigerant metering device\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eHelps maintain proper evaporator superheat\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eDesigned for compatible Lennox air conditioning systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eKit includes TXV and installation components\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eLennox installation documentation identifies \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e26K34 \/ LB-85663J\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for -018, -024, -030, and -036 applications and specifies that the kit includes the TXV, two Teflon rings, a sensing-bulb mounting strap, and mounting hardware.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eThe R-22 refrigerant, 1.5–3 ton range, indoor designation, LB-85663J part number, and UPC are listed in Lennox's product specifications. \u003c\/span\u003e\u003cspan class=\"contents\" data-chatgpt-copy-reference=\"2\" data-markdown-copy=\"contents\"\u003e\u003cspan data-state=\"closed\" class=\"contents\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"Heading-Ro3lZr\" dir=\"auto\"\u003e\u003cspan\u003e🛠️ HVAC Depot Pro Tip\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eDo not choose a TXV based only on system tonnage. For this valve, match:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eCat #: \u003c\/span\u003e\u003cspan data-markdown-copy=\"inline-code\" class=\"InlineCode-Cddi3Y InlineMarkdownIsolate-QWDV4W\" dir=\"ltr\"\u003e26K34\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003ePart #: \u003c\/span\u003e\u003cspan data-markdown-copy=\"inline-code\" class=\"InlineCode-Cddi3Y InlineMarkdownIsolate-QWDV4W\" dir=\"ltr\"\u003eLB-85663J\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eRefrigerant: R-22\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eCapacity: 1.5–3 Ton\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eApplication: Air Conditioning\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eThis is especially important because Lennox also used other TXV kits for larger R-22 equipment. For example, Lennox installation documentation assigns \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e26K34 to -018 through -036 applications\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e26K35\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is specified for -042, -048, and -060 applications. \u003c\/span\u003e\u003cspan class=\"contents\" data-chatgpt-copy-reference=\"3\" data-markdown-copy=\"contents\"\u003e\u003cspan data-state=\"closed\" class=\"contents\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center font-sans select-none relative top-[-0.094rem] translate-y-0.5\" data-search-result-target=\"\"\u003e\u003ca data-testid=\"chatgpt-citation\" class=\"no-underline! group cursor-interaction hover:bg-secondary-soft-hover hover:text-default! flex h-4.5 max-w-[15rem] overflow-hidden rounded-xl pe-2 ps-1 text-[9px] leading-none font-medium select-none bg-secondary-soft text-secondary-solid!\" href=\"https:\/\/assets.unilogcorp.com\/267\/ITEM\/DOC\/Lennox_100484_07_Manual.pdf?utm_source=chatgpt.com\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cspan class=\"relative start-0 bottom-0 flex h-full w-full items-center\"\u003e\u003cspan class=\"flex min-w-0 flex-1 items-center gap-1\"\u003e\u003cspan class=\"Favicon-xZwQNw inline-block shrink-0 rounded-2xs size-3 overflow-hidden rounded-full text-current [\u0026amp;\u0026gt;img]:rounded-full size-3 overflow-hidden rounded-full text-current [\u0026amp;\u0026gt;img]:rounded-full\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eBefore ordering, verify the outdoor condenser model, indoor coil or air-handler model, R-22 refrigerant, required TXV kit, and manufacturer charging specifications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"Heading-Ro3lZr\" dir=\"auto\"\u003e\u003cspan\u003eEquipment \/ Model Compatibility\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eLennox 26K34 \/ LB-85663J\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is documented for numerous Lennox R-22 indoor coil and air-handler combinations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eExamples include select:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul dir=\"auto\" class=\"List-kOVW5V UnorderedList-nqKD7g\"\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eC33 Series\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e evaporator coils\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eCR33 Series\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e coils\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eCH33 Series\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e horizontal coils\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eCB26UH Series\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e air handlers\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eCB29M Series\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e air handlers\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eCB30U Series\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e air handlers\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cspan\u003eLennox \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e13ACD\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e R-22 air-conditioning combinations\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eLennox engineering data specifically identifies 26K34 in multiple 1.5-, 2-, 2.5-, and 3-ton equipment combinations. \u003c\/span\u003e\u003cspan class=\"contents\" data-chatgpt-copy-reference=\"4\" data-markdown-copy=\"contents\"\u003e\u003cspan data-state=\"closed\" class=\"contents\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center font-sans select-none relative top-[-0.094rem] translate-y-0.5\" data-search-result-target=\"\"\u003e\u003ca data-testid=\"chatgpt-citation\" class=\"no-underline! group cursor-interaction hover:bg-secondary-soft-hover hover:text-default! flex h-4.5 max-w-[15rem] overflow-hidden rounded-xl pe-2 ps-1 text-[9px] leading-none font-medium select-none bg-secondary-soft text-secondary-solid!\" href=\"https:\/\/tech.lennoxintl.com\/C03e7o14l\/VIu12Ch2uV\/ehb_cr33_ariratings_all_0510.pdf?utm_source=chatgpt.com\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cspan class=\"relative start-0 bottom-0 flex h-full w-full items-center\"\u003e\u003cspan class=\"flex min-w-0 flex-1 items-center gap-1\"\u003e\u003cspan class=\"Favicon-xZwQNw inline-block shrink-0 rounded-2xs size-3 overflow-hidden rounded-full text-current [\u0026amp;\u0026gt;img]:rounded-full size-3 overflow-hidden rounded-full text-current [\u0026amp;\u0026gt;img]:rounded-full\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eAlways verify the complete indoor and outdoor equipment model numbers before ordering.\u003c\/span\u003e\u003c\/p\u003e","brand":"Lennox","offers":[{"title":"Default Title","offer_id":53973947646315,"sku":"26K34","price":152.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/26K34.jpg?v=1790897698"},{"product_id":"lennox-49w62-603113-01-oem-reversing-valve-replacement-kit-24-vac-1-2-x-7-8-solenoid-wiring-harness","title":"Lennox 49W62 \/ 603113-01 OEM Reversing Valve Replacement Kit – 24 VAC, 1\/2\" x 7\/8\", Solenoid \u0026 Wiring Harness","description":"\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eLennox 49W62\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, model\/part \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e603113-01\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, is a genuine OEM \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003ereversing valve replacement kit\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e designed for select Lennox heat pump systems. The complete kit includes the reversing valve, \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e24 VAC solenoid coil\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, wiring harness, and installation instructions. \u003c\/span\u003e\u003cspan class=\"contents\" data-chatgpt-copy-reference=\"0\" data-markdown-copy=\"contents\"\u003e\u003cspan data-state=\"closed\" class=\"contents\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eThe reversing valve changes the direction of refrigerant flow when a heat pump switches between heating and cooling operation. This kit is designed as a direct service replacement for compatible factory-installed Lennox reversing valves.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"Heading-Ro3lZr\" dir=\"auto\"\u003e\u003cspan\u003eKey Features \u0026amp; Function\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul dir=\"auto\" class=\"List-kOVW5V UnorderedList-nqKD7g\"\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cspan\u003eGenuine \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eLennox OEM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e replacement kit\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eCat #: 49W62\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eModel \/ Part #: 603113-01\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eReversing valve replacement kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e24 VAC solenoid\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e50\/60 Hz\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e1\/2\" compressor discharge connection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e7\/8\" outdoor coil connection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e7\/8\" compressor suction connection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e7\/8\" vapor line service-valve connection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003ePreassembled solenoid and wiring harness\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eControls refrigerant direction\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eEnables heat pump heating\/cooling changeover\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eDesigned for select Lennox heat pumps\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eThe valve and connection specifications are documented for this kit, including the 1\/2-inch discharge and 7\/8-inch suction\/vapor connections.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"Heading-Ro3lZr\" dir=\"auto\"\u003e\u003cspan\u003eKit Includes\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul dir=\"auto\" class=\"List-kOVW5V UnorderedList-nqKD7g\"\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e100145-09 \/ 42W59\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Reversing Valve\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e101813-01 \/ 42W18\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Solenoid Coil\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e100273-07 \/ 42W62\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Wiring Harness\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eInstallation instructions\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eThese components are listed by Lennox as the contents of the \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e603113-01 \/ 49W62\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e replacement kit. \u003c\/span\u003e\u003cspan class=\"contents\" data-chatgpt-copy-reference=\"2\" data-markdown-copy=\"contents\"\u003e\u003cspan data-state=\"closed\" class=\"contents\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"Heading-Ro3lZr\" dir=\"auto\"\u003e\u003cspan\u003e🛠️ HVAC Depot Pro Tip\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e49W62 is a complete replacement kit\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, not just the bare reversing valve.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eThe actual reversing valve included in the kit is:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eValve: \u003c\/span\u003e\u003cspan data-markdown-copy=\"inline-code\" class=\"InlineCode-Cddi3Y InlineMarkdownIsolate-QWDV4W\" dir=\"ltr\"\u003e100145-09\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eValve Cat #: \u003c\/span\u003e\u003cspan data-markdown-copy=\"inline-code\" class=\"InlineCode-Cddi3Y InlineMarkdownIsolate-QWDV4W\" dir=\"ltr\"\u003e42W59\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eThe complete kit is:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eKit Cat #: \u003c\/span\u003e\u003cspan data-markdown-copy=\"inline-code\" class=\"InlineCode-Cddi3Y InlineMarkdownIsolate-QWDV4W\" dir=\"ltr\"\u003e49W62\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eKit Part #: \u003c\/span\u003e\u003cspan data-markdown-copy=\"inline-code\" class=\"InlineCode-Cddi3Y InlineMarkdownIsolate-QWDV4W\" dir=\"ltr\"\u003e603113-01\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eSolenoid: 24 VAC\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eConnections: 1\/2\" discharge \/ 7\/8\" suction-vapor\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eThis distinction is useful when a customer is searching for either \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e49W62\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e603113-01\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e42W59\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, or \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e100145-09\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eBefore ordering, verify the outdoor unit model, original valve configuration, tubing sizes, refrigerant application, solenoid voltage, and complete equipment serial number.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"Heading-Ro3lZr\" dir=\"auto\"\u003e\u003cspan\u003eEquipment \/ Model Compatibility\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eLennox 49W62 \/ 603113-01\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is used in numerous Lennox heat pump applications. Documented examples include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul dir=\"auto\" class=\"List-kOVW5V UnorderedList-nqKD7g\"\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e13HPD036\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e13HPD042\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e13HPD048\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e13HPX036\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e13HPX048\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eXP13 Series\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eXP14 Series\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eXP16 Series\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eXP19 Series\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eTPA Series\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eSPA Series\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cspan\u003eOther Lennox equipment specifically calling for \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e49W62\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eFor example, the kit appears in parts information for the \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eXP1903623002\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e heat pump and multiple 13HPD\/13HPX configurations. \u003c\/span\u003e\u003cspan class=\"contents\" data-chatgpt-copy-reference=\"3\" data-markdown-copy=\"contents\"\u003e\u003cspan data-state=\"closed\" class=\"contents\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eAlways verify the complete model and serial number before ordering\u003c\/span\u003e\u003c\/p\u003e","brand":"Lennox","offers":[{"title":"Default Title","offer_id":53977282511211,"sku":"66255139763","price":207.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/49W62.jpg?v=1790953892"},{"product_id":"lennox-49k03-041239-07-oem-txv-expansion-valve-r-22-3-ton-external-equalizer","title":"Lennox 49K03 \/ 041239-07 OEM TXV Expansion Valve – R-22, 3 Ton, External Equalizer","description":"\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eLennox 49K03\u003c\/b\u003e, model\/part \u003cb\u003e041239-07\u003c\/b\u003e, is a genuine OEM \u003cb\u003ethermal expansion valve (TXV)\u003c\/b\u003e designed for select Lennox air handlers and evaporator coil applications.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis expansion valve is designed for \u003cb\u003eR-22 refrigerant\u003c\/b\u003e and \u003cb\u003e3-ton HVAC applications\u003c\/b\u003e. The TXV regulates refrigerant flow entering the evaporator coil based on system operating conditions, helping maintain proper superheat, cooling capacity, and overall system performance.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features \u0026amp; Function\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eGenuine \u003cb\u003eLennox OEM\u003c\/b\u003e component\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eCat #: 49K03\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eModel \/ Part #: 041239-07\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eThermal Expansion Valve (\u003cb\u003eTXV\u003c\/b\u003e)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for \u003cb\u003eR-22 refrigerant\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e3 Ton\u003c\/b\u003e nominal application\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eApproximately \u003cb\u003e36,000 BTU\u003c\/b\u003e nominal capacity class\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eExternally equalized design\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eControls refrigerant flow into the evaporator coil\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eHelps maintain proper evaporator superheat\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for compatible Lennox indoor HVAC equipment\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eSuitable for select air-handler and evaporator-coil applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Details \u0026amp; Key Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eBrand\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eLennox\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCatalog Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e49K03\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eModel \/ Part Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e041239-07\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eThermal Expansion Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCommon Name\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eTXV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eRefrigerant\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eR-22\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eNominal Capacity\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e3 Ton\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eNominal Capacity Class\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e36,000 BTU\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEqualizer Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eExternal\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eApplication\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eAir Handler \/ Evaporator Coil\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eFunction\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eRefrigerant Metering\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 12; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eOEM Component\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Segoe UI Emoji',sans-serif; mso-bidi-font-family: 'Segoe UI Emoji';\"\u003e🛠️\u003c\/span\u003e HVAC Depot Pro Tip\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWhen replacing a TXV, \u003cb\u003edo not match the valve by tonnage alone\u003c\/b\u003e. A 3-ton R-410A expansion valve is not automatically interchangeable with a 3-ton R-22 valve.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor this part, verify:\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCatalog Number: 49K03\u003c\/b\u003e\u003cbr\u003e\u003cb\u003ePart Number: 041239-07\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eRefrigerant: R-22\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eNominal Capacity: 3 Ton\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eValve Type: TXV \/ Thermal Expansion Valve\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eEqualizer: External\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eAlso verify the complete indoor coil or air-handler model and the outdoor condenser model before ordering. The refrigerant, capacity, connection configuration, distributor arrangement, and manufacturer charging requirements should all match the original system.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment \/ Model Compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eLennox 49K03 \/ 041239-07\u003c\/b\u003e is designed for select Lennox \u003cb\u003eR-22 air handlers and evaporator coil systems\u003c\/b\u003e requiring this specific TXV.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eDocumented applications include select equipment from families such as:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003e\u003cb\u003eLennox CB28UH Series\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003e\u003cb\u003eLennox CB29M Series\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eLennox R-22 air handlers\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eLennox R-22 evaporator coil applications\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003e3-ton systems specifically calling for \u003cb\u003e49K03\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eEquipment specifically calling for \u003cb\u003e041239-07\u003c\/b\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eBecause Lennox used different expansion valves depending on equipment size, refrigerant, and coil configuration, always verify the \u003cb\u003ecomplete model and serial number\u003c\/b\u003e before ordering.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Lennox","offers":[{"title":"Default Title","offer_id":53977305153899,"sku":"66255131241","price":192.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/49K03.jpg?v=1790954452"},{"product_id":"lennox-26k35-lb-85663k-oem-txv-kit-r-22-air-conditioning-3-5-to-5-ton-thermal-expansion-valve","title":"Lennox 26K35 \/ LB-85663K OEM TXV Kit – R-22 Air Conditioning, 3.5 to 5 Ton Thermal Expansion Valve","description":"\u003ch1 class=\"MsoNormal\"\u003e\u003cb\u003eLennox 26K35 \/ LB-85663K OEM TXV Kit – R-22 Air Conditioning, 3.5 to 5 Ton Thermal Expansion Valve\u003c\/b\u003e\u003c\/h1\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eLennox 26K35\u003c\/b\u003e, model\/part \u003cb\u003eLB-85663K\u003c\/b\u003e, is a genuine Lennox \u003cb\u003ethermal expansion valve (TXV) kit\u003c\/b\u003e designed for compatible \u003cb\u003eR-22 air conditioning systems from 3.5 to 5 tons\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe TXV regulates refrigerant flow entering the indoor evaporator coil according to system operating conditions. Proper refrigerant metering helps maintain correct evaporator superheat, cooling capacity, efficiency, and overall system performance.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features \u0026amp; Function\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eGenuine \u003cb\u003eLennox OEM\u003c\/b\u003e TXV kit\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eCat #: 26K35\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eModel \/ Part #: LB-85663K\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eThermal Expansion Valve (\u003cb\u003eTXV\u003c\/b\u003e) kit\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for \u003cb\u003eR-22 refrigerant\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eAir conditioning application\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e3.5 to 5 Ton\u003c\/b\u003e system range\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eCovers nominal \u003cb\u003e42,000–60,000 BTU\u003c\/b\u003e equipment\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eIndoor evaporator application\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eControls refrigerant flow into the evaporator coil\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eHelps maintain proper evaporator superheat\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for compatible Lennox coils and air handlers\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eUsed with select \u003cb\u003e-042, -048 and -060\u003c\/b\u003e equipment sizes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Details \u0026amp; Key Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eBrand\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eLennox\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCatalog Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e26K35\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eModel \/ Part Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eLB-85663K\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eTXV Kit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eValve Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eThermal Expansion Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eRefrigerant\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eR-22\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSystem Capacity\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e3.5–5 Ton\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eNominal BTU Range\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e42,000–60,000 BTU\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment Sizes\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e-042, -048, -060\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eApplication\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eAir Conditioning\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eInstallation Location\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eIndoor \/ Evaporator\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 12;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eFunction\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eRefrigerant Metering\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 13; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eOEM Component\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKit Components\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eLB-85663K TXV kit\u003c\/b\u003e includes the components required for the applicable TXV installation, including:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eThermal expansion valve\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eTeflon sealing rings\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eSensing-bulb mounting strap\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eMounting hardware\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Segoe UI Emoji',sans-serif; mso-bidi-font-family: 'Segoe UI Emoji';\"\u003e🛠️\u003c\/span\u003e HVAC Depot Pro Tip\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003e26K35 \/ LB-85663K is specifically intended for R-22 air-conditioning applications\u003c\/b\u003e. Do not select a TXV based on tonnage alone.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify:\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCatalog Number: 26K35\u003c\/b\u003e\u003cbr\u003e\u003cb\u003ePart Number: LB-85663K\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eRefrigerant: R-22\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eApplication: Air Conditioning\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eCapacity: 3.5–5 Ton\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eEquipment Sizes: -042, -048 \u0026amp; -060\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eAn important distinction when stocking these Lennox TXVs:\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e26K34 \/ LB-85663J:\u003c\/b\u003e R-22 A\/C, \u003cb\u003e1.5–3 Ton\u003c\/b\u003e\u003cbr\u003e\u003cb\u003e26K35 \/ LB-85663K:\u003c\/b\u003e R-22 A\/C, \u003cb\u003e3.5–5 Ton\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBefore ordering, verify the outdoor condenser model, indoor evaporator coil or air-handler model, refrigerant type, required TXV, and manufacturer charging specifications.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment \/ Model Compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eLennox 26K35 \/ LB-85663K\u003c\/b\u003e is designed for select Lennox \u003cb\u003eR-22 air-conditioning systems\u003c\/b\u003e within the 3.5-to-5-ton range.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eTypical applications include:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003e\u003cb\u003e-042 \/ 3.5 Ton\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003e\u003cb\u003e-048 \/ 4 Ton\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003e\u003cb\u003e-060 \/ 5 Ton\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eSelect Lennox evaporator coils\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eSelect Lennox air handlers\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eSelect Lennox \u003cb\u003eCH33 Series\u003c\/b\u003e coils\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eR-22 air-conditioning systems requiring \u003cb\u003e26K35\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eEquipment specifically calling for \u003cb\u003eLB-85663K\u003c\/b\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eAlways verify the complete indoor and outdoor equipment model numbers before ordering.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Lennox","offers":[{"title":"Default Title","offer_id":53977344311659,"sku":"66255135515","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/26K35.jpg?v=1790956514"},{"product_id":"lennox-24l18-150943-038-oem-thermal-expansion-valve-txv-hvac-refrigerant-metering-valve","title":"Lennox 24L18 \/ 150943-038 OEM Thermal Expansion Valve TXV – HVAC Refrigerant Metering Valve","description":"\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eLennox 24L18\u003c\/b\u003e, model\/part \u003cb\u003e150943-038\u003c\/b\u003e, is a genuine Lennox OEM \u003cb\u003ethermal expansion valve (TXV)\u003c\/b\u003e designed for select Lennox HVAC and refrigeration applications.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe expansion valve regulates the amount of refrigerant entering the evaporator coil according to system operating conditions. Correct TXV operation helps maintain proper evaporator superheat, cooling capacity, and overall system performance.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features \u0026amp; Function\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eGenuine \u003cb\u003eLennox OEM\u003c\/b\u003e component\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eCat #: 24L18\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eModel \/ Part #: 150943-038\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eThermal Expansion Valve (\u003cb\u003eTXV\u003c\/b\u003e)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eRefrigerant metering component\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eControls refrigerant entering the evaporator\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eHelps maintain proper evaporator superheat\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for select Lennox HVAC equipment\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eFactory replacement component\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eUsed across multiple Lennox equipment models\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Details \u0026amp; Key Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eBrand\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eLennox\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCatalog Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e24L18\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eModel \/ Part Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e150943-038\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eExpansion Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCommon Name\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eTXV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eFunction\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eRefrigerant Metering\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eApplication\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHVAC Refrigeration Circuit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eOEM Component\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eGross Weight\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e0.85 lb\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Segoe UI Emoji',sans-serif; mso-bidi-font-family: 'Segoe UI Emoji';\"\u003e🛠️\u003c\/span\u003e HVAC Depot Pro Tip\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor the \u003cb\u003e24L18 \/ 150943-038\u003c\/b\u003e, do not select a replacement TXV based only on appearance or connection size.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify:\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCatalog Number: 24L18\u003c\/b\u003e\u003cbr\u003e\u003cb\u003ePart Number: 150943-038\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eComponent: Thermal Expansion Valve \/ TXV\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe exact \u003cb\u003erefrigerant, capacity, connection sizes, and equipment application should be verified from the unit model and serial number\u003c\/b\u003e before installation. I would not advertise a specific tonnage or refrigerant for this valve unless it is confirmed for the exact equipment application.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment \/ Model Compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eLennox 24L18 \/ 150943-038\u003c\/b\u003e is used in multiple Lennox equipment applications requiring this specific expansion valve.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor correct compatibility, verify:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eComplete equipment model number\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eEquipment serial number\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eOriginal TXV part number\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eRefrigerant type\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eSystem capacity\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eInlet and outlet connection sizes\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eExternal\/internal equalizer configuration\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eManufacturer charging specifications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eEquipment specifically calling for \u003cb\u003e24L18\u003c\/b\u003e or \u003cb\u003e150943-038\u003c\/b\u003e should be matched by the factory parts information before ordering.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Lennox","offers":[{"title":"Default Title","offer_id":53977373999467,"sku":"66255130308","price":205.74,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/24L18.jpg?v=1790958380"},{"product_id":"lennox-38m74-150839-007-oem-txv-expansion-valve-r-410a-6-ton-nominal-capacity","title":"Lennox 38M74 \/ 150839-007 OEM TXV Expansion Valve – R-410A, 6 Ton Nominal Capacity","description":"\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eLennox 38M74\u003c\/b\u003e, model\/part \u003cb\u003e150839-007\u003c\/b\u003e, is a genuine Lennox OEM \u003cb\u003ethermal expansion valve (TXV)\u003c\/b\u003e designed for compatible \u003cb\u003eR-410A HVAC systems with a nominal 6-ton capacity\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis expansion valve meters liquid refrigerant entering the evaporator coil according to system operating conditions. Proper TXV operation helps maintain correct evaporator superheat, refrigerant flow, cooling capacity, and overall system performance.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features \u0026amp; Function\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eGenuine \u003cb\u003eLennox OEM\u003c\/b\u003e component\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eCat #: 38M74\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eModel \/ Part #: 150839-007\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eThermal Expansion Valve (\u003cb\u003eTXV\u003c\/b\u003e)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for \u003cb\u003eR-410A refrigerant\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003e6 Ton nominal capacity\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eApproximately \u003cb\u003e72,000 BTU\u003c\/b\u003e nominal capacity class\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eRefrigerant metering device\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eControls refrigerant flow into the evaporator\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eHelps maintain proper evaporator superheat\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for compatible Lennox HVAC equipment\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eSuitable for equipment specifically requiring \u003cb\u003e38M74 \/ 150839-007\u003c\/b\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Details \u0026amp; Key Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eBrand\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eLennox\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCatalog Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e38M74\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eModel \/ Part Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e150839-007\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eThermal Expansion Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCommon Name\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eTXV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eRefrigerant\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eR-410A\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eNominal Capacity\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e6 Ton\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eNominal BTU Class\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e72,000 BTU\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eFunction\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eRefrigerant Metering\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eApplication\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eEvaporator \/ HVAC Refrigeration Circuit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eOEM Component\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Segoe UI Emoji',sans-serif; mso-bidi-font-family: 'Segoe UI Emoji';\"\u003e🛠️\u003c\/span\u003e HVAC Depot Pro Tip\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eDo not choose a replacement TXV based only on the \u003cb\u003e6-ton capacity\u003c\/b\u003e. The valve must also match the refrigerant and equipment configuration.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor this valve, verify:\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCatalog Number: 38M74\u003c\/b\u003e\u003cbr\u003e\u003cb\u003ePart Number: 150839-007\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eRefrigerant: R-410A\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eNominal Capacity: 6 Ton \/ 72,000 BTU\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eComponent: Thermal Expansion Valve \/ TXV\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBefore ordering, verify the complete indoor and outdoor equipment model numbers, refrigerant type, original TXV number, connection configuration, equalizer arrangement, and manufacturer charging specifications.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment \/ Model Compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eLennox 38M74 \/ 150839-007\u003c\/b\u003e is intended for select Lennox \u003cb\u003eR-410A HVAC equipment\u003c\/b\u003e requiring a nominal 6-ton expansion valve.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eTypical applications include:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eSelect Lennox commercial HVAC equipment\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eSelect Lennox R-410A air-conditioning systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eSelect Lennox R-410A heat-pump applications where specified\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eEvaporator coil applications\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003e\u003cb\u003e6-ton \/ 72,000 BTU nominal systems\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eEquipment specifically calling for \u003cb\u003e38M74\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eEquipment specifically calling for \u003cb\u003e150839-007\u003c\/b\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eAlways verify the complete equipment \u003cb\u003emodel and serial number\u003c\/b\u003e before ordering.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Lennox","offers":[{"title":"Default Title","offer_id":53977444450667,"sku":"66255145640","price":207.52,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/38M74.jpg?v=1790959742"},{"product_id":"lennox-60m99-151331-015-oem-txv-thermal-expansion-valve-r-410a-refrigerant-metering-valve","title":"Lennox 60M99 \/ 151331-015 OEM TXV Thermal Expansion Valve – R-410A Refrigerant Metering Valve","description":"\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eLennox 60M99\u003c\/b\u003e, model\/part \u003cb\u003e151331-015\u003c\/b\u003e, is a genuine Lennox OEM \u003cb\u003ethermal expansion valve (TXV)\u003c\/b\u003e designed for compatible \u003cb\u003eR-410A HVAC systems\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe TXV regulates the amount of liquid refrigerant entering the evaporator coil based on system operating conditions. Proper refrigerant metering helps maintain correct evaporator superheat, cooling capacity, efficiency, and reliable system operation.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features \u0026amp; Function\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eGenuine \u003cb\u003eLennox OEM\u003c\/b\u003e component\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eCat #: 60M99\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eModel \/ Part #: 151331-015\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eThermal Expansion Valve (\u003cb\u003eTXV\u003c\/b\u003e)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for \u003cb\u003eR-410A refrigerant\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eRefrigerant metering device\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eRegulates refrigerant entering the evaporator\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eHelps maintain proper evaporator superheat\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for select Lennox HVAC equipment\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eFactory replacement expansion valve\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eSuitable for equipment specifically requiring \u003cb\u003e60M99 \/ 151331-015\u003c\/b\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Details \u0026amp; Key Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eBrand\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eLennox\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCatalog Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e60M99\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eModel \/ Part Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e151331-015\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eThermal Expansion Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCommon Name\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eTXV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eRefrigerant\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eR-410A\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eFunction\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eRefrigerant Metering\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eApplication\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eEvaporator \/ Refrigeration Circuit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHVAC Equipment\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eOEM Component\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Segoe UI Emoji',sans-serif; mso-bidi-font-family: 'Segoe UI Emoji';\"\u003e🛠️\u003c\/span\u003e HVAC Depot Pro Tip\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eDo not select a replacement TXV based only on its physical appearance. The valve must match the \u003cb\u003erefrigerant, capacity, connection configuration, and equipment application\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor this valve, verify:\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCatalog Number: 60M99\u003c\/b\u003e\u003cbr\u003e\u003cb\u003ePart Number: 151331-015\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eRefrigerant: R-410A\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eComponent: Thermal Expansion Valve \/ TXV\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe exact tonnage should be verified against the equipment model and factory parts information before advertising or installing this valve. A TXV with the same refrigerant type is not automatically interchangeable.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment \/ Model Compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eLennox 60M99 \/ 151331-015\u003c\/b\u003e is designed for select Lennox \u003cb\u003eR-410A HVAC equipment\u003c\/b\u003e requiring this specific factory expansion valve.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBefore ordering, verify:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eComplete equipment model number\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eSerial number\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eOriginal TXV part number\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003e\u003cb\u003eR-410A refrigerant\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eSystem capacity\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eTXV inlet and outlet connection sizes\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eEqualizer configuration\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eDistributor configuration\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eManufacturer charging specifications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eEquipment specifically calling for \u003cb\u003e60M99\u003c\/b\u003e or \u003cb\u003e151331-015\u003c\/b\u003e should be matched using the factory parts information.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Lennox","offers":[{"title":"Default Title","offer_id":53977627361643,"sku":"66255141032","price":207.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/60M99.jpg?v=1790963819"},{"product_id":"factory-authorized-parts-340620-720-oem-txv-kit-replacement-hvac-thermal-expansion-valve-kit","title":"Factory Authorized Parts 340620-720 OEM TXV Kit Replacement – HVAC Thermal Expansion Valve Kit","description":"\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eFactory Authorized Parts™ 340620-720\u003c\/b\u003e is an OEM \u003cb\u003eTXV replacement kit\u003c\/b\u003e designed for compatible HVAC equipment requiring this specific factory thermal expansion valve assembly.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe thermal expansion valve controls refrigerant flow entering the evaporator coil in response to system operating conditions. Proper TXV operation helps maintain the correct evaporator superheat, cooling performance, and refrigerant flow through the system.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features \u0026amp; Function\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eGenuine \u003cb\u003eFactory Authorized Parts™\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eItem #: 340620-720\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eMFR #: 340620-720\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eOEM TXV replacement kit\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eThermal Expansion Valve (\u003cb\u003eTXV\u003c\/b\u003e) application\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eRefrigerant metering component\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eControls refrigerant entering the evaporator coil\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eHelps maintain proper evaporator superheat\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned as a factory service replacement\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eFor compatible HVAC equipment specifically requiring \u003cb\u003e340620-720\u003c\/b\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Details \u0026amp; Key Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eBrand\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eFactory Authorized Parts™\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eItem Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e340620-720\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eManufacturer Part Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e340620-720\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eTXV Replacement Kit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eValve Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eThermal Expansion Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eFunction\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eRefrigerant Metering\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eApplication\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eEvaporator \/ HVAC Refrigeration Circuit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eReplacement Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eFactory Authorized OEM Service Part\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eOEM Component\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Segoe UI Emoji',sans-serif; mso-bidi-font-family: 'Segoe UI Emoji';\"\u003e🛠️\u003c\/span\u003e HVAC Depot Pro Tip\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor the \u003cb\u003e340620-720\u003c\/b\u003e, match the complete factory part number before ordering:\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eItem #: 340620-720\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eMFR #: 340620-720\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eComponent: TXV Replacement Kit\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eDo not choose a replacement TXV based only on its appearance or tubing size. The correct valve must match the equipment's \u003cb\u003erefrigerant, capacity, evaporator coil, connection configuration, equalizer arrangement, and factory application\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBefore installation, verify the complete equipment model and serial number against \u003cb\u003e340620-720\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment \/ Model Compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eFactory Authorized Parts 340620-720\u003c\/b\u003e should be used with compatible HVAC equipment specifically identified for this factory TXV kit.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBefore ordering, verify:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eComplete equipment model number\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eSerial number\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eOriginal TXV or kit number\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eRefrigerant type\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eSystem capacity\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eIndoor evaporator coil\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eTXV inlet and outlet connections\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eEqualizer configuration\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eFactory charging specifications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eBecause TXV specifications can vary substantially between otherwise similar equipment, \u003cb\u003e340620-720 should be matched by the factory part number whenever possible\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Carrier","offers":[{"title":"Default Title","offer_id":53978384925035,"sku":"781897033325","price":211.66,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/340620-720.jpg?v=1790971558"},{"product_id":"factory-authorized-parts-332368-755-oem-thermostatic-expansion-valve-txv-kit-hvac-refrigerant-metering-kit","title":"Factory Authorized Parts 332368-755 OEM Thermostatic Expansion Valve (TXV) Kit – HVAC Refrigerant Metering Kit","description":"\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eFactory Authorized Parts™ 332368-755\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is an OEM \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eThermostatic Expansion Valve (TXV) Kit\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e designed for compatible HVAC equipment requiring this specific factory refrigerant metering assembly.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe TXV regulates refrigerant flow into the evaporator coil according to system operating conditions. Correct refrigerant metering helps maintain proper evaporator superheat, cooling capacity, system efficiency, and reliable compressor operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features \u0026amp; Function\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eGenuine \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eFactory Authorized Parts™\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eItem #: 332368-755\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eMFR #: 332368-755\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eOEM Thermostatic Expansion Valve (\u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eTXV\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e) Kit\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRefrigerant metering component\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRegulates refrigerant entering the evaporator coil\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHelps maintain proper evaporator superheat\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSupports efficient HVAC system operation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFactory-authorized service replacement\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDesigned for compatible air-conditioning and heat-pump equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eFor equipment specifically requiring \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e332368-755\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Details \u0026amp; Key Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFactory Authorized Parts™\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eItem Number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e332368-755\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eManufacturer Part Number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e332368-755\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThermostatic Expansion Valve Kit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCommon Name\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTXV Kit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFunction\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRefrigerant Metering\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eApplication\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEvaporator \/ HVAC Refrigeration Circuit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eReplacement Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFactory Authorized OEM Service Part\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eOEM Component\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003e🛠️ HVAC Depot Pro Tip\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eFor the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e332368-755\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, match the complete factory part number rather than selecting a TXV based only on physical appearance or connection size.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eVerify:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eItem #: \u003c\/span\u003e\u003ccode dir=\"ltr\"\u003e332368-755\u003c\/code\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eMFR #: \u003c\/span\u003e\u003ccode dir=\"ltr\"\u003e332368-755\u003c\/code\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eComponent: Thermostatic Expansion Valve (TXV) Kit\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBefore ordering, confirm the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003erefrigerant type, system capacity, indoor coil model, outdoor equipment model, TXV connection sizes, equalizer configuration, and factory charging specifications\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDo not assume \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e332368-755\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e332368-763\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e are interchangeable simply because both are Factory Authorized Parts TXV kits. The complete part number and equipment application should match.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eEquipment \/ Model Compatibility\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eFactory Authorized Parts 332368-755\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is intended for compatible HVAC equipment specifically requiring this factory TXV kit.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBefore ordering, verify:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eComplete HVAC equipment model number\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEquipment serial number\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndoor evaporator coil model\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOutdoor condenser or heat-pump model\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOriginal TXV or kit number\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRefrigerant type\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNominal system capacity\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTXV inlet and outlet connections\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEqualizer configuration\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDistributor configuration\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eManufacturer charging requirements\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eFor the safest replacement, confirm the factory equipment information specifically calls for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e332368-755\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"Default Title","offer_id":53988583276907,"sku":"0822529139265","price":348.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/332368-755.jpg?v=1791221071"},{"product_id":"factory-authorized-parts-332368-754-oem-thermal-expansion-valve-txv-kit-hvac-refrigerant-metering-kit","title":"Factory Authorized Parts 332368-754 OEM Thermal Expansion Valve (TXV) Kit – HVAC Refrigerant Metering Kit","description":"\u003ch1 class=\"MsoNormal\"\u003eFactory Authorized Parts 332368-754 OEM Thermal Expansion Valve (TXV) Kit – HVAC Refrigerant Metering Kit\u003c\/h1\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eFactory Authorized Parts™ 332368-754\u003c\/b\u003e is an OEM \u003cb\u003eThermal Expansion Valve (TXV) Kit\u003c\/b\u003e designed for compatible HVAC equipment requiring this specific factory refrigerant metering assembly.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe TXV regulates refrigerant flow entering the evaporator coil according to system operating conditions. Proper refrigerant metering helps maintain correct evaporator superheat, cooling performance, system efficiency, and reliable compressor operation.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features \u0026amp; Function\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eGenuine \u003cb\u003eFactory Authorized Parts™\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eItem #: 332368-754\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eMFR #: 332368-754\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eOEM Thermal Expansion Valve (\u003cb\u003eTXV\u003c\/b\u003e) Kit\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eRefrigerant metering component\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eRegulates refrigerant flow into the evaporator coil\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eHelps maintain proper evaporator superheat\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eSupports efficient cooling-system operation\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eFactory-authorized HVAC service replacement\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for compatible air-conditioning and heat-pump equipment\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eFor equipment specifically requiring \u003cb\u003e332368-754\u003c\/b\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Details \u0026amp; Key Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eBrand\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eFactory Authorized Parts™\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eItem Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e332368-754\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eManufacturer Part Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e332368-754\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eThermal Expansion Valve Kit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCommon Name\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eTXV Kit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eFunction\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eRefrigerant Metering\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eApplication\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eEvaporator \/ HVAC Refrigeration Circuit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eReplacement Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eFactory Authorized OEM Service Part\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eOEM Component\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Segoe UI Emoji',sans-serif; mso-bidi-font-family: 'Segoe UI Emoji';\"\u003e🛠️\u003c\/span\u003e HVAC Depot Pro Tip\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor the \u003cb\u003e332368-754\u003c\/b\u003e, match the complete factory part number rather than selecting a TXV based only on its physical appearance or tubing size.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify:\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eItem #: 332368-754\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eMFR #: 332368-754\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eComponent: Thermal Expansion Valve (TXV) Kit\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBefore ordering, confirm the \u003cb\u003erefrigerant type, equipment capacity, indoor coil model, outdoor unit model, connection sizes, equalizer configuration, distributor arrangement, and factory charging requirements\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eDo not assume \u003cb\u003e332368-754\u003c\/b\u003e, \u003cb\u003e332368-755\u003c\/b\u003e, and \u003cb\u003e332368-763\u003c\/b\u003e are interchangeable because their part numbers and descriptions are similar. Each kit should be matched to the specific equipment application.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment \/ Model Compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eFactory Authorized Parts 332368-754\u003c\/b\u003e is intended for compatible HVAC equipment specifically requiring this factory TXV kit.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBefore ordering, verify:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eComplete HVAC equipment model number\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eEquipment serial number\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eIndoor evaporator coil model\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eOutdoor condenser or heat-pump model\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eOriginal TXV or kit number\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eRefrigerant type\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eNominal system capacity\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eTXV inlet and outlet connections\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eEqualizer configuration\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eDistributor configuration\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eManufacturer charging specifications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eFor the safest replacement match, confirm the factory equipment documentation specifically calls for \u003cb\u003e332368-754\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Carier","offers":[{"title":"Default Title","offer_id":53995443192171,"sku":"822529139258","price":291.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/332368-754.jpg?v=1791301996"},{"product_id":"factory-authorized-parts-332368-774-oem-txv-replacement-kit-hvac-thermal-expansion-valve-refrigerant-metering-kit","title":"Factory Authorized Parts 332368-774 OEM TXV Replacement Kit – HVAC Thermal Expansion Valve Refrigerant Metering Kit","description":"\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eFactory Authorized Parts™ 332368-774\u003c\/b\u003e is an OEM \u003cb\u003eTXV replacement kit\u003c\/b\u003e designed for compatible HVAC equipment requiring this specific factory refrigerant metering assembly.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe thermal expansion valve regulates refrigerant flow entering the evaporator coil based on system operating conditions. Proper TXV operation helps maintain correct evaporator superheat, cooling capacity, system efficiency, and reliable compressor operation.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features \u0026amp; Function\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eGenuine \u003cb\u003eFactory Authorized Parts™\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eItem #: 332368-774\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eMFR #: 332368-774\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eOEM TXV replacement kit\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eThermal Expansion Valve (\u003cb\u003eTXV\u003c\/b\u003e) application\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eRefrigerant metering component\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eRegulates refrigerant entering the evaporator coil\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eHelps maintain proper evaporator superheat\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eFactory-authorized HVAC service replacement\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for compatible air-conditioning and heat-pump equipment\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eFor equipment specifically requiring \u003cb\u003e332368-774\u003c\/b\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Details \u0026amp; Key Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eBrand\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eFactory Authorized Parts™\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eItem Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e332368-774\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eManufacturer Part Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e332368-774\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eTXV Replacement Kit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eValve Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eThermal Expansion Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eFunction\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eRefrigerant Metering\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eApplication\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eEvaporator \/ HVAC Refrigeration Circuit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eReplacement Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eFactory Authorized OEM Service Part\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eOEM Component\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Segoe UI Emoji',sans-serif; mso-bidi-font-family: 'Segoe UI Emoji';\"\u003e🛠️\u003c\/span\u003e HVAC Depot Pro Tip\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eMatch the \u003cb\u003e332368-774\u003c\/b\u003e using the complete factory part number. Do not select a TXV based only on physical appearance, tonnage, or tubing diameter.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify:\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eItem #: 332368-774\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eMFR #: 332368-774\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eComponent: TXV Replacement Kit\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBefore ordering or installing, confirm the \u003cb\u003erefrigerant type, system capacity, evaporator coil model, outdoor equipment model, connection sizes, equalizer configuration, distributor arrangement, and factory charging specifications\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eDo not assume \u003cb\u003e332368-774\u003c\/b\u003e is interchangeable with other Factory Authorized Parts 332368-series TXV kits. Similar part numbers can represent different equipment applications and valve configurations.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment \/ Model Compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eFactory Authorized Parts 332368-774\u003c\/b\u003e is intended for compatible HVAC equipment specifically requiring this factory TXV replacement kit.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBefore ordering, verify:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eComplete equipment model number\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eEquipment serial number\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eIndoor evaporator coil model\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eOutdoor condenser or heat-pump model\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eOriginal TXV or kit number\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eRefrigerant type\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eNominal system capacity\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eTXV inlet and outlet connections\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eEqualizer configuration\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eDistributor configuration\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eManufacturer charging specifications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eFor the safest match, confirm that the factory equipment documentation specifically identifies \u003cb\u003e332368-774\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Carrier","offers":[{"title":"Default Title","offer_id":53995539038571,"sku":"822529603131","price":407.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/332368-774.jpg?v=1791304600"},{"product_id":"factory-authorized-parts-332368-753-oem-txv-kit-1-5-2-5-ton-r-410a-3-8-mf-x-3-8-90-sweat","title":"Factory Authorized Parts 332368-753 OEM TXV Kit – 1.5–2.5 Ton, R-410A, 3\/8\" MF x 3\/8\" 90° Sweat","description":"\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eFactory Authorized Parts™ 332368-753\u003c\/b\u003e is an OEM \u003cb\u003ethermostatic expansion valve (TXV) kit\u003c\/b\u003e designed for compatible \u003cb\u003e1.5 to 2.5 ton R-410A HVAC systems\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis TXV regulates the amount of R-410A refrigerant entering the evaporator coil to help maintain proper superheat and efficient system operation. It features a \u003cb\u003e3\/8\" MF x 3\/8\" 90-degree sweat connection configuration\u003c\/b\u003e and is intended for equipment specifically requiring factory part \u003cb\u003e332368-753\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features \u0026amp; Function\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eGenuine \u003cb\u003eFactory Authorized Parts™\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eItem #: 332368-753\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eMFR #: 332368-753\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eThermostatic Expansion Valve (\u003cb\u003eTXV\u003c\/b\u003e) Kit\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e1.5–2.5 ton\u003c\/b\u003e system application\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for \u003cb\u003eR-410A refrigerant\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e3\/8\" MF x 3\/8\"\u003c\/b\u003e connection configuration\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e90° sweat\u003c\/b\u003e connection\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eControls refrigerant flow into the evaporator coil\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eHelps maintain proper evaporator superheat\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eFactory-authorized HVAC service replacement\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for compatible air-conditioning and heat-pump applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Details \u0026amp; Key Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eBrand\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eFactory Authorized Parts™\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eItem Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e332368-753\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eManufacturer Part Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e332368-753\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eThermostatic Expansion Valve Kit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCommon Name\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eTXV Kit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eRefrigerant\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eR-410A\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSystem Capacity\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e1.5–2.5 Ton\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eBTU Class\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e18,000–30,000 BTU\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eConnection\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e3\/8\" MF x 3\/8\"\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eConnection Style\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e90° Sweat\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eFunction\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eRefrigerant Metering\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 12;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eApplication\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eEvaporator Coil \/ HVAC Refrigeration Circuit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 13; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eOEM Component\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Segoe UI Emoji',sans-serif; mso-bidi-font-family: 'Segoe UI Emoji';\"\u003e🛠️\u003c\/span\u003e HVAC Depot Pro Tip\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003e332368-753\u003c\/b\u003e should be matched by more than tonnage alone. Before ordering, verify all of these key specifications:\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003ePart Number: 332368-753\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eRefrigerant: R-410A\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eCapacity: 1.5–2.5 Ton\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eConnection: 3\/8\" MF x 3\/8\"\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eConfiguration: 90° Sweat\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eDo not assume another 1.5–2.5 ton TXV will work simply because it uses R-410A. Connection configuration, valve capacity, equalizer arrangement, distributor design, and equipment application must also match.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment \/ Model Compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eFactory Authorized Parts 332368-753\u003c\/b\u003e is intended for compatible \u003cb\u003e1.5 to 2.5 ton R-410A HVAC systems\u003c\/b\u003e specifically requiring this factory TXV kit.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eTypical applications include:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003e\u003cb\u003e1.5-ton R-410A systems\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003e\u003cb\u003e2-ton R-410A systems\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003e\u003cb\u003e2.5-ton R-410A systems\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eCompatible evaporator coils\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eCompatible air handlers\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eSplit-system air conditioners\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eHeat-pump applications where specified\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eEquipment requiring \u003cb\u003e332368-753\u003c\/b\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eAlways verify the indoor coil and outdoor unit model numbers before ordering.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Carrier","offers":[{"title":"Default Title","offer_id":53995616272747,"sku":"822529139241","price":276.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/332368-753.jpg?v=1791305268"},{"product_id":"factory-authorized-parts™-ef17bz113-reversing-valve-item-ef17bz113-mfr-ef17bz113","title":"Factory Authorized Parts™ - EF17BZ113 Reversing Valve Item: EF17BZ113 MFR: EF17BZ113","description":"\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eFactory Authorized Parts™ EF17BZ113\u003c\/b\u003e is an OEM \u003cb\u003ereversing valve\u003c\/b\u003e designed for compatible heat-pump HVAC equipment requiring this specific factory replacement component.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe reversing valve changes the direction of refrigerant flow within a heat-pump system, allowing the equipment to switch between \u003cb\u003ecooling and heating modes\u003c\/b\u003e. The \u003cb\u003eEF17BZ113\u003c\/b\u003e is intended as a factory-authorized service replacement for equipment specifically calling for this part number.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features \u0026amp; Function\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eGenuine \u003cb\u003eFactory Authorized Parts™\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eItem #: EF17BZ113\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eMFR #: EF17BZ113\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eOEM heat-pump reversing valve\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eControls refrigerant flow direction\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eAllows heat pump to switch between heating and cooling\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003ePart of the HVAC refrigeration circuit\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for compatible heat-pump systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eFactory-authorized service replacement\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eExact OEM part number simplifies replacement identification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Details \u0026amp; Key Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eBrand\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eFactory Authorized Parts™\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eItem Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEF17BZ113\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eManufacturer Part Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEF17BZ113\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eReversing Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eApplication\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHeat Pump\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eFunction\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eRefrigerant Flow Direction Control\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSystem Function\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHeating \/ Cooling Mode Changeover\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCircuit\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHVAC Refrigeration Circuit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eReplacement Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eFactory Authorized OEM Service Part\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eOEM Component\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Segoe UI Emoji',sans-serif; mso-bidi-font-family: 'Segoe UI Emoji';\"\u003e🛠️\u003c\/span\u003e HVAC Depot Pro Tip\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eDo not select a reversing valve based only on its physical appearance. Before ordering \u003cb\u003eEF17BZ113\u003c\/b\u003e, verify:\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003ePart Number: EF17BZ113\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eComponent: Heat Pump Reversing Valve\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eAlso confirm the \u003cb\u003erefrigerant type, valve connection sizes, system capacity, solenoid voltage, valve orientation, piping configuration, and complete equipment model\/serial number\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eReversing valves that appear physically similar may have different capacities, connection sizes, pilot configurations, or solenoid requirements.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment \/ Model Compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eFactory Authorized Parts EF17BZ113\u003c\/b\u003e is designed for compatible heat-pump equipment specifically requiring this factory reversing valve.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBefore ordering, verify:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eComplete heat-pump model number\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eEquipment serial number\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eOriginal reversing valve number\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003e\n\u003cb\u003eEF17BZ113\u003c\/b\u003e factory part number\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eRefrigerant type\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eSystem tonnage\/capacity\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eSuction and discharge connection sizes\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eCoil connection sizes\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eSolenoid voltage\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eValve orientation and piping configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eFor the safest replacement match, confirm the equipment's factory parts information specifically identifies \u003cb\u003eEF17BZ113\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Carrier","offers":[{"title":"Default Title","offer_id":53995790008683,"sku":"662442650641","price":523.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/EF17BZ113.jpg?v=1791316831"},{"product_id":"factory-authorized-parts-kganp4601all-natural-gas-to-propane-lp-conversion-kit-oem-furnace-gas-conversion-kit","title":"Factory Authorized Parts KGANP4601ALL Natural Gas to Propane (LP) Conversion Kit – OEM Furnace Gas Conversion Kit","description":"\u003cp class=\"MsoNormal\"\u003eThe KGANP4601ALL Natural Gas to Propane Conversion Kit is an OEM HVAC service kit designed to convert compatible gas-fired heating equipment from natural gas to liquid propane (LP) when approved by the equipment manufacturer.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis conversion kit is intended for furnaces and heating systems specifically identified for KGANP4601ALL. Proper fuel conversion helps ensure that the gas-fired equipment operates according to its approved propane specifications.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe kit is designed for qualified HVAC technicians performing manufacturer-approved natural gas to propane conversions.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features \u0026amp; Function\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eItem #: KGANP4601ALL\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eMFR #: KGANP4601ALL\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eNatural gas to propane conversion kit\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eConverts approved equipment from NG to LP\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for compatible gas-fired HVAC heating systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eFactory-specified service conversion component\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eSupports proper propane fuel configuration when installed according to manufacturer instructions\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eIntended for qualified HVAC service professionals\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eEquipment-specific application\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eExact part number for conversion-kit identification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Details \u0026amp; Key Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eProduct Name\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eNatural Gas to Propane Conversion Kit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eManufacturer Part Number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eKGANP4601ALL\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eItem Number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eKGANP4601ALL\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eProduct Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eGas Conversion Kit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eConversion Direction\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eNatural Gas to Propane\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eOriginal Fuel\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eNatural Gas (NG)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eConverted Fuel\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eLiquid Propane (LP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eApplication\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eCompatible Gas-Fired HVAC Equipment\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eInstallation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eProfessional Installation Required\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eKit Contents\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify manufacturer packaging\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eEquipment Compatibility\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eModel-Specific\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Segoe UI Emoji',sans-serif; mso-bidi-font-family: 'Segoe UI Emoji';\"\u003e🛠️\u003c\/span\u003e HVAC Depot Pro Tip\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe KGANP4601ALL is specifically identified as a natural gas-to-propane conversion kit. It should not be used for propane-to-natural-gas conversions.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBefore ordering, verify:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eComplete furnace model and serial number\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eManufacturer approval for LP conversion\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eConversion kit number KGANP4601ALL\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eRequired burner orifices and regulator components\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eManufacturer-specified LP gas pressure\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eAltitude-related conversion requirements, where applicable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eImportant: Fuel conversions must be performed by a qualified HVAC technician following the manufacturer's conversion instructions. Proper gas-pressure adjustment, leak testing, combustion analysis, and conversion labeling are essential.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment \/ Model Compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe KGANP4601ALL is intended for compatible gas-fired heating equipment specifically approved for conversion using this kit.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003ePotential equipment applications include manufacturer-approved:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eResidential gas furnaces\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eGas-fired HVAC heating systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eNatural-gas furnace installations being converted to LP\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eEquipment specifically requiring KGANP4601ALL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eCompatibility Note: Exact furnace model compatibility, kit contents, and manufacturer-specific conversion requirements have not been independently verified. Confirm the complete equipment model and serial number before purchasing.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Carrier","offers":[{"title":"Default Title","offer_id":54016370508139,"sku":"1PKGANP4601ALL","price":228.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/KGANP4601ALL.jpg?v=1791473008"},{"product_id":"trane-american-standard-val08882-oem-switchover-valve-4-ton-heat-pump-reversing-valve-with-solenoid-coil","title":"Trane \/ American Standard VAL08882 OEM Switchover Valve – 4 Ton Heat Pump Reversing Valve with Solenoid Coil","description":"\u003cp class=\"MsoNormal\"\u003eThe Trane \/ American Standard VAL08882 is an OEM 4-ton switchover valve assembly designed for compatible heat pump systems. This valve includes the solenoid coil and is used to control refrigerant flow direction as the heat pump switches between heating and cooling operation.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe VAL08882 is designed for HVAC service and replacement applications requiring this specific factory valve assembly. Its switchover function allows compatible heat pumps to reverse the refrigeration cycle and provide both heating and cooling.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features \u0026amp; Function\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eGenuine Trane \/ American Standard OEM replacement part\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003ePart Number: VAL08882\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e4-ton nominal capacity\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eSwitchover \/ reversing valve assembly\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eIncludes solenoid coil\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eControls refrigerant flow direction\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eEnables heating and cooling mode changes\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for compatible heat pump applications\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eFactory replacement refrigeration component\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eIntended for equipment specifically requiring VAL08882\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Details \u0026amp; Key Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eBrand\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eTrane \/ American Standard\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eManufacturer Part Number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVAL08882\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eProduct Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eSwitchover Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eCommon Name\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHeat Pump Reversing Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eNominal Capacity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e4 Ton\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eBTU Class\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e48,000 BTU\/hr\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eSolenoid Coil\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eIncluded\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003ePrimary Function\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eRefrigerant Flow Direction Control\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eSystem Operation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHeating \/ Cooling Changeover\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eApplication\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHeat Pump Refrigeration Circuit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eReplacement Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eOEM Service Part\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 12;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eCoil Voltage\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify equipment specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 13;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eRefrigerant Compatibility\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify equipment specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 14; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eConnection Sizes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify factory specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Segoe UI Emoji',sans-serif; mso-bidi-font-family: 'Segoe UI Emoji';\"\u003e🛠️\u003c\/span\u003e HVAC Depot Pro Tip\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWhen replacing the Trane VAL08882, verify the complete part number and equipment application before ordering.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003ePart Number: VAL08882\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eCapacity: 4 Ton\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eComponent: Switchover \/ Reversing Valve\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eSolenoid Coil: Included\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eDo not match a reversing valve based only on its 4-ton rating. The replacement must also match the refrigerant type, solenoid voltage, valve connection sizes, flow capacity, and piping configuration.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBecause VAL08882 includes the solenoid coil, verify whether the original equipment requires the complete valve assembly rather than a replacement coil alone.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eInstallation requires proper refrigerant recovery, brazing procedures, evacuation, leak testing, and system performance verification by a qualified HVAC technician.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment \/ Model Compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Trane \/ American Standard VAL08882 is intended for compatible 4-ton heat pump systems specifically requiring this factory switchover valve assembly.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBefore ordering, verify:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eComplete heat pump model number\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eEquipment serial number\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eOriginal reversing valve part number\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eVAL08882 factory part number\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eNominal 4-ton system capacity\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eRefrigerant type\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eSolenoid coil voltage\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eValve connection sizes\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003ePiping orientation\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eManufacturer service documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eCompatibility Note: Exact equipment model compatibility and valve connection specifications have not been independently confirmed.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Trane \/ American Standard","offers":[{"title":"Default Title","offer_id":54016430014827,"sku":"VAL08882","price":200.74,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/VAL08882.jpg?v=1791476863"},{"product_id":"trane-american-standard-val06385-oem-thermostatic-expansion-valve-txv-5-ton-1-2-female-ods-inlet","title":"Trane \/ American Standard VAL06385 OEM Thermostatic Expansion Valve (TXV) – 5 Ton, 1\/2\" Female ODS Inlet","description":"\u003cp class=\"MsoNormal\"\u003eThe Trane \/ American Standard VAL06385 is an OEM thermostatic expansion valve (TXV) designed for compatible 5-ton HVAC refrigeration systems. Featuring a 1\/2-inch female ODS inlet connection, this valve regulates refrigerant flow entering the evaporator coil to help maintain proper system operation.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe VAL06385 responds to evaporator operating conditions to control refrigerant metering and maintain appropriate superheat. Proper TXV operation supports cooling performance, system efficiency, and compressor protection.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis factory replacement component is intended for HVAC equipment specifically requiring VAL06385.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features \u0026amp; Function\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eGenuine Trane \/ American Standard OEM replacement component\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003ePart Number: VAL06385\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eThermostatic Expansion Valve (TXV)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e5-ton nominal capacity\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e1\/2\" Female ODS inlet\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eRefrigerant metering control\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eRegulates refrigerant entering the evaporator coil\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eHelps maintain proper evaporator superheat\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eSupports efficient cooling operation\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for compatible HVAC refrigeration applications\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eFactory replacement expansion valve\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Details \u0026amp; Key Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eBrand\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eTrane \/ American Standard\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eManufacturer Part Number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVAL06385\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eProduct Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eThermostatic Expansion Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eCommon Name\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eTXV \/ Expansion Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eNominal Capacity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e5 Ton\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eCapacity Class\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e60,000 BTU\/hr\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eInlet Size\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e1\/2\"\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eInlet Connection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eFemale ODS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eFunction\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eRefrigerant Metering\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eApplication\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHVAC Evaporator \/ Refrigeration Circuit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eReplacement Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eOEM Service Component\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 12;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eRefrigerant Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify manufacturer specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 13;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eOutlet Connection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify manufacturer specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 14; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eEqualizer Configuration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify manufacturer specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Segoe UI Emoji',sans-serif; mso-bidi-font-family: 'Segoe UI Emoji';\"\u003e🛠️\u003c\/span\u003e HVAC Depot Pro Tip\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWhen replacing the Trane VAL06385, verify the complete manufacturer part number rather than selecting a TXV based only on its tonnage.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003ePart Number: VAL06385\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eNominal Capacity: 5 Ton\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eInlet Connection: 1\/2\" Female ODS\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eComponent: Thermostatic Expansion Valve (TXV)\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eA 5-ton TXV is not automatically compatible with every 5-ton HVAC system. Refrigerant type, inlet and outlet connections, equalizer configuration, distributor arrangement, and equipment design must all match.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eImportant: Refrigerant compatibility has not been independently confirmed for this specific valve. Verify the manufacturer's specifications before advertising it for R-22, R-410A, or other refrigerants.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment \/ Model Compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Trane \/ American Standard VAL06385 is intended for compatible HVAC equipment requiring this specific 5-ton thermostatic expansion valve.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003ePotential applications include:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eCompatible Trane evaporator coils\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eCompatible American Standard evaporator coils\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eSelect 5-ton air-conditioning systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eSelect 5-ton heat-pump systems where specified\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eHVAC equipment requiring VAL06385\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eBefore ordering, verify the complete indoor and outdoor equipment model numbers, serial numbers, refrigerant type, and original TXV identification.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Trane \/ American Standard","offers":[{"title":"Default Title","offer_id":54016434602347,"sku":"VAL06385","price":198.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/VAL06385.jpg?v=1791477345"},{"product_id":"trane-american-standard-val08719-oem-thermostatic-expansion-valve-txv-3-ton-3-8-female-sweat-brazed-inlet-permanent-strainer","title":"Trane \/ American Standard VAL08719 OEM Thermostatic Expansion Valve (TXV) – 3 Ton, 3\/8\" Female Sweat\/Brazed Inlet, Permanent Strainer","description":"\u003cp class=\"MsoNormal\"\u003eThe Trane \/ American Standard VAL08719 is an OEM thermostatic expansion valve (TXV) designed for compatible 3-ton HVAC air-conditioning and refrigeration systems. Featuring a 3\/8-inch female sweat\/brazed inlet and a permanent strainer, this valve regulates refrigerant flow entering the evaporator coil to help maintain proper cooling performance.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe VAL08719 controls refrigerant metering according to evaporator operating conditions, helping maintain appropriate superheat, efficient heat transfer, and reliable compressor operation.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis factory replacement valve is intended for compatible HVAC equipment specifically requiring VAL08719.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features \u0026amp; Function\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eGenuine Trane \/ American Standard OEM replacement component\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003ePart Number: VAL08719\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eThermostatic Expansion Valve (TXV)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e3-ton nominal capacity\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e3\/8\" female sweat\/brazed inlet\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003ePermanent strainer\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eRegulates refrigerant entering the evaporator coil\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eHelps maintain proper evaporator superheat\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eSupports efficient HVAC cooling performance\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eRefrigerant metering component\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for compatible air-conditioning and heat-pump equipment where specified\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eFactory replacement expansion valve\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Details \u0026amp; Key Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eBrand\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eTrane \/ American Standard\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eManufacturer Part Number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVAL08719\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eProduct Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eThermostatic Expansion Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eCommon Name\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eTXV \/ Expansion Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eNominal Capacity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e3 Ton\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eCapacity Class\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e36,000 BTU\/hr\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eInlet Size\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e3\/8\"\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eInlet Connection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eFemale Sweat \/ Brazed\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eStrainer\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003ePermanent Strainer\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003ePrimary Function\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eRefrigerant Metering\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eApplication\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHVAC Evaporator \/ Refrigeration Circuit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 12;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eReplacement Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eOEM Service Component\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 13;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eRefrigerant Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify factory specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 14;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eOutlet Connection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify factory specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 15; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eEqualizer Configuration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify factory specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Segoe UI Emoji',sans-serif; mso-bidi-font-family: 'Segoe UI Emoji';\"\u003e🛠️\u003c\/span\u003e HVAC Depot Pro Tip\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWhen replacing the Trane VAL08719, match the exact OEM part number and valve configuration rather than selecting a TXV based only on its 3-ton capacity.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003ePart Number: VAL08719\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eNominal Capacity: 3 Ton\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eInlet Connection: 3\/8\" Female Sweat\/Brazed\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eStrainer: Permanent\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eComponent: Thermostatic Expansion Valve (TXV)\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe permanent strainer helps capture debris before it enters the metering valve. During installation, protect the valve from excessive brazing heat and follow the manufacturer's procedures.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eA 3-ton TXV is not automatically compatible with every 3-ton HVAC system. Verify refrigerant type, outlet connection, equalizer arrangement, and equipment compatibility before purchasing.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment \/ Model Compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Trane \/ American Standard VAL08719 is intended for compatible HVAC equipment specifically requiring this factory 3-ton thermostatic expansion valve.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003ePotential applications include:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list .5in;\"\u003eCompatible Trane evaporator coils\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list .5in;\"\u003eCompatible American Standard evaporator coils\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list .5in;\"\u003eSelect 3-ton air-conditioning systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list .5in;\"\u003eSelect 3-ton heat-pump applications where specified\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list .5in;\"\u003eHVAC equipment requiring VAL08719\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eBefore ordering, verify:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eComplete indoor equipment model number\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eOutdoor condenser or heat-pump model\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eEquipment serial numbers\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eOriginal TXV part number\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eRefrigerant type\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003e3\/8\" inlet connection\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eOutlet connection dimensions\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eEqualizer configuration\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eFactory charging specifications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eCompatibility Note: Exact equipment model compatibility and refrigerant type have not been independently confirmed for VAL08719.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Trane \/ American Standard","offers":[{"title":"Default Title","offer_id":54016443253099,"sku":"VAL08719","price":245.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/VAL08719.jpg?v=1791477765"},{"product_id":"trane-american-standard-val08224-oem-heat-pump-reversing-valve-7-8-odf-discharge-x-1-3-8-odf-suction-includes-col11873-solenoid-coil","title":"Trane \/ American Standard VAL08224 OEM Heat Pump Reversing Valve – 7\/8\" ODF Discharge x 1-3\/8\" ODF Suction, Includes COL11873 Solenoid Coil","description":"\u003cp class=\"MsoNormal\"\u003eThe Trane \/ American Standard VAL08224 is an OEM heat pump reversing valve designed for compatible Trane and American Standard heat pump systems. This valve features a 7\/8-inch ODF discharge connection and a 1-3\/8-inch ODF suction connection and includes the COL11873 solenoid coil.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe VAL08224 controls refrigerant flow direction, allowing a compatible heat pump to switch between heating and cooling modes. As a key component of the refrigeration circuit, the reversing valve helps ensure proper system operation and heating and cooling performance.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis factory replacement valve includes the solenoid coil but does not include the wire harness. It is intended for equipment specifically requiring Trane part number VAL08224.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features \u0026amp; Function\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eGenuine Trane \/ American Standard OEM replacement part\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003ePart Number: VAL08224\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eHeat pump reversing \/ switchover valve\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e7\/8\" ODF discharge connection\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e1-3\/8\" ODF suction connection\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eIncludes solenoid coil COL11873\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eWire harness not included\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eControls refrigerant flow direction\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eEnables heating and cooling mode changeover\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for compatible heat pump refrigeration circuits\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eFactory replacement reversing valve assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Details \u0026amp; Key Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eBrand\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eTrane \/ American Standard\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eManufacturer Part Number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVAL08224\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eProduct Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHeat Pump Reversing Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eCommon Name\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e4-Way Reversing Valve \/ Switchover Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eDischarge Connection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e7\/8\" ODF (0.88\")\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eSuction Connection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e1-3\/8\" ODF (1.38\")\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eConnection Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eODF \/ Sweat-Brazed\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eSolenoid Coil\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eIncluded\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eSolenoid Coil Part Number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eCOL11873\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eWire Harness\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eNot Included\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003ePrimary Function\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eRefrigerant Flow Reversal\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 12;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eSystem Application\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHeat Pump Heating and Cooling\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 13;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eReplacement Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eOEM Service Component\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 14;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eSolenoid Voltage\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify manufacturer specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 15;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eRefrigerant Compatibility\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify equipment specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 16;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eNominal Tonnage\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify equipment specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 17; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eInstallation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eProfessional HVAC Installation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Segoe UI Emoji',sans-serif; mso-bidi-font-family: 'Segoe UI Emoji';\"\u003e🛠️\u003c\/span\u003e HVAC Depot Pro Tip\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWhen replacing the Trane VAL08224, verify the refrigerant connections and included components before ordering.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003ePart Number: VAL08224\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eDischarge Connection: 7\/8\" ODF\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eSuction Connection: 1-3\/8\" ODF\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIncluded Solenoid Coil: COL11873\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWire Harness: Not Included\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe COL11873 solenoid coil is included, but the wire harness must be reused or obtained separately if required.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eDo not select a reversing valve based only on pipe diameter. Confirm the equipment model, refrigerant, solenoid voltage, valve orientation, and factory application.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eReversing valve installation requires proper refrigerant recovery, heat protection during brazing, evacuation, leak testing, and system performance verification by a qualified HVAC technician.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment \/ Model Compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Trane \/ American Standard VAL08224 is intended for compatible heat pump equipment specifically requiring this OEM reversing valve assembly.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003ePotential applications include:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eCompatible Trane heat pump systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eCompatible American Standard heat pump systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eHVAC equipment requiring VAL08224\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eRefrigeration circuits designed for the specified 7\/8\" discharge and 1-3\/8\" suction connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eBefore ordering, verify the complete equipment model and serial numbers, original reversing valve part number, solenoid coil requirements, refrigerant type, and piping configuration.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eCompatibility Note: Exact equipment model numbers, refrigerant ratings, and nominal system capacity have not been independently confirmed.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Trane \/ American Standard","offers":[{"title":"Default Title","offer_id":54016452428139,"sku":"VAL08224","price":270.19,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/VAL08224.jpg?v=1791478460"},{"product_id":"trane-american-standard-val08884-oem-switchover-reversing-valve-6-ton-5-8-odf-x-7-8-idf-includes-solenoid-coil","title":"Trane \/ American Standard VAL08884 OEM Switchover Reversing Valve – 6 Ton, 5\/8\" ODF x 7\/8\" IDF, Includes Solenoid Coil","description":"\u003cp class=\"MsoNormal\"\u003eThe Trane \/ American Standard VAL08884 is an OEM 6-ton switchover reversing valve designed for compatible HVAC heat pump systems. Featuring 5\/8-inch ODF x 7\/8-inch IDF connections, this valve includes the solenoid coil required for its changeover operation.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe VAL08884 reversing valve controls refrigerant flow direction, allowing compatible heat pump systems to switch between heating and cooling modes. Its operation supports proper refrigerant circulation and reliable heating and cooling performance.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis factory replacement component is intended for HVAC equipment specifically requiring Trane part number VAL08884.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features \u0026amp; Function\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eGenuine Trane \/ American Standard OEM replacement component\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003ePart Number: VAL08884\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e6-ton nominal capacity\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e5\/8\" ODF connection\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e7\/8\" IDF connection\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eIncludes solenoid coil\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eSwitchover \/ reversing valve assembly\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eControls refrigerant flow direction\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eEnables heat pump heating and cooling changeover\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for compatible heat pump refrigeration circuits\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eFactory replacement HVAC component\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Details \u0026amp; Key Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eBrand\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eTrane \/ American Standard\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eManufacturer Part Number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVAL08884\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eProduct Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eSwitchover \/ Reversing Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eCommon Name\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHeat Pump Reversing Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eNominal Capacity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e6 Ton\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eNominal Capacity Class\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e72,000 BTU\/hr\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eConnection 1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e5\/8\" ODF\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eConnection 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e7\/8\" IDF\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eConnection Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eSweat \/ Brazed Refrigerant Connections\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eSolenoid Coil\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eIncluded\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003ePrimary Function\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eRefrigerant Flow Reversal\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 12;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eApplication\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHeat Pump Heating and Cooling\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 13;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eReplacement Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eOEM Service Component\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 14;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eSolenoid Voltage\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify manufacturer specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 15;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eRefrigerant Compatibility\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify equipment specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 16;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eWire Harness\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify included components\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 17; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eInstallation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eProfessional HVAC Installation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Segoe UI Emoji',sans-serif; mso-bidi-font-family: 'Segoe UI Emoji';\"\u003e🛠️\u003c\/span\u003e HVAC Depot Pro Tip\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWhen replacing the Trane VAL08884, verify the original valve configuration and refrigerant connections before ordering.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003ePart Number: VAL08884\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eNominal Capacity: 6 Ton\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eConnection Sizes: 5\/8\" ODF x 7\/8\" IDF\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eSolenoid Coil: Included\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eODF and IDF describe different connection dimensions. Confirm the actual tubing fit and connection orientation before installation.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eA reversing valve must match more than the system tonnage. Verify the equipment model, refrigerant type, solenoid voltage, valve configuration, and manufacturer-approved application.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eProfessional installation is required. Replacement involves refrigerant recovery, brazing, evacuation, leak testing, and verification of heating and cooling operation.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment \/ Model Compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Trane \/ American Standard VAL08884 is intended for compatible heat pump equipment specifically requiring this factory 6-ton switchover valve assembly.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003ePotential applications include:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eCompatible Trane heat pump systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eCompatible American Standard heat pump systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eSelect HVAC refrigeration systems requiring VAL08884\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eEquipment designed for the specified 5\/8\" ODF x 7\/8\" IDF valve connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eBefore ordering, confirm the complete equipment model number, serial number, original reversing valve part number, refrigerant type, and solenoid coil requirements.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eCompatibility Note: Exact equipment model numbers, refrigerant compatibility, and solenoid voltage have not been independently confirmed.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Trane \/ American Standard","offers":[{"title":"Default Title","offer_id":54016466846059,"sku":"VAL08884","price":245.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/VAL08884.jpg?v=1791478694"},{"product_id":"trane-american-standard-val08612-oem-thermostatic-expansion-valve-txv-4-ton-hvac-refrigerant-metering-valve","title":"Trane \/ American Standard VAL08612 OEM Thermostatic Expansion Valve (TXV) – 4 Ton HVAC Refrigerant Metering Valve","description":"\u003cp\u003eThe \u003cspan\u003eTrane \/ American Standard VAL08612\u003c\/span\u003e is an OEM \u003cspan\u003e4-ton thermostatic expansion valve (TXV)\u003c\/span\u003e designed for compatible HVAC air-conditioning and refrigeration systems. This valve regulates refrigerant flow entering the evaporator coil, helping maintain proper cooling performance and refrigerant distribution.\u003c\/p\u003e\n\u003cp\u003eThe \u003cspan\u003eVAL08612 TXV\u003c\/span\u003e responds to changing evaporator operating conditions to help maintain appropriate refrigerant superheat. Proper refrigerant metering supports efficient heat transfer, consistent cooling performance, and compressor protection.\u003c\/p\u003e\n\u003cp\u003eThis factory replacement expansion valve is intended for compatible HVAC equipment specifically requiring \u003cspan\u003eTrane part number VAL08612\u003c\/span\u003e.\u003c\/p\u003e\n\u003ch2\u003eKey Features \u0026amp; Function\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eGenuine \u003cspan\u003eTrane \/ American Standard OEM\u003c\/span\u003e replacement component\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003ePart Number: VAL08612\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eThermostatic Expansion Valve (\u003cspan\u003eTXV\u003c\/span\u003e)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e4-ton nominal capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e48,000 BTU\/hr nominal system capacity class\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eRegulates refrigerant entering the evaporator coil\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eHelps maintain proper evaporator superheat\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eSupports efficient air-conditioning operation\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eRefrigerant metering component\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eDesigned for compatible HVAC refrigeration applications\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eFactory replacement expansion valve\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Details \u0026amp; Key Specifications\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eSpecification\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDetails\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTrane \/ American Standard\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eManufacturer Part Number\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eVAL08612\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eThermostatic Expansion Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eCommon Name\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTXV \/ Expansion Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eNominal Capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e4 Ton\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eNominal System Capacity Class\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e48,000 BTU\/hr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003ePrimary Function\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRefrigerant Metering\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eApplication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eHVAC Evaporator \/ Refrigeration Circuit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eReplacement Type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOEM Service Component\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eRefrigerant Type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eVerify manufacturer specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eInlet Connection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eVerify manufacturer specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eOutlet Connection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eVerify manufacturer specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eEqualizer Configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eVerify manufacturer specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eValve Configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eVerify original equipment requirements\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eInstallation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eProfessional HVAC Installation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e🛠️ HVAC Depot Pro Tip\u003c\/h2\u003e\n\u003cp\u003eWhen replacing the \u003cspan\u003eTrane VAL08612\u003c\/span\u003e, verify the exact factory part number before ordering.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePart Number: \u003ccode\u003eVAL08612\u003c\/code\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eNominal Capacity: 4 Ton\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eComponent: Thermostatic Expansion Valve (TXV)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eNot all 4-ton expansion valves are interchangeable. Even when two TXVs have the same nominal capacity, they may differ in refrigerant compatibility, connection dimensions, equalizer configuration, and operating characteristics.\u003c\/p\u003e\n\u003cp\u003eBefore purchasing, confirm the equipment model, original valve number, refrigerant type, and inlet\/outlet connections.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eInstallation Tip:\u003c\/span\u003e A qualified HVAC technician should follow proper refrigerant recovery, brazing, evacuation, leak-testing, charging, and superheat verification procedures.\u003c\/p\u003e\n\u003ch2\u003eEquipment \/ Model Compatibility\u003c\/h2\u003e\n\u003cp\u003eThe \u003cspan\u003eTrane \/ American Standard VAL08612\u003c\/span\u003e is intended for compatible HVAC equipment specifically requiring this factory \u003cspan\u003e4-ton thermostatic expansion valve\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003ePotential applications include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eCompatible Trane evaporator coil assemblies\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eCompatible American Standard evaporator coil assemblies\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eSelect 4-ton air-conditioning systems\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eSelect heat-pump systems where specified by the manufacturer\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eHVAC equipment requiring \u003cspan\u003eVAL08612\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBefore ordering, verify the complete indoor and outdoor equipment model numbers, serial numbers, refrigerant type, original TXV part number, and connection configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCompatibility Note:\u003c\/span\u003e Specific equipment model numbers, refrigerant ratings, and connection dimensions have not been independently confirmed for VAL08612.\u003c\/p\u003e","brand":"Trane","offers":[{"title":"Default Title","offer_id":54016485327211,"sku":"VAL08612","price":225.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/VAL08612.jpg?v=1791479111"},{"product_id":"trane-american-standard-val10196-oem-electronic-expansion-valve-eev-hvac-refrigerant-flow-control-valve","title":"Trane \/ American Standard VAL10196 OEM Electronic Expansion Valve (EEV) – HVAC Refrigerant Flow Control Valve","description":"\u003cp class=\"MsoNormal\"\u003eThe Trane \/ American Standard VAL10196 is an OEM Electronic Expansion Valve (EEV) designed for compatible HVAC air-conditioning and heat pump systems. This electronic refrigerant metering valve regulates refrigerant flow through the refrigeration circuit to support proper cooling and heating performance.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eUnlike a traditional thermostatic expansion valve (TXV), an electronic expansion valve operates through signals from a compatible electronic control system. The EEV adjusts refrigerant flow based on system operating conditions, helping maintain appropriate evaporator performance, refrigerant control, and overall system efficiency.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe VAL10196 is intended for HVAC equipment specifically requiring this factory electronic expansion valve.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features \u0026amp; Function\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eGenuine Trane \/ American Standard OEM replacement component\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003ePart Number: VAL10196\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eElectronic Expansion Valve (EEV)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eElectronically controlled refrigerant metering\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eRegulates refrigerant flow through compatible HVAC systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eWorks with equipment-specific electronic controls\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eSupports evaporator performance and refrigerant management\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for compatible air-conditioning and heat pump applications\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eFactory replacement refrigeration component\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eIntended for equipment specifically requiring VAL10196\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Details \u0026amp; Key Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eBrand\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eTrane \/ American Standard\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eManufacturer Part Number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVAL10196\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eProduct Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eElectronic Expansion Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eCommon Name\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eEEV \/ Electronic Refrigerant Metering Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eValve Operation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eElectronically Controlled\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003ePrimary Function\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eRefrigerant Flow Regulation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eApplication\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHVAC Refrigeration Circuit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eReplacement Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eOEM Service Component\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eNominal Capacity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify manufacturer specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eRefrigerant Compatibility\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify manufacturer specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eInlet Connection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify manufacturer specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 12;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eOutlet Connection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify manufacturer specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 13;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eElectrical Requirements\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify manufacturer specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 14;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eControl Compatibility\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eEquipment-Specific\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 15;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eActuator \/ Coil Inclusion\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify supplied assembly\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 16;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eWire Harness Inclusion\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify supplied assembly\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 17; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eInstallation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eProfessional HVAC Installation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Segoe UI Emoji',sans-serif; mso-bidi-font-family: 'Segoe UI Emoji';\"\u003e🛠️\u003c\/span\u003e HVAC Depot Pro Tip\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWhen replacing the Trane VAL10196, verify the complete OEM part number and equipment compatibility before ordering.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003ePart Number: VAL10196\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eComponent: Electronic Expansion Valve (EEV)\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFunction: Electronic Refrigerant Metering\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eAn electronic expansion valve is not interchangeable with a conventional TXV simply because the connection sizes or refrigeration capacity appear similar.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBefore purchasing, confirm:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eOriginal EEV part number\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eComplete equipment model and serial number\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eRefrigerant type\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eInlet and outlet connection sizes\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eElectronic control board compatibility\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eActuator or coil requirements\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eElectrical connector and wiring configuration\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eManufacturer-specific installation or calibration procedures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eInstallation Tip: EEV replacement may require refrigerant recovery, brazing, evacuation, leak testing, electrical verification, and electronic valve initialization or calibration, depending on the equipment.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eInstallation should be performed by a qualified HVAC technician.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment \/ Model Compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Trane \/ American Standard VAL10196 is intended for compatible HVAC equipment specifically requiring this factory electronic expansion valve.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003ePotential applications include:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eCompatible Trane air-conditioning systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eCompatible Trane heat pump systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eCompatible American Standard HVAC equipment\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eSelect electronically controlled refrigeration systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eEquipment requiring OEM part number VAL10196\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eBefore ordering, verify the complete equipment model number, serial number, original EEV identification, refrigerant type, and electronic control requirements.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eCompatibility Note: Exact equipment model numbers, refrigerant compatibility, valve capacity, and connection dimensions have not been independently confirmed for VAL10196.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Trane \/ American Standard","offers":[{"title":"Default Title","offer_id":54016632258923,"sku":"VAL10196","price":158.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/VAL10196.jpg?v=1791483642"},{"product_id":"trane-american-standard-val09554-oem-thermostatic-expansion-valve-txv-2-ton-hvac-refrigerant-metering-valve","title":"Trane \/ American Standard VAL09554 OEM Thermostatic Expansion Valve (TXV) – 2 Ton HVAC Refrigerant Metering Valve","description":"\u003cp class=\"MsoNormal\"\u003eThe Trane \/ American Standard VAL09554 is an OEM 2-ton thermostatic expansion valve (TXV) designed for compatible HVAC air-conditioning and refrigeration systems. This valve regulates refrigerant flow entering the evaporator coil, helping maintain proper cooling performance and efficient system operation.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe VAL09554 TXV responds to changing evaporator operating conditions to regulate refrigerant flow and maintain appropriate superheat. Proper refrigerant metering helps support efficient heat transfer, consistent cooling, and compressor protection.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis factory replacement expansion valve is intended for HVAC equipment specifically requiring Trane part number VAL09554.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features \u0026amp; Function\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eGenuine Trane \/ American Standard OEM replacement component\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003ePart Number: VAL09554\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eThermostatic Expansion Valve (TXV)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e2-ton nominal capacity\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e24,000 BTU\/hr nominal system capacity class\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eRegulates refrigerant entering the evaporator coil\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eHelps maintain proper evaporator superheat\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eSupports efficient air-conditioning performance\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eRefrigerant metering component\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for compatible HVAC refrigeration applications\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eFactory replacement expansion valve\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Details \u0026amp; Key Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eBrand\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eTrane \/ American Standard\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eManufacturer Part Number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVAL09554\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eProduct Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eThermostatic Expansion Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eCommon Name\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eTXV \/ Expansion Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eNominal Capacity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e2 Ton\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eNominal System Capacity Class\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e24,000 BTU\/hr\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003ePrimary Function\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eRefrigerant Metering\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eApplication\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHVAC Evaporator \/ Refrigeration Circuit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eReplacement Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eOEM Service Component\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eRefrigerant Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify manufacturer specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eInlet Connection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify manufacturer specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 12;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eOutlet Connection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify manufacturer specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 13;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eEqualizer Configuration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify manufacturer specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 14;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eValve Configuration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify original equipment requirements\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 15; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eInstallation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eProfessional HVAC Installation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Segoe UI Emoji',sans-serif; mso-bidi-font-family: 'Segoe UI Emoji';\"\u003e🛠️\u003c\/span\u003e HVAC Depot Pro Tip\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWhen replacing the Trane VAL09554, verify the exact OEM part number and valve specifications before ordering.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003ePart Number: VAL09554\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eNominal Capacity: 2 Ton\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eComponent: Thermostatic Expansion Valve (TXV)\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eNot all 2-ton TXVs are interchangeable. Valves with the same nominal capacity may differ in refrigerant compatibility, connection dimensions, equalizer configuration, and operating characteristics.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBefore purchasing, confirm the equipment model number, original valve identification, refrigerant type, and inlet\/outlet connections.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eInstallation Tip: A qualified HVAC technician should follow proper refrigerant recovery, brazing, evacuation, leak testing, charging, and superheat verification procedures.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment \/ Model Compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Trane \/ American Standard VAL09554 is intended for compatible HVAC equipment specifically requiring this factory 2-ton thermostatic expansion valve.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003ePotential applications include:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eCompatible Trane evaporator coil assemblies\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eCompatible American Standard evaporator coil assemblies\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eSelect 2-ton air-conditioning systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eSelect heat-pump systems where specified by the manufacturer\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eHVAC equipment requiring VAL09554\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eBefore ordering, verify the complete indoor and outdoor equipment model numbers, serial numbers, refrigerant type, original TXV part number, and connection configuration.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eCompatibility Note: Specific equipment model numbers, refrigerant ratings, and connection dimensions have not been independently confirmed for VAL09554.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Trane \/ American Standard","offers":[{"title":"Default Title","offer_id":54016656769387,"sku":"VAL09554","price":220.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/VAL09554.jpg?v=1791484194"},{"product_id":"trane-american-standard-val11539-oem-thermostatic-expansion-valve-txv-hvac-refrigerant-metering-valve-4ton-410a","title":"Trane \/ American Standard VAL11539 OEM Thermostatic Expansion Valve (TXV) – HVAC Refrigerant Metering Valve 4Ton 410A","description":"\u003cp class=\"MsoNormal\"\u003eThe Trane \/ American Standard VAL11539 is an OEM thermostatic expansion valve (TXV) designed for compatible HVAC air-conditioning and refrigeration equipment. This valve regulates refrigerant flow entering the evaporator coil, helping maintain proper cooling performance and efficient system operation.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe VAL11539 TXV automatically adjusts refrigerant flow in response to evaporator operating conditions. By helping maintain appropriate refrigerant superheat, this expansion valve supports efficient heat transfer, reliable cooling performance, and compressor protection.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis factory replacement valve is intended for equipment specifically requiring Trane part number VAL11539.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features \u0026amp; Function\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eGenuine Trane \/ American Standard OEM replacement component\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003ePart Number: VAL11539\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eThermostatic Expansion Valve (TXV)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eRegulates refrigerant flow into the evaporator coil\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eHelps maintain appropriate evaporator superheat\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eSupports consistent air-conditioning performance\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eThermostatically controlled refrigerant metering\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for compatible HVAC refrigeration systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eEquipment-specific factory replacement component\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Details \u0026amp; Key Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eBrand\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eTrane \/ American Standard\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eManufacturer Part Number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVAL11539\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eProduct Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eThermostatic Expansion Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eCommon Name\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eTXV \/ Thermal Expansion Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003ePrimary Function\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eRefrigerant Flow Regulation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eValve Operation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eThermostatic\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eApplication\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHVAC Evaporator \/ Refrigeration Circuit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eReplacement Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eOEM Service Component\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eNominal Capacity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eNot verified\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eRefrigerant Compatibility\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eNot verified\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eInlet Connection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eNot verified\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 12;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eOutlet Connection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eNot verified\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 13;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eEqualizer Configuration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eNot verified\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 14; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eInstallation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eQualified HVAC Technician Required\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Segoe UI Emoji',sans-serif; mso-bidi-font-family: 'Segoe UI Emoji';\"\u003e🛠️\u003c\/span\u003e HVAC Depot Pro Tip\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBefore replacing the Trane VAL11539, confirm the original equipment specifications.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003ePart Number: VAL11539\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eComponent: Thermostatic Expansion Valve (TXV)\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eNot all thermostatic expansion valves are interchangeable. Even valves with similar physical dimensions may have different refrigerant ratings, capacity ranges, inlet\/outlet connections, and equalizer configurations.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eAlways verify the exact OEM part number, refrigerant type, equipment model, and valve configuration before ordering.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eInstallation Tip: TXV replacement requires proper refrigerant recovery, brazing precautions, evacuation, leak testing, system charging, and superheat verification by a qualified HVAC technician.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment \/ Model Compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Trane \/ American Standard VAL11539 is intended for compatible HVAC equipment specifically requiring this OEM expansion valve.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eApplications may include compatible Trane and American Standard evaporator coil assemblies and refrigeration systems where VAL11539 is specified by the manufacturer.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBefore ordering, verify the complete equipment model number, serial number, original TXV identification, and refrigerant requirements.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eCompatibility Note: Exact equipment model numbers, tonnage, refrigerant compatibility, and connection sizes have not been independently confirmed.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Trane","offers":[{"title":"Default Title","offer_id":54019876913515,"sku":"VAL11539","price":209.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/VAL11539.jpg?v=1791558029"},{"product_id":"trane-american-standard-val09228-oem-thermostatic-expansion-valve-txv-3-ton-hvac-refrigerant-metering-valve","title":"Trane \/ American Standard VAL09228 OEM Thermostatic Expansion Valve (TXV) – 3 Ton HVAC Refrigerant Metering Valve","description":"\u003cp class=\"MsoNormal\"\u003eThe Trane \/ American Standard VAL09228 is an OEM 3-ton thermostatic expansion valve (TXV) designed for compatible HVAC air-conditioning and refrigeration systems. This valve regulates refrigerant flow entering the evaporator coil, helping maintain proper cooling performance and efficient system operation.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe VAL09228 TXV automatically adjusts refrigerant flow in response to evaporator operating conditions. By helping maintain appropriate refrigerant superheat, this expansion valve supports efficient heat transfer, consistent cooling performance, and compressor protection.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis factory replacement expansion valve is intended for HVAC equipment specifically requiring Trane part number VAL09228.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features \u0026amp; Function\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eGenuine Trane \/ American Standard OEM replacement component\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003ePart Number: VAL09228\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eThermostatic Expansion Valve (TXV)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e3-ton nominal capacity\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e36,000 BTU\/hr nominal system capacity class\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eRegulates refrigerant entering the evaporator coil\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eHelps maintain appropriate evaporator superheat\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eSupports efficient air-conditioning performance\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eThermostatically controlled refrigerant metering\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for compatible HVAC refrigeration applications\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eFactory replacement expansion valve\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Details \u0026amp; Key Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eBrand\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eTrane \/ American Standard\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eManufacturer Part Number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVAL09228\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eProduct Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eThermostatic Expansion Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eCommon Name\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eTXV \/ Thermal Expansion Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eNominal Capacity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e3 Ton\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eNominal System Capacity Class\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e36,000 BTU\/hr\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003ePrimary Function\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eRefrigerant Metering\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eValve Operation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eThermostatic\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eApplication\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHVAC Evaporator \/ Refrigeration Circuit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eReplacement Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eOEM Service Component\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eRefrigerant Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify manufacturer specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 12;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eInlet Connection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify manufacturer specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 13;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eOutlet Connection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify manufacturer specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 14;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eEqualizer Configuration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify manufacturer specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 15;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eValve Configuration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify original equipment requirements\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 16; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eInstallation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eProfessional HVAC Installation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Segoe UI Emoji',sans-serif; mso-bidi-font-family: 'Segoe UI Emoji';\"\u003e🛠️\u003c\/span\u003e HVAC Depot Pro Tip\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWhen replacing the Trane VAL09228, verify the exact factory part number and valve configuration before ordering.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003ePart Number: VAL09228\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eNominal Capacity: 3 Ton\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eComponent: Thermostatic Expansion Valve (TXV)\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eNot all 3-ton expansion valves are interchangeable. Even when two valves have the same nominal capacity, they may differ in refrigerant compatibility, inlet and outlet connection sizes, equalizer configuration, and operating characteristics.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBefore purchasing, confirm the original TXV identification, complete equipment model number, refrigerant type, and connection dimensions.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eInstallation Tip: TXV replacement requires proper refrigerant recovery, brazing precautions, evacuation, leak testing, charging, and superheat verification by a qualified HVAC technician.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment \/ Model Compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Trane \/ American Standard VAL09228 is intended for compatible HVAC equipment specifically requiring this factory 3-ton thermostatic expansion valve.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003ePotential applications include:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eCompatible Trane evaporator coil assemblies\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eCompatible American Standard evaporator coil assemblies\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eSelect 3-ton air-conditioning systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eSelect heat-pump systems where specified by the manufacturer\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eHVAC equipment requiring VAL09228\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eBefore ordering, verify the complete indoor and outdoor equipment model numbers, serial numbers, refrigerant type, original TXV part number, and connection configuration.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eCompatibility Note: Specific equipment model numbers, refrigerant ratings, and connection dimensions have not been independently confirmed for VAL09228.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Trane \/ American Standard","offers":[{"title":"Default Title","offer_id":54019901686123,"sku":"VAL09228","price":219.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/VAL09228.jpg?v=1791558919"}],"url":"https:\/\/tophvacparts.com\/collections\/txv.oembed?page=3","provider":"HVAC Parts and Equipment Depot Open To Homeowners and Contractors","version":"1.0","type":"link"}