{"title":"Lennox Furnace Gas Valves | OEM Gas Valve Replacement Parts","description":"","products":[{"product_id":"lennox-36j22-214-electronic-ignition-gas-valve-1-stage-fast-opening","title":"Lennox 36J22-214 Electronic Ignition Gas Valve, 1 - Stage Fast Opening","description":"\u003ch1\u003e\u003cstrong\u003eWhite-Rodgers 36J22-214 – Single-Stage Fast Opening Electronic Ignition Gas Valve \u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eWhite-Rodgers 36J22-214\u003c\/strong\u003e is a high-\u003cstrong\u003eperformance,\u003c\/strong\u003e \u003cstrong\u003esingle-stage \u003c\/strong\u003eelectronic \u003cstrong\u003eignition \u003c\/strong\u003egas valve designed to \u003cstrong\u003ereplace \u003c\/strong\u003ehundreds of existing models in the field. This robust component ensures safe and efficient gas control for non-piloted intermittent ignition systems, such as Hot Surface Ignition (HSI) and Direct Spark Ignition (DSI). Its \"fast opening\" characteristic provides a quick, reliable ignition sequence for heating systems in a compact footprint. \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThis valve is engineered by \u003cstrong\u003eWhite-Rodgers\/Emerson\u003c\/strong\u003e, a leader in HVAC components, ensuring high quality and reliability. It is designed to be highly versatile, compatible with both natural gas and liquid propane (\u003cstrong\u003eLP\u003c\/strong\u003e) systems, with the necessary LP conversion kit included in the package. This makes it a go-to universal replacement part for service technicians. \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features and Function:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast Opening:\u003c\/strong\u003e Ensures rapid and efficient gas flow upon ignition, minimizing start-up time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal Compatibility:\u003c\/strong\u003e Designed to replace hundreds of single-stage gas valves used across various residential and commercial applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel Ready:\u003c\/strong\u003e Convertible for use with either natural gas or LP, with an LP conversion kit included.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Assurance:\u003c\/strong\u003e Features a reliable dual-safety shutoff design to immediately cut off gas flow if an unsafe condition is detected. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Details and Key Specifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e White-Rodgers \/ Emerson\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e 36J22-214\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Type:\u003c\/strong\u003e Single-Stage Combination Gas Control Valve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Type:\u003c\/strong\u003e Natural Gas or LP (Convertible)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 VAC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInlet \/ Outlet Size:\u003c\/strong\u003e 1\/2\" NPT (Reducer bushings to 3\/8\" included)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacity (NG): \u003c\/strong\u003e140,000 BTUh nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacity (LP):\u003c\/strong\u003e 226,800 BTUh nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegulator Setting (NG):\u003c\/strong\u003e 3.5\" W.C. (adjustable range 2.5\"-5.0\")\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Pressure:\u003c\/strong\u003e 1\/2 PSI (14.0\" W.C.) \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGross Shipping Weight: \u003c\/strong\u003e 2.5 LB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e🛠️ HVAC Depot Pro Tip: The Universal Solution\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThis valve is highly versatile. Its ability to mount in any position, including upside down, combined with the included LP conversion kit and reducer bushings, makes it one of the most flexible parts a technician can carry on their truck, often preventing a second trip to the job site. \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eThe 36J22-214 is a direct replacement for the following part numbers:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eWhite-Rodgers:\u003c\/strong\u003e\u003c\/h3\u003e\n36J22-214, 36G22-214, 36G22-502, 36E22-214.\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eCross-Refs:\u003c\/strong\u003e\u003c\/h3\u003e\nReplaces various OEM numbers from Goodman, York, Carrier, Trane, and others who use the 36J Series form factor. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eExtensive Model Compatibility List:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eNote: This is a universal replacement part. Use the cross-reference table provided with the valve or the manufacturer's mobile app to verify compatibility with specific furnace models. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eGoodman:\u003c\/strong\u003e\u003c\/h3\u003e\nCompatible with specific Goodman gas furnace models that utilize a single-stage, fast-opening valve.\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eYork\/Luxaire: \u003c\/strong\u003e\u003c\/h3\u003e\nReplaces many older York\/Luxaire single-stage valves (e.g., 025-38979-000).\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eUniversal Applications:\u003c\/strong\u003e\u003c\/h3\u003e\nSuitable for use in a wide range of industrial processes, heating systems, and other combustion equipment\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lennox","offers":[{"title":"Default Title","offer_id":52237872562539,"sku":"36J22-214","price":182.22,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/36J22.jpg?v=1772828468"},{"product_id":"lennox-36j55-214-electronic-ignition-gas-valve-2-stage-slow-opening","title":"White-Rodgers 36J55-214 – 2-Stage Slow Opening Electronic Ignition Gas Valve","description":"\u003ch1\u003e\u003cstrong\u003eWhite-Rodgers 36J55-214 – 2-Stage Slow Opening Electronic Ignition Gas Valve\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eWhite-Rodgers 36J55-214\u003c\/strong\u003e is a high-performance \u003cstrong\u003e2-Stage\u003c\/strong\u003e Electronic Ignition \u003cstrong\u003eGas Valve\u003c\/strong\u003e. This robust component is a versatile universal replacement and \u003cstrong\u003eOEM \u003c\/strong\u003epart used across many furnace brands. It is engineered to safely regulate natural gas flow in \u003cstrong\u003etwo \u003c\/strong\u003eprecise \u003cstrong\u003estages \u003c\/strong\u003e(\u003cstrong\u003elow and high fire\u003c\/strong\u003e), providing superior comfort control, enhanced fuel efficiency, and a quieter start-up compared to standard single-stage valves.\u003c\/p\u003e\n\u003cp\u003eThis valve features a \u003cstrong\u003eslow opening mechanism\u003c\/strong\u003e on both the \u003cstrong\u003elow \u003c\/strong\u003eand \u003cstrong\u003ehigh \u003c\/strong\u003estages. This design ensures a smooth, quiet ignition sequence, minimizing loud \"rumbling\" or \"whooshing\" sounds often heard when gas is introduced too quickly. It is designed for dual-direct ignition systems (\u003cstrong\u003ehot surface or direct spark\u003c\/strong\u003e) and operates on a standard \u003cstrong\u003e24 VAC \u003c\/strong\u003eelectrical signal.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features and Function:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo-Stage Operation: \u003c\/strong\u003eDelivers variable heat output for enhanced comfort and fuel savings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlow Opening Design:\u003c\/strong\u003e Ensures a smooth, quiet, and reliable ignition sequence, reducing noise and ignition shock.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Compatibility:\u003c\/strong\u003e A common replacement model used in various residential and light commercial furnaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Assurance:\u003c\/strong\u003e Features a dual safety shutoff design that immediately cuts off gas flow if a flame signal is lost or other safety interlocks are triggered.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Details and Key Specifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e White-Rodgers \/ Emerson\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e 36J55-214\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Type:\u003c\/strong\u003e 2-Stage Combination Gas Control Valve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Type:\u003c\/strong\u003e Natural Gas (NG) (LP Conversion Kit typically sold separately)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 VAC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInlet \/ Outlet Size:\u003c\/strong\u003e 1\/2\" NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacity: \u003c\/strong\u003e150,000 BTUh (Max nominal)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpening Characteristic:\u003c\/strong\u003e Slow Opening (Both stages)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Pressure:\u003c\/strong\u003e 1\/2 PSI\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnition Type:\u003c\/strong\u003e Dual Direct Ignition (HSI\/DSI)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e🛠️ HVAC Depot Pro Tip: Understanding \"Slow Opening\"\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \"slow opening\" feature on the 36J55-214 is designed to prevent explosive ignition. This means the valve takes a moment longer to fully open the gas port after the igniter is hot. If you're replacing an old, fast-opening valve with this one, ensure your furnace control board's ignition timing sequence allows enough time for full ignition before locking out for a failed flame sense.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eThe 36J55-214 is a direct replacement for the following part numbers:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eWhite-Rodgers:\u003c\/strong\u003e\u003c\/h3\u003e\n36J55-214, 36J55-214P1, 36J55-201.\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eCross-Refs:\u003c\/strong\u003e\u003c\/h3\u003e\nA standard replacement for many OEM numbers from Carrier, Goodman, Trane, and others who use this form factor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eExtensive Model Compatibility List:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eNote: This is a universal\/aftermarket replacement part compatible with many brands and models. Use 'CTRL+F' to search for your specific model:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eUniversal Aftermarket Replacement: \u003c\/strong\u003e\u003c\/h3\u003e\nUsed in a wide range of furnace models from various manufacturers that require a 24V, 2-stage, 1\/2\" NPT gas valve with slow-opening characteristics.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lennox","offers":[{"title":"Default Title","offer_id":52237874889067,"sku":"36J55-214","price":245.39,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/6.webp?v=1753955307"},{"product_id":"lennox-103181-02-white-rodgers-36j55-255-natural-gas-2-stage-gas-valve","title":"Lennox P\/N 103181-01 (77W04) – White-Rodgers 36J55-254P1 2-Stage Natural Gas Valve","description":"\u003ch1\u003e\u003cstrong\u003eLennox P\/N 103181-01 (77W04) – White-Rodgers 36J55-254P1 2-Stage Natural Gas Valve\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eLennox 103181-01\u003c\/strong\u003e (Catalog \u003cstrong\u003e77W04\u003c\/strong\u003e) is a genuine \u003cstrong\u003eOEM White-Rodgers 36J55-254P1 2-Stage Gas Valve\u003c\/strong\u003e. This high-performance component is the primary fuel regulator for high-efficiency Lennox furnaces, specifically designed to handle two-stage heating cycles. By alternating between High and Low fire modes, it allows your furnace to provide consistent, whisper-quiet warmth while maximizing fuel economy and reducing temperature swings throughout your home.\u003c\/p\u003e\n\u003cp\u003eAs a Genuine \u003cstrong\u003eOEM \u003c\/strong\u003epart manufactured by \u003cstrong\u003eWhite-Rodgers\/Emerson\u003c\/strong\u003e, this valve is precision-calibrated for \u003cstrong\u003eLennox Elite\u003c\/strong\u003e (\u003cstrong\u003eEL280\u003c\/strong\u003e) and \u003cstrong\u003eSignature \u003c\/strong\u003e(\u003cstrong\u003eSL280\u003c\/strong\u003e) series \u003cstrong\u003eunits\u003c\/strong\u003e. It features a \u003cstrong\u003efast\u003c\/strong\u003e-\u003cstrong\u003eopening\u003c\/strong\u003e, dual-direct ignition design that integrates seamlessly with your system’s control board and safety sensors. Choosing a genuine replacement ensures your unit maintains its factory-specified pressure ratings and safety certifications, preventing the combustion issues often caused by universal aftermarket valves.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features and Function:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo-Stage Precision: \u003c\/strong\u003eDelivers a 1.7\" W.C. Low Fire and 3.5\" W.C. High Fire for variable heat output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenuine OEM Reliability:\u003c\/strong\u003e Official Lennox replacement part ensures 100% electrical and mechanical compatibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Configuration:\u003c\/strong\u003e Includes a factory-installed 0.25\" straight plug for simplified installation in modern cabinets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Integration:\u003c\/strong\u003e Regulates gas pressure and provides an immediate shut-off response to control board safety signals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Details and Key Specifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 103181-01 (Catalog # 77W04)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer: \u003c\/strong\u003eWhite-Rodgers \/ Emerson (Lennox OEM)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e 36J55-254P1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Type: \u003c\/strong\u003eNatural Gas (NG)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 VAC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInlet \/ Outlet Size:\u003c\/strong\u003e 1\/2\" NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegulator Setting (Hi Fire):\u003c\/strong\u003e 3.5\" W.C. +\/- 0.3\" @ 80K Btu\/HR\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegulator Setting (Lo Fire):\u003c\/strong\u003e 1.7\" W.C. +\/- 0.3\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStraight Plug (0.25\"):\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Weight: \u003c\/strong\u003eApprox. 3.2 LB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e🛠️ HVAC Depot Pro Tip: Manometer Verification\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAfter installing the 103181-01, it is essential to use a digital manometer to verify the manifold pressure for both stages. While factory-set, local gas pressure and altitude can affect performance. Adjusting the valve to the exact specs on your furnace rating plate (typically 1.7\" for low and 3.5\" for high) ensures the cleanest combustion and prevents premature heat exchanger failure.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eThe 103181-01 is a direct OEM replacement for the following part numbers:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eOEM Numbers:\u003c\/strong\u003e\u003c\/h3\u003e\n103181-01, 77W04, 77W0401.\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eWhite-Rodgers:\u003c\/strong\u003e\u003c\/h3\u003e\n36J55-254P1.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eExtensive Model Compatibility List:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eNote: Use 'CTRL+F' to search for your specific model and revision number:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eLennox Elite EL280 Series: \u003c\/strong\u003e\u003c\/h3\u003e\nEL280DF070\/090\/110, EL280UH045\/070\/090\/110\/135 (Revisions 01-03).\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eLennox Signature SL280 Series: \u003c\/strong\u003e\u003c\/h3\u003e\nSL280DF070\/090\/110, SL280UH070\/090\/110\/135 (Revisions 02-09).\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eLennox Merit\/Legacy Series:\u003c\/strong\u003e\u003c\/h3\u003e\nG24-200A, G25MV, G27M, G29M, ML180UH (Revision 55-56).\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eLennox LRP16 Series: \u003c\/strong\u003e\u003c\/h3\u003e\nLRP16GE24\/36\/48\/60 Packaged Units (Revisions 01-02).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lennox","offers":[{"title":"Default Title","offer_id":52237876625771,"sku":"66255143126","price":205.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/4-1.webp?v=1753941413"},{"product_id":"lennox-103181-01-white-rodgers-36j55-254p1-natural-gas-2-stage-gas-valve","title":"Lennox 103181-01 White Rodgers 36J55-254P1 Natural Gas 2-Stage Gas Valve","description":"\u003ch1\u003e\u003cstrong\u003eLennox P\/N 103181-01 (77W04) – White-Rodgers 36J55-254P1 2-Stage Natural Gas Valve\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe Lennox\u003cstrong\u003e 103181-01\u003c\/strong\u003e (Catalog 77W04) is a genuine \u003cstrong\u003eOEM White-Rodgers 36J55-254P1 2-Stage Gas Valve\u003c\/strong\u003e. This high-performance component is the \u003cstrong\u003eprimary \u003c\/strong\u003efuel regulator for high-efficiency Lennox furnaces, specifically designed to handle \u003cstrong\u003etwo-stage heating cycles\u003c\/strong\u003e. By alternating between High and Low fire modes, it allows your furnace to provide consistent, whisper-quiet warmth while maximizing fuel economy and reducing temperature swings throughout your home. \u003c\/p\u003e\n\u003cp\u003eAs a Genuine \u003cstrong\u003eOEM\u003c\/strong\u003e part manufactured by \u003cstrong\u003eWhite-Rodgers\/Emerson\u003c\/strong\u003e, this valve is precision-calibrated for \u003cstrong\u003eLennox Elite (EL280) and Signature (SL280) series units\u003c\/strong\u003e. It features a fast-opening, dual-direct ignition design that integrates seamlessly with your system’s control board and safety sensors. Choosing a genuine replacement ensures your unit maintains its factory-specified pressure ratings and safety certifications, preventing the combustion issues often caused by universal aftermarket valves.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features and Function:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo-Stage Precision: \u003c\/strong\u003eDelivers a 1.7\" W.C. Low Fire and 3.5\" W.C. High Fire for variable heat output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenuine OEM Reliability: \u003c\/strong\u003eOfficial Lennox replacement part ensures 100% electrical and mechanical compatibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Configuration:\u003c\/strong\u003e Includes a factory-installed 0.25\" straight plug for simplified installation in modern cabinets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Integration: \u003c\/strong\u003eRegulates gas pressure and provides an immediate shut-off response to control board safety signals. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Details and Key Specifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 103181-01 (Catalog # 77W04)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e White-Rodgers \/ Emerson (Lennox OEM)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e 36J55-254P1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Type:\u003c\/strong\u003e Natural Gas (NG)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 VAC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInlet \/ Outlet Size:\u003c\/strong\u003e 1\/2\" NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegulator Setting (Hi Fire):\u003c\/strong\u003e 3.5\" W.C. +\/- 0.3\" @ 80K Btu\/HR\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegulator Setting (Lo Fire): \u003c\/strong\u003e1.7\" W.C. +\/- 0.3\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStraight Plug (0.25\"):\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e Approx. 2.8 lbs \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e🛠️ HVAC Depot Pro Tip: Manometer Verification\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAfter installing the 103181-01, it is essential to use a digital manometer to verify the manifold pressure for both stages. While factory-set, local gas pressure and altitude can affect performance. Adjusting the valve to the exact specs on your furnace rating plate (typically 1.7\" for low and 3.5\" for high) ensures the cleanest combustion and prevents premature heat exchanger failure.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eThe 103181-01 is a direct OEM replacement for the following part numbers:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eOEM Numbers: \u003c\/strong\u003e\u003c\/h3\u003e\n103181-01, 77W04, 77W0401.\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eWhite-Rodgers:\u003c\/strong\u003e\u003c\/h3\u003e\n36J55-254P1. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eExtensive Model Compatibility List:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eNote: Use 'CTRL+F' to search for your specific model and revision number:\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eLennox Elite EL280 Series:\u003c\/strong\u003e\u003c\/h3\u003e\nEL280DF070\/090\/110, EL280UH045\/070\/090\/110\/135 (Revisions 01-03).\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eLennox Signature SL280 Series:\u003c\/strong\u003e\u003c\/h3\u003e\nSL280DF070\/090\/110, SL280UH070\/090\/110\/135 (Revisions 02-09).\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eLennox Merit\/Legacy Series:\u003c\/strong\u003e\u003c\/h3\u003e\nG24-200A, G25MV, G27M, G29M, ML180UH (Revision 55-56).\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eLennox LRP16 Series: \u003c\/strong\u003e\u003c\/h3\u003e\nLRP16GE24\/36\/48\/60 Packaged Units (Revisions 01-02).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003c\/h2\u003e","brand":"Lennox","offers":[{"title":"Default Title","offer_id":52237879411051,"sku":"66255143126","price":260.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/77W04.jpg?v=1772730596"},{"product_id":"lennox-78l6001-honeywell-vr8305q-4153-natural-gas-valve-2-stage-dual-direct-ignition-24-vac-3-4-npt","title":"Lennox P\/N 78L6001 (78L60) – Honeywell VR8305Q-4153 2-Stage Natural Gas Valve","description":"\u003ch1\u003e\n\u003cstrong\u003eLennox P\/N 78L6001 (78L60) – Honeywell VR8305Q-4153 2-Stage Natural Gas Valve\u003c\/strong\u003e \u003c\/h1\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe Lennox \u003cstrong\u003e78L6001 (Catalog 78L60\u003c\/strong\u003e) is a genuine \u003cstrong\u003eOEM Honeywell VR8305Q-4153 2-Stage Gas Valve\u003c\/strong\u003e. This robust component serves as the precise gas control for a wide array of high-efficiency Lennox residential furnaces. It is engineered to safely regulate natural gas flow in two distinct stages \u003cstrong\u003e(low fire at 1.6\" W.C. and high fire at 3.7\" W.C.)\u003c\/strong\u003e. This two-stage operation ensures enhanced comfort, greater fuel efficiency, and precise heating control by optimizing heat output based on demand. \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eChoosing a Genuine \u003cstrong\u003eOEM replacement\u003c\/strong\u003e, manufactured by \u003cstrong\u003eHoneywell\/Resideo\u003c\/strong\u003e, is essential for safety and reliability. This valve is built to specific factory flow and pressure ratings, ensuring it integrates perfectly with your furnace's ignition control board and maintains all necessary safety certifications. Generic alternatives may compromise system efficiency and potentially create hazardous conditions. It is a dual-direct ignition valve, compatible with hot surface or direct spark ignition systems. \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features and Function:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo-Stage Operation: \u003c\/strong\u003eProvides both low (1.6\" W.C.) and high (3.7\" W.C.) fire settings for enhanced comfort and efficiency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenuine OEM Reliability:\u003c\/strong\u003e Trusted Honeywell build quality ensures quiet operation and long-term durability within Lennox systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Assurance: \u003c\/strong\u003eFeatures a dual safety shutoff design that immediately cuts off gas flow if a flame signal is lost or other safety interlocks are triggered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Installation:\u003c\/strong\u003e Can be mounted from 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Details and Key Specifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number (Lennox):\u003c\/strong\u003e 78L6001 (Catalog # 78L60)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer: \u003c\/strong\u003eHoneywell \/ Resideo (Lennox OEM)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHoneywell P\/N:\u003c\/strong\u003e VR8305Q-4153\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel Type:\u003c\/strong\u003e Natural Gas (NG) (Includes LP Conversion Kit)\u003c\/li\u003e\n\u003cli\u003eI\u003cstrong\u003enlet \/ Outlet Size:\u003c\/strong\u003e 3\/4\" NPT (Includes 3\/4\" to 1\/2\" Reducer Bushings)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 VAC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacity:\u003c\/strong\u003e 30,000 - 300,000 BTUh\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegulator Setting (NG Low\/High):\u003c\/strong\u003e 1.6\" W.C. low \/ 3.7\" W.C. high\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Pressure:\u003c\/strong\u003e 0.5 PSI\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnition Type:\u003c\/strong\u003e Dual Direct Ignition (Hot Surface\/Direct Spark) \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e🛠️ HVAC Depot Pro Tip: Always Check Manifold Pressure\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAfter installing the 78L6001, always use a digital manometer to verify and, if necessary, adjust the final manifold pressure for both the low and high stages to exactly match the specifications listed on your furnace's nameplate for optimal performance and safety. \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003eThe 78L6001 is a direct OEM replacement for the following part numbers\u003c\/strong\u003e: \u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eOEM Numbers:\u003c\/strong\u003e\u003c\/h3\u003e\n78L6001, 78L60, 78L61, 78L62, 78L63, 78L64.\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eHoneywell:\u003c\/strong\u003e\u003c\/h3\u003e\nVR8305Q-4153. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eExtensive Model Compatibility List:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eNote: Use 'CTRL+F' to search for your specific model:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eLennox G24 Series:\u003c\/strong\u003e\u003c\/h3\u003e\nG24M2, G24M3, G24M4, G24M5 (Various Revisions).\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eLennox G26 Series: \u003c\/strong\u003e\u003c\/h3\u003e\nG26Q2, G26Q3, G26Q4, G26Q5 (Various Revisions).\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eLennox G60 Series:\u003c\/strong\u003e\u003c\/h3\u003e\nG60UH, G60DF (Various older two-stage models).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eCompatible with many Lennox, Armstrong, and Ducane units requiring a 2-stage direct ignition valve.\u003c\/p\u003e","brand":"Lennox","offers":[{"title":"Default Title","offer_id":52237884653931,"sku":"66255121783","price":385.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/download-5.webp?v=1753941801"},{"product_id":"lennox-604888-22-natural-to-lp-propane-gas-conversion-kit-ml180uhv-gas-furnaces","title":"Lennox 604888-22, Natural to LP\/Propane Gas Conversion Kit, ML180UHV Gas Furnaces","description":"\u003ch1\u003e\u003cstrong\u003eLennox P\/N 604888-22 (Catalog 19D58) – Genuine OEM Natural to LP Gas Conversion Kit\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp\u003eThe\u003cstrong\u003e Lennox 604888-22 (Catalog 19D58)\u003c\/strong\u003e is a genuine \u003cstrong\u003eOEM Natural Gas to LP\/Propane Gas Conversion Kit.\u003c\/strong\u003e This kit is essential for converting compatible Lennox furnaces from using natural gas (NG) to liquid propane (LP) as the fuel source. It contains all the necessary components, such as specific orifices and labels, to safely and efficiently modify the gas train and ensure proper combustion and performance when using the new fuel type. \u003c\/p\u003e\n\u003cp\u003eBeing a Genuine \u003cstrong\u003eOEM \u003c\/strong\u003epart from Lennox is vital for safety and regulatory compliance. Modifying a gas furnace requires precision components engineered to specific flow and pressure ratings. This original kit guarantees that all safety standards and efficiency ratings are maintained for the specific models it is designed for, such as the ML180UHV series, which cannot be guaranteed with generic, non-certified parts. \u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features and Function:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel Type Conversion:\u003c\/strong\u003e Allows specific natural gas furnaces to operate safely and efficiently using LP (propane) gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenuine OEM Reliability: \u003c\/strong\u003eOfficial part from Lennox, ensuring precise fitment and validated functionality for compatible units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete Kit Solution:\u003c\/strong\u003e Includes all necessary burner orifices, labels, and fittings for a compliant conversion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Assurance:\u003c\/strong\u003e Ensures proper combustion characteristics (pressure and flow) are met for the new fuel source. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Details and Key Specifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 604888-22\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Lennox (Genuine OEM)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Type:\u003c\/strong\u003e Natural Gas to LP Conversion Kit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog Number:\u003c\/strong\u003e 19D58\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFor Use In Elevations:\u003c\/strong\u003e 0-7500 ft (typical for this type of kit).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGross Shipping Weight:\u003c\/strong\u003e 1.75 LB (approx.) \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e🛠️ HVAC Depot Pro Tip: Professional Installation Required\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eGas conversion is a safety-critical procedure that must be performed by a qualified, licensed HVAC technician or gas fitter. Incorrect installation, particularly regarding orifice size or gas pressure adjustment, can lead to serious safety hazards, including fire or carbon monoxide leaks. Always verify final manifold pressure with a manometer after installation. \u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eThe 604888-22 is a direct OEM replacement for the following part numbers:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eOEM Numbers:\u003c\/strong\u003e\u003c\/h3\u003e\n604888-22, 19D58, 19D5801.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eExtensive Model Compatibility List:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eNote: Use 'CTRL+F' to search for your specific model:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eLennox ML180UHV Series: \u003c\/strong\u003e\u003c\/h3\u003e\nDesigned specifically for use with various models in the ML180UHV series gas furnaces.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lennox","offers":[{"title":"Default Title","offer_id":52451505078635,"sku":"604888-22","price":215.33,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/19D58.jpg?v=1772830407"},{"product_id":"lennox-102837-01-93m80-13h41-r44987-001-honeywell-vr8215s1248-b-dual-direct-ignition-gas-valve-24-vac-1-2-x-1-2-73w17","title":"Lennox 73W17 OEM Furnace Gas Valve | 24V Natural Gas 1\/2\" Dual Direct Ignition","description":"\u003ch2\u003e\u003cstrong\u003eLennox P\/N 73W17 – Genuine OEM Single-Stage Gas Valve \u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eLennox 73W17\u003c\/strong\u003e (Catalog \u003cstrong\u003e73W17\u003c\/strong\u003e) is a genuine \u003cstrong\u003eOEM\u003c\/strong\u003e \u003cstrong\u003eSingle-Stage Gas Valve\u003c\/strong\u003e engineered for precise fuel control and safe operation in Lennox, Armstrong, and Allied heating systems. As a critical ignition component, this valve regulates natural gas flow to the burners, ensuring efficient combustion while providing a vital safety shutoff. It is designed for dual direct ignition systems (hot surface or direct spark) and serves as the primary regulator to maintain stable heat output. \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eChoosing a\u003cstrong\u003e Genuine Lennox Approved \u003c\/strong\u003ereplacement like the \u003cstrong\u003eHoneywell VR8215S1248\/B\u003c\/strong\u003e ensures perfect electrical and mechanical compatibility. Generic valves may not meet the exact pressure response times required by your furnace’s control board, potentially leading to ignition delays or safety lockouts. This OEM valve is factory-calibrated for natural gas but can be converted to LP with the appropriate manufacturer kit. \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features and Function:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecise Fuel Regulation:\u003c\/strong\u003e Factory-set to 3.5\" W.C. for optimal natural gas combustion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenuine OEM Reliability:\u003c\/strong\u003e Trusted Honeywell\/Resideo build quality provides quiet operation and long-term durability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Safety Shutoff:\u003c\/strong\u003e Meets rigorous safety codes with a solenoid-operated first valve and a diaphragm-operated second valve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal Mounting:\u003c\/strong\u003e Features an \"any direction\" mounting design for easier installation in tight furnace cabinets. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Details and Key Specifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number: \u003c\/strong\u003e73W17 (replaces 102837-01)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Honeywell \/ Resideo (Lennox Approved)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHoneywell P\/N:\u003c\/strong\u003e VR8215S1248\/B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel Type:\u003c\/strong\u003e Natural Gas (LP convertible)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInlet\/Outlet:\u003c\/strong\u003e 1\/2\" NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacity:\u003c\/strong\u003e 150,000 BTUh\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Rating:\u003c\/strong\u003e 0.50 PSI\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGross Shipping Weight:\u003c\/strong\u003e 2 LB \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e🛠️ HVAC Depot Pro Tip: The Soap Bubble Test\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAfter installing the 73W17, never skip the leak test. Apply a non-corrosive bubble solution to the 1\/2\" NPT inlet and outlet connections while the furnace is running. Even a tiny, slow-growing bubble indicates a leak that must be sealed. Always check manifold pressure with a manometer to ensure it matches the 3.5\" W.C. spec on your furnace rating plate for the safest, most efficient flame. \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eThe 73W17 replaces the following part numbers: \u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eOEM \u0026amp; Honeywell Numbers:\u003c\/strong\u003e\u003c\/h3\u003e\n93M80, 80M30, 60M16, 52M66, 55W98, 100365-01, 102837-01, VR8215S1248.\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eLennox\/Allied Cross-Refs:\u003c\/strong\u003e\u003c\/h3\u003e\n73W1701, 73J16, 73J1601, 103734-01. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eExtensive Model Compatibility List:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eNote: Use 'CTRL+F' to search for your specific model:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eLennox Residential: \u003c\/strong\u003e\u003c\/h3\u003e\nA80UH1D, A93UH1D, A95UH1D, 80G1UH135, ML193UH, 92G1UH045.\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eLennox Commercial\/Outdoor:\u003c\/strong\u003e\u003c\/h3\u003e\n13GCSXA-42, 13GCSXA-48 series packaged units. \u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lennox","offers":[{"title":"Default Title","offer_id":52645357781355,"sku":"66255141828","price":188.73,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/Gasvalve.jpg?v=1764800049"},{"product_id":"lennox-13h33-13h3301-oem-gas-valve-24-vac-1-2-npt-electronic-ignition-furnace-valve","title":"Lennox 13H33 \/ 13H3301 OEM Gas Valve – 24 VAC, 1\/2\" NPT, Electronic Ignition Furnace Valve","description":"\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eLennox 13H33\u003c\/b\u003e, model\/part \u003cb\u003e13H3301\u003c\/b\u003e, is a genuine OEM \u003cb\u003e24 VAC gas valve\u003c\/b\u003e designed for select Lennox gas-fired HVAC equipment with \u003cb\u003eelectronic ignition\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis valve uses \u003cb\u003e1\/2-inch NPT connections\u003c\/b\u003e and controls the flow of gas to the burner assembly in response to the furnace ignition control. It is intended as an OEM service replacement for compatible Lennox furnaces and heating equipment requiring the \u003cb\u003e13H3301\u003c\/b\u003e gas valve.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features \u0026amp; Function\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eGenuine \u003cb\u003eLennox OEM\u003c\/b\u003e component\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eCat #: 13H33\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eModel \/ Part #: 13H3301\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eFurnace gas valve\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003e24 VAC\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003e1\/2\" NPT\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for \u003cb\u003eelectronic ignition\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eControls gas flow to the burner assembly\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eElectrically operated furnace valve\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for compatible Lennox gas heating equipment\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eOEM service replacement component\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Details \u0026amp; Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eBrand\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eLennox\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCatalog Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e13H33\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eModel \/ Part Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e13H3301\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eGas Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eVoltage\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e24 VAC\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eConnection Size\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e1\/2\" NPT\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eIgnition Application\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eElectronic Ignition\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eApplication\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eGas Furnace \/ Heating Equipment\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eFunction\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eControls Gas Flow to Burner\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eOEM Component\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eManufacturer\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eLennox\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Segoe UI Emoji',sans-serif; mso-bidi-font-family: 'Segoe UI Emoji';\"\u003e🛠️\u003c\/span\u003e HVAC Depot Pro Tip\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eGas valves should \u003cb\u003enot be matched by appearance or pipe size alone\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor the \u003cb\u003e13H3301\u003c\/b\u003e, verify these primary specifications before ordering:\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCat #: 13H33\u003c\/b\u003e\u003cbr\u003e\u003cb\u003ePart #: 13H3301\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eVoltage: 24 VAC\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eConnection: 1\/2\" NPT\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eIgnition: Electronic Ignition\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eAlso verify the furnace model and serial number, fuel type, inlet\/outlet configuration, required manifold pressure, electrical connections, and original gas-valve specifications.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eGas valve installation, leak testing, combustion checks, and manifold-pressure adjustments should be performed according to the equipment manufacturer's service procedures and applicable codes.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment \/ Model Compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eLennox 13H33 \/ 13H3301\u003c\/b\u003e is designed for select Lennox gas-fired HVAC equipment requiring this specific \u003cb\u003e24 VAC electronic-ignition gas valve\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eApplications may include compatible:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eLennox gas furnaces\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eResidential heating equipment\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eElectronic-ignition furnace systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eGas burner assemblies\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eLennox equipment specifically calling for \u003cb\u003e13H3301\u003c\/b\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eAlways verify the complete equipment model and serial number before ordering.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Lennox","offers":[{"title":"Default Title","offer_id":53972870889835,"sku":"66255111518","price":795.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/13H33.jpg?v=1790874016"},{"product_id":"lennox-16y31-105601-01-oem-natural-gas-valve-3-4-x-3-4-24-vac-2-stage-fast-open","title":"Lennox 16Y31 \/ 105601-01 OEM Natural Gas Valve – 3\/4\" x 3\/4\", 24 VAC, 2-Stage, Fast Open","description":"\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eLennox 16Y31\u003c\/b\u003e, model\/part \u003cb\u003e105601-01\u003c\/b\u003e, is a genuine OEM \u003cb\u003etwo-stage natural gas valve\u003c\/b\u003e designed for select Lennox gas furnaces and heating equipment. It operates on \u003cb\u003e24 VAC\u003c\/b\u003e and features \u003cb\u003e3\/4\" x 3\/4\" gas connections\u003c\/b\u003e with fast-opening operation.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis gas valve controls the flow of natural gas to the furnace burner assembly. Its \u003cb\u003etwo-stage design\u003c\/b\u003e allows compatible furnaces to operate at low and high heating stages, helping the heating system adjust its output based on demand.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features \u0026amp; Function\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eGenuine \u003cb\u003eLennox OEM\u003c\/b\u003e gas valve\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eCat #: 16Y31\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eModel \/ Part #: 105601-01\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for \u003cb\u003enatural gas\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e24 VAC\u003c\/b\u003e operation\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e2-stage\u003c\/b\u003e gas valve\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003eFast-open\u003c\/b\u003e operation\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003e3\/4\" x 3\/4\" connections\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eControls natural gas flow to furnace burners\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eSupports low and high heating stages\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for compatible Lennox gas furnaces\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eOEM furnace service replacement component\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Details \u0026amp; Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eBrand\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eLennox\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCatalog Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e16Y31\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eModel \/ Part Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e105601-01\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eGas Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eFuel Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eNatural Gas\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eVoltage\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e24 VAC\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eStages\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e2-Stage\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eOpening Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eFast Open\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eInlet Connection\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e3\/4\"\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eOutlet Connection\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e3\/4\"\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eConnection Configuration\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e3\/4\" x 3\/4\"\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 12;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eApplication\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eGas Furnace \/ Heating Equipment\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 13;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eFunction\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eControls Gas Flow to Burner Assembly\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 14; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eOEM Component\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Segoe UI Emoji',sans-serif; mso-bidi-font-family: 'Segoe UI Emoji';\"\u003e🛠️\u003c\/span\u003e HVAC Depot Pro Tip\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eDo not match a furnace gas valve by pipe size alone. A replacement must also match the \u003cb\u003efuel type, voltage, staging, operating characteristics, and equipment requirements\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor this valve, the primary identifiers are:\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCat #: 16Y31\u003c\/b\u003e\u003cbr\u003e\u003cb\u003ePart #: 105601-01\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eFuel: Natural Gas\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eVoltage: 24 VAC\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eStages: 2-Stage\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eConnections: 3\/4\" x 3\/4\"\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eOperation: Fast Open\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis is a \u003cb\u003etwo-stage valve\u003c\/b\u003e, so it should not be substituted with a standard single-stage gas valve simply because the connections and voltage are the same.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eGas-valve installation and adjustment should follow Lennox service procedures and applicable fuel-gas codes, including proper leak testing and verification of manifold pressure and combustion.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment \/ Model Compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eLennox 16Y31 \/ 105601-01\u003c\/b\u003e is intended for select Lennox gas-fired equipment requiring a \u003cb\u003e24 VAC, two-stage natural gas valve with 3\/4\" connections\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eTypical applications include compatible:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eLennox gas furnaces\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eTwo-stage furnaces\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eNatural gas heating systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eElectronic ignition systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eResidential forced-air heating equipment\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eLennox equipment specifically calling for \u003cb\u003e105601-01\u003c\/b\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eAlways verify the complete furnace \u003cb\u003emodel and serial number\u003c\/b\u003e before ordering.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Lennox","offers":[{"title":"Default Title","offer_id":53972892025195,"sku":"66255154380","price":300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/16Y31.jpg?v=1790874957"},{"product_id":"lennox-103181-02-white-rodgers-36j55-255-2-stage-gas-valve-natural-gas-24-vac-1-2-npt-pipe-size","title":"Lennox 103181-02, White Rodgers 36J55-255, 2-Stage Gas Valve, Natural Gas, 24 VAC, 1\/2\" NPT Pipe Size","description":"\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eLennox 83W12\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, model\/part \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e103181-02\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, is an OEM \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003etwo-stage natural gas valve\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e manufactured by \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eWhite-Rodgers\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, model \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e36J55-255\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, for select Lennox gas furnaces and heating equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eOperating on \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e24 VAC\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e1\/2-inch NPT gas connections\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, this valve regulates natural gas flow to the burner assembly. Its \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003etwo-stage design\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e supports low- and high-fire operation in compatible furnaces, allowing the heating system to adjust burner output according to heating demand.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"Heading-Ro3lZr\" dir=\"auto\"\u003e\u003cspan\u003eKey Features \u0026amp; Function\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul dir=\"auto\" class=\"List-kOVW5V UnorderedList-nqKD7g\"\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cspan\u003eGenuine \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eLennox OEM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e replacement component\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cspan\u003eManufactured by \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eWhite-Rodgers\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eLennox Cat #: 83W12\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eLennox Part #: 103181-02\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eWhite-Rodgers Model: 36J55-255\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cspan\u003eDesigned for \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003enatural gas\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e24 VAC\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e operation\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e2-stage\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e gas valve\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e1\/2\" NPT\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e pipe connection\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eSupports low- and high-stage heating\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eControls natural gas flow to the burner assembly\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eDesigned for compatible Lennox gas furnaces\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eProfessional HVAC replacement component\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"Heading-Ro3lZr\" dir=\"auto\"\u003e\u003cspan\u003eProduct Details \u0026amp; Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"group\/app-widget pointer-coarse:pt-11 [@media(hover:none)]:pt-11 TableContainer-UfIOz_\" data-markdown-table=\"true\" data-wide-block=\"\" tabindex=\"-1\"\u003e\n\u003cdiv class=\"TableScroller-ZhMTLB\"\u003e\n\u003cdiv class=\"TableWrapper-i1mUIE\"\u003e\n\u003ctable class=\"Table-LqdUhs\" dir=\"auto\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003cth class=\"TableHeaderCell-esYSpn SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth class=\"TableHeaderCell-esYSpn SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody class=\"TableBody-A5sMNL\"\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cspan\u003eLennox\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eValve Manufacturer\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cspan\u003eWhite-Rodgers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eCatalog Number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e83W12\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eLennox Part Number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e103181-02\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eWhite-Rodgers Model\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e36J55-255\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cspan\u003eFurnace Gas Valve\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eFuel Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eNatural Gas\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e24 VAC\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eStages\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e2-Stage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003ePipe Size\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e1\/2\" NPT\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eApplication\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cspan\u003eGas Furnace \/ Heating Equipment\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eFunction\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cspan\u003eControls Gas Flow to Burner Assembly\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eOEM Replacement\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"absolute end-0 top-0 z-50 flex w-fit select-none items-center gap-1 rounded-full bg-surface p-0.5 text-tertiary pointer-events-none opacity-0 group-hover\/app-widget:pointer-events-auto group-hover\/app-widget:opacity-100 focus-within:pointer-events-auto focus-within:opacity-100 data-[visible=true]:pointer-events-auto data-[visible=true]:opacity-100 has-data-[state=open]:pointer-events-auto has-data-[state=open]:opacity-100 pointer-coarse:pointer-events-auto pointer-coarse:opacity-100 [@media(hover:none)]:pointer-events-auto [@media(hover:none)]:opacity-100\" data-block-actions=\"true\" data-markdown-copy=\"exclude\"\u003e\n\u003cspan data-state=\"closed\" class=\"contents\"\u003e\u003cbutton type=\"button\" class=\"no-drag cursor-interaction items-center select-none disabled:cursor-default aria-disabled:cursor-default focus:outline-hidden disabled:opacity-40 aria-disabled:opacity-40 focus-visible:ring-2 focus-visible:ring-ring focus-visible:ring-offset-0 whitespace-nowrap flex border gap-1 rounded-full text-tertiary not-disabled:not-aria-disabled:hover:bg-primary-ghost-hover not-disabled:not-aria-disabled:hover:text-default data-[state=open]:bg-primary-ghost-hover border-transparent size-9 justify-center border-0 p-0\"\u003e\u003cspan class=\"LeadingSource-d79mNZ\"\u003e\u003c\/span\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan data-state=\"closed\" class=\"contents\"\u003e\u003cbutton type=\"button\" class=\"no-drag cursor-interaction items-center select-none disabled:cursor-default aria-disabled:cursor-default focus:outline-hidden disabled:opacity-40 aria-disabled:opacity-40 focus-visible:ring-2 focus-visible:ring-ring focus-visible:ring-offset-0 whitespace-nowrap flex border gap-1 rounded-full text-tertiary not-disabled:not-aria-disabled:hover:bg-primary-ghost-hover not-disabled:not-aria-disabled:hover:text-default data-[state=open]:bg-primary-ghost-hover border-transparent size-9 justify-center border-0 p-0\"\u003e\u003cspan class=\"LeadingSource-d79mNZ\"\u003e\u003csvg class=\"Icon-X4VkKC\" height=\"20\" viewbox=\"0 0 20 20\" width=\"20\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003c\/button\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"Heading-Ro3lZr\" dir=\"auto\"\u003e\u003cspan\u003e🛠️ HVAC Depot Pro Tip\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eDo not select a furnace gas valve by \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003evoltage and pipe size alone\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Two valves can both be 24 VAC and 1\/2\" NPT while having different staging, pressure settings, electrical configurations, or furnace applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eFor this valve, match these primary identifiers:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eLennox Cat #: 83W12\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eLennox Part #: 103181-02\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eWhite-Rodgers #: 36J55-255\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eFuel: Natural Gas\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eVoltage: 24 VAC\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eStages: 2-Stage\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003ePipe Size: 1\/2\" NPT\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eBecause this is a \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003etwo-stage gas valve\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, verify both low- and high-stage operation when diagnosing the furnace.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eGas-valve installation should follow the furnace manufacturer's service procedures and applicable fuel-gas codes. Proper leak testing, manifold-pressure verification, and combustion checks are required after replacement.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"Heading-Ro3lZr\" dir=\"auto\"\u003e\u003cspan\u003eEquipment \/ Model Compatibility\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eLennox 83W12 \/ 103181-02 \/ White-Rodgers 36J55-255\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is designed for select Lennox gas-fired equipment requiring this specific two-stage natural gas valve.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eTypical applications include compatible:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul dir=\"auto\" class=\"List-kOVW5V UnorderedList-nqKD7g\"\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eLennox gas furnaces\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eTwo-stage gas furnaces\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eNatural gas heating systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eElectronic ignition systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eResidential forced-air heating equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cspan\u003eLennox equipment specifically calling for \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e103181-02\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cspan\u003eEquipment using \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eWhite-Rodgers 36J55-255\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eAlways verify the complete furnace \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003emodel and serial number\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e before ordering.\u003c\/span\u003e\u003c\/p\u003e","brand":"Lennox","offers":[{"title":"Default Title","offer_id":53972968898923,"sku":"83W12","price":215.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/83W12.jpg?v=1790875816"},{"product_id":"lennox-18m65-18m6501-honeywell-vr8205q-2746-oem-2-stage-natural-gas-valve-150-000-btuh-24-vac-1-2-npt","title":"Lennox 18M65 \/ 18M6501 Honeywell VR8205Q-2746 OEM 2-Stage Natural Gas Valve – 150,000 BTUH, 24 VAC, 1\/2\" NPT","description":"\u003ch1 class=\"MsoNormal\"\u003e\u003cb\u003eLennox 18M65 \/ 18M6501 Honeywell VR8205Q-2746 OEM 2-Stage Natural Gas Valve – 150,000 BTUH, 24 VAC, 1\/2\" NPT\u003c\/b\u003e\u003c\/h1\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Description\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eLennox 18M65\u003c\/b\u003e, model\/part \u003cb\u003e18M6501\u003c\/b\u003e, is an OEM \u003cb\u003etwo-stage natural gas valve\u003c\/b\u003e manufactured by \u003cb\u003eHoneywell\u003c\/b\u003e, model \u003cb\u003eVR8205Q-2746\u003c\/b\u003e, for select Lennox gas furnaces and heating equipment.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eRated for \u003cb\u003e150,000 BTUH natural gas applications\u003c\/b\u003e, this valve operates on \u003cb\u003e24 VAC\u003c\/b\u003e and features \u003cb\u003e1\/2\"-14 NPT pipe connections\u003c\/b\u003e. Its two-stage design controls gas flow to the burner assembly during low- and high-stage heating operation, allowing compatible furnaces to adjust heating output according to demand.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features \u0026amp; Function\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eGenuine \u003cb\u003eLennox OEM\u003c\/b\u003e replacement component\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eManufactured by \u003cb\u003eHoneywell\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eLennox Cat #: 18M65\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eLennox Part #: 18M6501\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eHoneywell Model: VR8205Q-2746\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003eNatural gas\u003c\/b\u003e application\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e150,000 BTUH\u003c\/b\u003e capacity\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e24 VAC\u003c\/b\u003e operation\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e2-stage\u003c\/b\u003e gas valve\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e1\/2\"-14 NPT\u003c\/b\u003e pipe size\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eControls natural gas flow to furnace burners\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eSupports low- and high-stage heating\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for compatible Lennox gas furnaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Details \u0026amp; Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eBrand\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eLennox\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eValve Manufacturer\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHoneywell\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCatalog Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e18M65\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eLennox Part Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e18M6501\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eHoneywell Model\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eVR8205Q-2746\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eFurnace Gas Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eFuel Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eNatural Gas\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCapacity\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e150,000 BTUH\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eVoltage\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e24 VAC\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eStages\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e2-Stage\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003ePipe Size\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e1\/2\"-14 NPT\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 12;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eApplication\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eGas Furnace \/ Heating Equipment\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 13;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eFunction\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eControls Natural Gas Flow to Burner Assembly\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 14; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eOEM Replacement\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Segoe UI Emoji',sans-serif; mso-bidi-font-family: 'Segoe UI Emoji';\"\u003e🛠️\u003c\/span\u003e HVAC Depot Pro Tip\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eDo not select a furnace gas valve based only on its \u003cb\u003e24 VAC rating and 1\/2-inch connection\u003c\/b\u003e. Gas valves with similar physical dimensions can have different staging, pressure characteristics, capacities, fuel requirements, and control configurations.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor this valve, match these primary identifiers:\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eLennox Cat #: 18M65\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eLennox Part #: 18M6501\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eHoneywell #: VR8205Q-2746\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eFuel: Natural Gas\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eCapacity: 150,000 BTUH\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eVoltage: 24 VAC\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eStages: 2-Stage\u003c\/b\u003e\u003cbr\u003e\u003cb\u003ePipe Size: 1\/2\"-14 NPT\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBecause this is a \u003cb\u003etwo-stage gas valve\u003c\/b\u003e, proper furnace diagnosis should include verification of both low- and high-stage operation.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eGas valve replacement should include proper leak testing, manifold-pressure verification, and combustion testing according to the furnace manufacturer's procedures and applicable codes.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment \/ Model Compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eLennox 18M65 \/ 18M6501 \/ Honeywell VR8205Q-2746\u003c\/b\u003e is used with select Lennox gas furnaces, including applications within the:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list .5in;\"\u003e\u003cb\u003eG60UH Series\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list .5in;\"\u003e\u003cb\u003eG60UHV Series\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list .5in;\"\u003e\u003cb\u003eG60DF Series\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list .5in;\"\u003e\u003cb\u003eG60DFV Series\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eDocumented model applications include select:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eG60UH24A045\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eG60UH24A070\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eG60UH36A070\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eG60UH36B090\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eG60UH36C110\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eG60UH48B070\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eG60UH48B090\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eG60UH60D135\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eG60UHV36A070\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eG60UHV60C090\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eG60UHV60C110\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eG60UHV60D135\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eG60DF36A070\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eG60DF60C110\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eG60DFV36B090\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eG60DFV60C090\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eG60DFV60C110\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eG60DFV60D135\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eAlways verify the complete furnace \u003cb\u003emodel and serial number\u003c\/b\u003e before ordering.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Lennox","offers":[{"title":"Default Title","offer_id":53973580317035,"sku":"66255133323","price":658.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/18M65.jpg?v=1790889506"},{"product_id":"lennox-60j59-60j5901-honeywell-vr8205m2823-b-natural-gas-valve-24-vac-1-2-x-1-2-3-5-wc","title":"Lennox 60J59 \/ 60J5901 Honeywell VR8205M2823\/B Natural Gas Valve – 24 VAC, 1\/2\" x 1\/2\", 3.5\" WC","description":"\u003ch2 class=\"Heading-Ro3lZr\" dir=\"auto\"\u003e\u003cspan\u003eSEO Product Title\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eLennox 60J59 \/ 60J5901 Honeywell VR8205M2823\/B Natural Gas Valve – 24 VAC, 1\/2\" x 1\/2\", 3.5\" WC\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 class=\"Heading-Ro3lZr\" dir=\"auto\"\u003e\u003cspan\u003eProduct Description\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eLennox 60J59\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, model\/part \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e60J5901\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, is a Lennox-approved \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eHoneywell VR8205M2823\/B gas valve\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e designed for select Lennox furnaces and unit heaters. Lennox specifies it as an \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eintermittent\/direct ignition gas valve\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e operating on \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e24 VAC\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e1\/2\" x 1\/2\" inlet\/outlet connections\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and a \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e3.5\" WC setting\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan class=\"contents\" data-chatgpt-copy-reference=\"0\" data-markdown-copy=\"contents\"\u003e\u003cspan data-state=\"closed\" class=\"contents\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eThe valve controls natural gas flow to the burner during the heating sequence. It uses a standard-opening design and is intended for compatible direct-ignition HVAC applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"Heading-Ro3lZr\" dir=\"auto\"\u003e\u003cspan\u003eKey Features \u0026amp; Function\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul dir=\"auto\" class=\"List-kOVW5V UnorderedList-nqKD7g\"\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eLennox-approved OEM replacement\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cspan\u003eManufactured by \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eCat #: 60J59\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eLennox Part #: 60J5901\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eHoneywell Model: VR8205M2823\/B\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eNatural gas valve\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e24 VAC\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e0.3 Amp\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e50\/60 Hz\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e1\/2\" x 1\/2\" inlet\/outlet\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e3.5\" WC setting\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eIntermittent \/ direct ignition\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eDual direct ignition design\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eStandard opening\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cspan\u003eMounting position: \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e0° to 90°\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cspan\u003eDesigned for compatible Lennox furnaces and heating equipment \u003c\/span\u003e\u003cspan class=\"contents\" data-chatgpt-copy-reference=\"1\" data-markdown-copy=\"contents\"\u003e\u003cspan data-state=\"closed\" class=\"contents\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"Heading-Ro3lZr\" dir=\"auto\"\u003e\u003cspan\u003eProduct Details \u0026amp; Key Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"group\/app-widget pointer-coarse:pt-11 [@media(hover:none)]:pt-11 TableContainer-UfIOz_\" data-markdown-table=\"true\" data-wide-block=\"\" tabindex=\"-1\"\u003e\n\u003cdiv class=\"TableScroller-ZhMTLB\"\u003e\n\u003cdiv class=\"TableWrapper-i1mUIE\"\u003e\n\u003ctable class=\"Table-LqdUhs\" dir=\"auto\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003cth class=\"TableHeaderCell-esYSpn SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth class=\"TableHeaderCell-esYSpn SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody class=\"TableBody-A5sMNL\"\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cspan\u003eLennox\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eValve Manufacturer\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eCatalog Number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e60J59\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eLennox Part Number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e60J5901\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eHoneywell Model\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eVR8205M2823\/B\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cspan\u003eGas Valve\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eFuel Application\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eNatural Gas\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e24 VAC\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eAmperage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e0.3A\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eFrequency\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e50\/60 Hz\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eInlet \/ Outlet\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e1\/2\" x 1\/2\"\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003ePressure Setting\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e3.5\" WC\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eIgnition Application\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cspan\u003eIntermittent \/ Direct Ignition\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eOpening\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cspan\u003eStandard\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cspan\u003e0°–90°\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"TableRow-ENsaGm\"\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eApplication\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"TableCell-WcsygL SingleChildTableCell-Sv7jTC\" dir=\"auto\" data-col-size=\"sm\"\u003e\u003cspan\u003eFurnace \/ Unit Heater\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"absolute end-0 top-0 z-50 flex w-fit select-none items-center gap-1 rounded-full bg-surface p-0.5 text-tertiary pointer-events-none opacity-0 group-hover\/app-widget:pointer-events-auto group-hover\/app-widget:opacity-100 focus-within:pointer-events-auto focus-within:opacity-100 data-[visible=true]:pointer-events-auto data-[visible=true]:opacity-100 has-data-[state=open]:pointer-events-auto has-data-[state=open]:opacity-100 pointer-coarse:pointer-events-auto pointer-coarse:opacity-100 [@media(hover:none)]:pointer-events-auto [@media(hover:none)]:opacity-100\" data-block-actions=\"true\" data-markdown-copy=\"exclude\"\u003e\n\u003cspan data-state=\"closed\" class=\"contents\"\u003e\u003cbutton type=\"button\" class=\"no-drag cursor-interaction items-center select-none disabled:cursor-default aria-disabled:cursor-default focus:outline-hidden disabled:opacity-40 aria-disabled:opacity-40 focus-visible:ring-2 focus-visible:ring-ring focus-visible:ring-offset-0 whitespace-nowrap flex border gap-1 rounded-full text-tertiary not-disabled:not-aria-disabled:hover:bg-primary-ghost-hover not-disabled:not-aria-disabled:hover:text-default data-[state=open]:bg-primary-ghost-hover border-transparent size-9 justify-center border-0 p-0\"\u003e\u003cspan class=\"LeadingSource-d79mNZ\"\u003e\u003c\/span\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan data-state=\"closed\" class=\"contents\"\u003e\u003cbutton type=\"button\" class=\"no-drag cursor-interaction items-center select-none disabled:cursor-default aria-disabled:cursor-default focus:outline-hidden disabled:opacity-40 aria-disabled:opacity-40 focus-visible:ring-2 focus-visible:ring-ring focus-visible:ring-offset-0 whitespace-nowrap flex border gap-1 rounded-full text-tertiary not-disabled:not-aria-disabled:hover:bg-primary-ghost-hover not-disabled:not-aria-disabled:hover:text-default data-[state=open]:bg-primary-ghost-hover border-transparent size-9 justify-center border-0 p-0\"\u003e\u003cspan class=\"LeadingSource-d79mNZ\"\u003e\u003csvg class=\"Icon-X4VkKC\" height=\"20\" viewbox=\"0 0 20 20\" width=\"20\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003c\/button\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eLennox currently lists these electrical, connection, ignition, and physical specifications for 60J59. \u003c\/span\u003e\u003cspan class=\"contents\" data-chatgpt-copy-reference=\"2\" data-markdown-copy=\"contents\"\u003e\u003cspan data-state=\"closed\" class=\"contents\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"Heading-Ro3lZr\" dir=\"auto\"\u003e\u003cspan\u003e🛠️ HVAC Depot Pro Tip\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eDo not match the \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e60J59\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e by its 1\/2\" connections alone. Confirm the original valve and furnace specifications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eThe primary identifiers are:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eCat #: \u003c\/span\u003e\u003cspan data-markdown-copy=\"inline-code\" class=\"InlineCode-Cddi3Y InlineMarkdownIsolate-QWDV4W\" dir=\"ltr\"\u003e60J59\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eLennox Part #: \u003c\/span\u003e\u003cspan data-markdown-copy=\"inline-code\" class=\"InlineCode-Cddi3Y InlineMarkdownIsolate-QWDV4W\" dir=\"ltr\"\u003e60J5901\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eHoneywell #: \u003c\/span\u003e\u003cspan data-markdown-copy=\"inline-code\" class=\"InlineCode-Cddi3Y InlineMarkdownIsolate-QWDV4W\" dir=\"ltr\"\u003eVR8205M2823\/B\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eVoltage: 24 VAC\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eConnections: 1\/2\" x 1\/2\"\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eSetting: 3.5\" WC\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e3.5\" WC specification is a gas-pressure setting\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, not the incoming supply pressure. After replacement, proper inlet pressure, manifold pressure, gas leaks, ignition, and combustion should be checked according to the equipment service procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"Heading-Ro3lZr\" dir=\"auto\"\u003e\u003cspan\u003eEquipment \/ Model Compatibility\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e60J59\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is documented for select Lennox furnaces and unit heaters. Examples include equipment in the \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e80MGF\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e family and \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eLF24\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e unit-heater family, including models such as:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul dir=\"auto\" class=\"List-kOVW5V UnorderedList-nqKD7g\"\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003e80MGF3-75A-1\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003e80UHG3-75A-3\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eLF24-100A-5\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eLF24-125A-5\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eLF24-145A-5\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eLF24-150A-5\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eLF24-200A-6\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eLF24-30A-4\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eLF24-30A-5\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cspan\u003eLF24-45A-4 \u003c\/span\u003e\u003cspan class=\"contents\" data-chatgpt-copy-reference=\"3\" data-markdown-copy=\"contents\"\u003e\u003cspan data-state=\"closed\" class=\"contents\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eAlways verify the complete furnace or unit-heater model and serial number before ordering.\u003c\/span\u003e\u003c\/p\u003e","brand":"Lennox","offers":[{"title":"Default Title","offer_id":53973731049835,"sku":"60J59","price":185.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/60J59.jpg?v=1790893960"},{"product_id":"lennox-60j92-65314900-oem-propane-gas-valve-3-4-npt-24v-step-opening-dual-valv","title":"Lennox 60J92 \/ 65314900 OEM Propane Gas Valve – 3\/4\" NPT, 24V, Step-Opening Dual Valv","description":"\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eLennox 60J92\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, model\/part \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e65314900\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, is a genuine OEM \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eLP propane gas valve\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e designed for select Lennox gas-fired heating equipment. Lennox identifies the catalog number as \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e60J92\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and the factory model\/part number as \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e65314900\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan class=\"contents\" data-chatgpt-copy-reference=\"0\" data-markdown-copy=\"contents\"\u003e\u003cspan data-state=\"closed\" class=\"contents\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eThis valve operates on \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e24 volts\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and uses a \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e3\/4-inch connection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with a \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003estep-opening dual-valve design\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Current OEM-parts documentation identifies the 60J92 specifically for \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eLP\/propane gas applications\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan class=\"contents\" data-chatgpt-copy-reference=\"1\" data-markdown-copy=\"contents\"\u003e\u003cspan data-state=\"closed\" class=\"contents\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"Heading-Ro3lZr\" dir=\"auto\"\u003e\u003cspan\u003eKey Features \u0026amp; Function\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul dir=\"auto\" class=\"List-kOVW5V UnorderedList-nqKD7g\"\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cspan\u003eGenuine \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eLennox OEM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e component\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eCat #: 60J92\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eModel \/ Part #: 65314900\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eLP \/ propane gas\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e application\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e24V\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e operation\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e50\/60 Hz\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e3\/4\" NPT\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e connection\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eStep-opening\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e operation\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eDual gas valve design\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eControls propane flow to the burner assembly\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eDesigned for compatible Lennox gas-fired heating equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eThe 24V, 3\/4-inch, LP and step-opening dual-valve specifications are consistently documented for 60J92. \u003c\/span\u003e\u003cspan class=\"contents\" data-chatgpt-copy-reference=\"2\" data-markdown-copy=\"contents\"\u003e\u003cspan data-state=\"closed\" class=\"contents\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"Heading-Ro3lZr\" dir=\"auto\"\u003e\u003cspan\u003e🛠️ HVAC Depot Pro Tip\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eThe most important detail with \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e60J92\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is the fuel type: this OEM valve is specified for \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eLP \/ propane gas\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Do not confuse it with a natural-gas valve that may have the same 24V electrical rating and 3\/4-inch connections.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eMatch:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eCat #: \u003c\/span\u003e\u003cspan data-markdown-copy=\"inline-code\" class=\"InlineCode-Cddi3Y InlineMarkdownIsolate-QWDV4W\" dir=\"ltr\"\u003e60J92\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003ePart #: \u003c\/span\u003e\u003cspan data-markdown-copy=\"inline-code\" class=\"InlineCode-Cddi3Y InlineMarkdownIsolate-QWDV4W\" dir=\"ltr\"\u003e65314900\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eFuel: LP \/ Propane\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eVoltage: 24V\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eConnection: 3\/4\" NPT\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eOperation: Step Opening\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eValve Type: Dual Valve\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eAlso be careful with \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e60J9201\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. White-Rodgers cross-reference documentation lists 60J9201 separately and suggests \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e36C74-913\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e as a replacement reference; that does not change the OEM Lennox MPN for the product being listed here, which is \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e65314900\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan class=\"contents\" data-chatgpt-copy-reference=\"3\" data-markdown-copy=\"contents\"\u003e\u003cspan data-state=\"closed\" class=\"contents\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center font-sans select-none relative top-[-0.094rem] translate-y-0.5\" data-search-result-target=\"\"\u003e\u003ca data-testid=\"chatgpt-citation\" class=\"no-underline! group cursor-interaction hover:bg-secondary-soft-hover hover:text-default! flex h-4.5 max-w-[15rem] overflow-hidden rounded-xl pe-2 ps-1 text-[9px] leading-none font-medium select-none bg-secondary-soft text-secondary-solid!\" href=\"https:\/\/media.copeland.com\/9ee34fc4-c3b5-459e-a826-b16d003ee850\/R-4853%20%20-%20WR%20Heating%20Season%20Cross%20Ref.pdf?utm_source=chatgpt.com\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cspan class=\"relative start-0 bottom-0 flex h-full w-full items-center\"\u003e\u003cspan class=\"flex min-w-0 flex-1 items-center gap-1\"\u003e\u003cspan class=\"Favicon-xZwQNw inline-block shrink-0 rounded-2xs size-3 overflow-hidden rounded-full text-current [\u0026amp;\u0026gt;img]:rounded-full size-3 overflow-hidden rounded-full text-current [\u0026amp;\u0026gt;img]:rounded-full\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eGas-valve installation should include proper leak testing, inlet\/manifold-pressure verification, ignition checks and combustion testing according to the equipment manufacturer's procedures and applicable codes.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"Heading-Ro3lZr\" dir=\"auto\"\u003e\u003cspan\u003eEquipment \/ Model Compatibility\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003eLennox 60J92 \/ 65314900\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is used with select Lennox gas-fired heating equipment requiring a \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e24V, 3\/4-inch LP step-opening dual gas valve\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eApplications may include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul dir=\"auto\" class=\"List-kOVW5V UnorderedList-nqKD7g\"\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eLennox gas heating equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eLP \/ propane furnaces\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003eUnit heaters\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\u003cspan\u003ePropane-fired HVAC equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cspan\u003eEquipment specifically calling for \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e60J92\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItem-ncLgmg\"\u003e\n\u003cspan\u003eEquipment specifically calling for \u003c\/span\u003e\u003cstrong class=\"font-semibold\"\u003e\u003cspan\u003e65314900\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"Paragraph-kKnbIo\" dir=\"auto\"\u003e\u003cspan\u003eAlways verify the complete equipment model and serial number before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lennox","offers":[{"title":"Default Title","offer_id":53973838758251,"sku":"60J92","price":425.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/60J92.jpg?v=1790896203"},{"product_id":"lennox-allied-70l53-20256701-oem-natural-gas-smartvalve-24v-1-2-x-1-2-npt-intermittent-hot-surface-pilot-ignition","title":"Lennox \/ Allied 70L53 \/ 20256701 OEM Natural Gas SmartValve – 24V, 1\/2\" x 1\/2\" NPT, Intermittent Hot Surface Pilot Ignition","description":"\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eLennox \/ Allied 70L53\u003c\/b\u003e, model\/part \u003cb\u003e20256701\u003c\/b\u003e, is an OEM \u003cb\u003enatural gas valve and ignition control assembly\u003c\/b\u003e designed for select Lennox and Allied gas-fired heating equipment.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis valve operates on \u003cb\u003e24 VAC\u003c\/b\u003e and features \u003cb\u003e1\/2\" x 1\/2\" NPT gas connections\u003c\/b\u003e. It is designed for \u003cb\u003eintermittent hot surface pilot ignition\u003c\/b\u003e applications and uses a SmartValve-style configuration that integrates gas-flow control with the furnace ignition sequence.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features \u0026amp; Function\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eGenuine \u003cb\u003eLennox \/ Allied OEM\u003c\/b\u003e replacement component\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eCat #: 70L53\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eModel \/ Part #: 20256701\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eNatural gas application\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e24 VAC\u003c\/b\u003e operation\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003e50\/60 Hz\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e1\/2\" x 1\/2\" NPT\u003c\/b\u003e connections\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eIntermittent hot surface pilot ignition\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eSmartValve-style gas control\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eSlow-opening operation\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eControls natural gas flow to the burner assembly\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eWorks with the furnace ignition sequence\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for compatible Lennox and Allied heating equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Details \u0026amp; Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eBrand\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eLennox \/ Allied\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCatalog Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e70L53\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eModel \/ Part Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e20256701\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eGas Valve \/ Ignition Control\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eFuel Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eNatural Gas\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eVoltage\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e24 VAC\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eFrequency\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e50\/60 Hz\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eInlet Connection\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e1\/2\" NPT\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eOutlet Connection\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e1\/2\" NPT\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eConnection Configuration\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e1\/2\" x 1\/2\" NPT\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eIgnition Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eIntermittent Hot Surface Pilot\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 12;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eValve Operation\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSlow Opening\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 13;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eControl Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eSmartValve-Style\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 14;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eApplication\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eFurnace \/ Gas Heating Equipment\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 15; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eOEM Component\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Segoe UI Emoji',sans-serif; mso-bidi-font-family: 'Segoe UI Emoji';\"\u003e🛠️\u003c\/span\u003e HVAC Depot Pro Tip\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003e70L53 \/ 20256701 is not simply a standard 24V furnace gas valve\u003c\/b\u003e. Its ignition-control configuration is an important part of the application.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWhen replacing this valve, verify:\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCat #: 70L53\u003c\/b\u003e\u003cbr\u003e\u003cb\u003ePart #: 20256701\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eFuel: Natural Gas\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eVoltage: 24 VAC\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eFrequency: 50\/60 Hz\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eConnections: 1\/2\" x 1\/2\" NPT\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eIgnition: Intermittent Hot Surface Pilot\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eDo not substitute a conventional 24V gas valve simply because the voltage and pipe connections are the same.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eGas-valve installation should include proper leak testing, inlet and manifold-pressure verification, ignition testing, and combustion checks according to the equipment manufacturer's procedures and applicable codes.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment \/ Model Compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eLennox \/ Allied 70L53 \/ 20256701\u003c\/b\u003e is designed for select gas-fired heating equipment requiring this specific gas valve and ignition-control configuration.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eApplications include select:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eLennox heating equipment\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eAllied heating equipment\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eGas furnaces\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eIntermittent hot surface pilot systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eSmartValve-style ignition systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003e\n\u003cb\u003eFPBB Series\u003c\/b\u003e equipment\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003e\u003cb\u003eFPBB075A3\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003e\u003cb\u003eFPBB100A4\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eEquipment specifically calling for \u003cb\u003e20256701\u003c\/b\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eAlways verify the complete equipment \u003cb\u003emodel and serial number\u003c\/b\u003e before ordering.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Lennox","offers":[{"title":"Default Title","offer_id":53973852815723,"sku":"66255134048","price":1300.0,"currency_code":"USD","in_stock":true}]},{"product_id":"lennox-11l08-103181-05-white-rodgers-36j54-504b1-oem-2-stage-natural-gas-valve-24-vac-1-2-npt","title":"Lennox 11L08 \/ 103181-05 White-Rodgers 36J54-504B1 OEM 2-Stage Natural Gas Valve – 24 VAC, 1\/2\" NPT","description":"\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eLennox 11L08\u003c\/b\u003e, model\/part \u003cb\u003e103181-05\u003c\/b\u003e, is an OEM \u003cb\u003eWhite-Rodgers 36J54-504B1 two-stage natural gas valve\u003c\/b\u003e designed for select Lennox gas-fired heating equipment.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eOperating on \u003cb\u003e24 VAC\u003c\/b\u003e with a \u003cb\u003e1\/2\" NPT pipe size\u003c\/b\u003e, this valve controls natural gas flow to the burner assembly during first- and second-stage heating operation. The two-stage design allows compatible furnaces to operate at low and high heating outputs based on demand.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features \u0026amp; Function\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eGenuine \u003cb\u003eLennox OEM\u003c\/b\u003e replacement component\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eManufactured by \u003cb\u003eWhite-Rodgers\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eCat #: 11L08\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eLennox Part #: 103181-05\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eWhite-Rodgers #: 36J54-504B1\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003eNatural gas\u003c\/b\u003e application\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e24 VAC\u003c\/b\u003e operation\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e2-stage\u003c\/b\u003e gas control\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e1\/2\" NPT\u003c\/b\u003e pipe size\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eControls gas flow to the furnace burner assembly\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eSupports low- and high-stage heating operation\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for compatible Lennox gas furnaces and heating equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Details \u0026amp; Key Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eBrand\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eLennox\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eManufacturer\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eWhite-Rodgers\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCatalog Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e11L08\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eLennox Part Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e103181-05\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eManufacturer Valve Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e36J54-504B1\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eFurnace Gas Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eFuel Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eNatural Gas\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eVoltage\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e24 VAC\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eStages\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e2-Stage\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003ePipe Size\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e1\/2\" NPT\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eFunction\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eBurner Gas Flow Control\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 12;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eApplication\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eGas Furnace \/ Heating Equipment\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 13; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eOEM Component\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Segoe UI Emoji',sans-serif; mso-bidi-font-family: 'Segoe UI Emoji';\"\u003e🛠️\u003c\/span\u003e HVAC Depot Pro Tip\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eDo not replace the \u003cb\u003e11L08 \/ 103181-05\u003c\/b\u003e with a gas valve simply because it has the same \u003cb\u003e24V electrical rating and 1\/2\" pipe size\u003c\/b\u003e. The replacement also needs to match the \u003cb\u003etwo-stage operation, natural-gas application, ignition\/control configuration, and equipment requirements\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify:\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCatalog Number: 11L08\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eLennox Part Number: 103181-05\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eWhite-Rodgers Number: 36J54-504B1\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eFuel: Natural Gas\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eVoltage: 24 VAC\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eStages: 2-Stage\u003c\/b\u003e\u003cbr\u003e\u003cb\u003ePipe Size: 1\/2\" NPT\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eGas-valve installation should include proper leak testing, inlet and manifold gas-pressure verification, ignition testing, and combustion checks according to the equipment manufacturer's procedures and applicable codes.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment \/ Model Compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eLennox 11L08 \/ 103181-05\u003c\/b\u003e is designed for select Lennox gas-fired heating equipment requiring this specific \u003cb\u003eWhite-Rodgers two-stage natural gas valve\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eSuitable applications include:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eSelect Lennox two-stage gas furnaces\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eNatural-gas heating equipment\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003e24 VAC furnace control systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eTwo-stage burner applications\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eEquipment specifically calling for \u003cb\u003e11L08\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eEquipment specifically calling for \u003cb\u003e103181-05\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eApplications requiring \u003cb\u003e36J54-504B1\u003c\/b\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eAlways verify the complete furnace \u003cb\u003emodel and serial number\u003c\/b\u003e before ordering.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Lennox","offers":[{"title":"Default Title","offer_id":53977511526763,"sku":"66255148198","price":265.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/11L08.jpg?v=1790961309"},{"product_id":"lennox-72w34-103016-01-honeywell-vr9205r2363-oem-modulating-natural-gas-valve-24-vac-1-2-x-1-2-3-5-wc","title":"Lennox 72W34 \/ 103016-01 Honeywell VR9205R2363 OEM Modulating Natural Gas Valve – 24 VAC, 1\/2\" x 1\/2\", 3.5\" WC","description":"\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eLennox 72W34\u003c\/b\u003e, model\/part \u003cb\u003e103016-01\u003c\/b\u003e, is an OEM \u003cb\u003eHoneywell VR9205R2363 modulating natural gas valve\u003c\/b\u003e designed for select Lennox gas-fired heating equipment.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eUnlike a standard single-stage or two-stage gas valve, this \u003cb\u003emodulating valve\u003c\/b\u003e adjusts gas flow in response to the furnace control system. This allows compatible modulating furnaces to vary heating output more precisely according to demand for improved temperature control and system operation.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe valve operates on \u003cb\u003e24 VAC\u003c\/b\u003e, uses \u003cb\u003e1\/2\" x 1\/2\" gas connections\u003c\/b\u003e, and has a maximum regulator setting of \u003cb\u003e3.5 ±0.3 inches W.C.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features \u0026amp; Function\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eGenuine \u003cb\u003eLennox OEM\u003c\/b\u003e replacement component\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eManufactured by \u003cb\u003eHoneywell\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eCat #: 72W34\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eLennox Part #: 103016-01\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eHoneywell Model: VR9205R2363\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eModulating gas valve\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for \u003cb\u003enatural gas\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e24 VAC\u003c\/b\u003e operation\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e1\/2\" x 1\/2\"\u003c\/b\u003e gas connections\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eMaximum regulator setting: \u003cb\u003e3.5 ±0.3\" W.C.\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eProvides variable gas-flow control\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eWorks with compatible modulating furnace controls\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eAdjusts burner input according to heating demand\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for select Lennox modulating gas furnaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Details \u0026amp; Key Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eBrand\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eLennox\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eValve Manufacturer\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHoneywell\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCatalog Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e72W34\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eLennox Part Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e103016-01\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eHoneywell Model\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eVR9205R2363\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eModulating Gas Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eFuel Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eNatural Gas\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eVoltage\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e24 VAC\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eControl Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eModulating\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eInlet Connection\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e1\/2\"\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eOutlet Connection\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e1\/2\"\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 12;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eConnection Configuration\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e1\/2\" x 1\/2\"\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 13;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eMaximum Regulator Setting\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e3.5 ±0.3\" W.C.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 14;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eApplication\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eModulating Gas Furnace\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 15;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eFunction\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVariable Burner Gas-Flow Control\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 16; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eOEM Component\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Segoe UI Emoji',sans-serif; mso-bidi-font-family: 'Segoe UI Emoji';\"\u003e🛠️\u003c\/span\u003e HVAC Depot Pro Tip\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003e72W34 \/ 103016-01 is a modulating gas valve\u003c\/b\u003e, which is an important distinction when selecting a replacement.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eDo \u003cb\u003enot\u003c\/b\u003e substitute a standard single-stage or two-stage 24V gas valve simply because the pipe size and voltage are the same.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eMatch:\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCatalog Number: 72W34\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eLennox Part Number: 103016-01\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eHoneywell Number: VR9205R2363\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eFuel: Natural Gas\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eVoltage: 24 VAC\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eControl: Modulating\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eConnections: 1\/2\" x 1\/2\"\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eMax Regulator Setting: 3.5 ±0.3\" W.C.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe furnace control system must be designed to operate this specific type of modulating valve.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eGas-valve replacement should include leak testing, inlet and manifold gas-pressure verification, ignition testing, modulation testing, and combustion analysis according to the equipment manufacturer's procedures and applicable codes.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment \/ Model Compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eLennox 72W34 \/ 103016-01\u003c\/b\u003e is designed for select \u003cb\u003eLennox modulating gas furnaces\u003c\/b\u003e requiring the Honeywell \u003cb\u003eVR9205R2363\u003c\/b\u003e gas valve.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eTypical applications include:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eSelect Lennox modulating furnaces\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eVariable-capacity gas heating equipment\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eNatural-gas furnace applications\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003e24 VAC modulating gas-control systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eEquipment specifically calling for \u003cb\u003e72W34\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eEquipment specifically calling for \u003cb\u003e103016-01\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eApplications requiring \u003cb\u003eVR9205R2363\u003c\/b\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eAlways verify the complete furnace \u003cb\u003emodel and serial number\u003c\/b\u003e before ordering.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Lennox","offers":[{"title":"Default Title","offer_id":53977545245035,"sku":"66255142290","price":341.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/72W34.jpg?v=1790962348"},{"product_id":"lennox-85k35-85k3501-oem-natural-gas-valve-24v-dual-direct-ignition-3-4-x-3-4-standard-opening","title":"Lennox 85K35 \/ 85K3501 OEM Natural Gas Valve – 24V, Dual Direct Ignition, 3\/4\" x 3\/4\", Standard Opening","description":"\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eLennox 85K35\u003c\/b\u003e, model\/part \u003cb\u003e85K3501\u003c\/b\u003e, is an OEM \u003cb\u003e24V natural gas valve\u003c\/b\u003e designed for compatible Lennox gas-fired heating equipment using a \u003cb\u003edual direct ignition\u003c\/b\u003e system.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis valve features \u003cb\u003e3\/4\" x 3\/4\" inlet and outlet connections\u003c\/b\u003e, standard-opening operation, and a \u003cb\u003e0.62A anticipator setting\u003c\/b\u003e. It controls natural gas flow to the burner assembly during the heating and ignition sequence.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features \u0026amp; Function\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eGenuine \u003cb\u003eLennox OEM\u003c\/b\u003e replacement component\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eCat #: 85K35\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003eModel \/ Part #: 85K3501\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003eNatural gas\u003c\/b\u003e application\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e24V\u003c\/b\u003e operation\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eDual direct ignition application\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003e3\/4\" inlet\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003e3\/4\" outlet\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eStandard-opening gas valve\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003e0.62A anticipator setting\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eControls natural gas flow to the burner assembly\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eDesigned for compatible Lennox gas heating equipment\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003eFurnace and commercial heating applications where specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Details \u0026amp; Key Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eBrand\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eLennox\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCatalog Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e85K35\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eModel \/ Part Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e85K3501\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProduct Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eGas Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eFuel Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eNatural Gas\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eVoltage\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e24V\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eIgnition Application\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDual Direct Ignition\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eInlet Size\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e3\/4\"\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eOutlet Size\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e3\/4\"\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eConnection Configuration\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e3\/4\" x 3\/4\"\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eOpening Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eStandard Opening\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 12;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eAnticipator Setting\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e0.62 A\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 13;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eFunction\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eBurner Gas Flow Control\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 14;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eApplication\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eGas Heating Equipment\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 15; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eOEM Component\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Segoe UI Emoji',sans-serif; mso-bidi-font-family: 'Segoe UI Emoji';\"\u003e🛠️\u003c\/span\u003e HVAC Depot Pro Tip\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eDo not match the \u003cb\u003e85K35 \/ 85K3501\u003c\/b\u003e based only on the \u003cb\u003e24V rating and 3\/4\" connections\u003c\/b\u003e. Gas valves with similar dimensions can have different ignition-control requirements, opening characteristics, electrical specifications, and fuel applications.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eVerify:\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCatalog Number: 85K35\u003c\/b\u003e\u003cbr\u003e\u003cb\u003ePart Number: 85K3501\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eFuel: Natural Gas\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eVoltage: 24V\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eIgnition: Dual Direct Ignition\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eConnections: 3\/4\" x 3\/4\"\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eOpening: Standard\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eAnticipator Setting: 0.62 A\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eGas-valve replacement should include leak testing, inlet and manifold gas-pressure verification, ignition testing, and combustion checks according to the equipment manufacturer's procedures and applicable codes.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEquipment \/ Model Compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eLennox 85K35 \/ 85K3501\u003c\/b\u003e is intended for select Lennox gas-fired heating equipment requiring this specific \u003cb\u003e24V dual direct ignition natural gas valve\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eTypical applications include:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eSelect Lennox gas furnaces\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eSelect Lennox commercial heating equipment\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eNatural-gas heating systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eDual direct ignition systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eEquipment requiring a \u003cb\u003e3\/4\" x 3\/4\"\u003c\/b\u003e gas valve\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eEquipment specifically calling for \u003cb\u003e85K35\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003eEquipment specifically calling for \u003cb\u003e85K3501\u003c\/b\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eAlways verify the complete equipment \u003cb\u003emodel and serial number\u003c\/b\u003e before ordering.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Lennox","offers":[{"title":"Default Title","offer_id":53977655083371,"sku":"66255116093","price":1238.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/85K35.jpg?v=1790964184"}],"url":"https:\/\/tophvacparts.com\/collections\/lennox-furnace-gas-valves-oem-gas-valve-replacement-parts.oembed?page=2","provider":"HVAC Parts and Equipment Depot Open To Homeowners and Contractors","version":"1.0","type":"link"}