{"title":"ICM Controls HVAC Circuit Boards","description":"\u003cp\u003e     Upgrade your HVAC system with high-performance \u003cstrong\u003eICM Controls Circuit Boards\u003c\/strong\u003e. Manufactured in the USA, ICM boards are the industry standard for reliable, cost-effective alternatives to expensive OEM furnace and air handler controls. Our inventory features top-rated models like the \u003cstrong\u003eICM2813 (Lennox SureLight replacement) and the ICM282B (Carrier Integrated Control)\u003c\/strong\u003e.\u003cbr\u003eWhether you need a gas ignition control, defrost board, or fan timer, ICM boards offer 'form, fit, and functional' compatibility. Get professional-grade reliability at a fraction of the OEM cost. \u003cstrong\u003eIn-stock and ready for same-day shipping\u003c\/strong\u003e\u003c\/p\u003e","products":[{"product_id":"carrier-furnace-control-boards","title":"ICM2807 Carrier 2 Stage Furnace Control Boards ICM2807\/HK42FZ017","description":"\u003ch1\u003eA Reliable Two-Stage Solution for Carrier, Bryant, \u0026amp; Payne Furnaces\u003c\/h1\u003e\n\u003cp\u003eIs your high-efficiency furnace locked out, or are you experiencing issues with multi-stage heating? The ICM2807 is a microprocessor-based furnace control board designed as a direct, form, fit, and functional replacement for Carrier, Bryant, and Payne control modules, specifically the HK42FZ017 series. This board manages all furnace operations with precision, handling two-stage heating and cooling demands. \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eWhy the ICM2807 is the Right Choice for Your Repair: \u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo-Stage Heating \u0026amp; Cooling: \u003c\/strong\u003eManages both low and high heat outputs (5A and 10A, respectively) and a powerful 10 HP cool blower motor, ensuring comfort and efficiency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Safety \u0026amp; Protection:\u003c\/strong\u003e Features a 100% gas shutoff safety feature, plus reverse polarity and secondary brownout voltage protection to safeguard sensitive components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Diagnostics:\u003c\/strong\u003e The onboard diagnostic LED provides clear fault codes, simplifying troubleshooting for issues like pressure switch trips or ignition failures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwinning Compatible: \u003c\/strong\u003eThe board is designed to communicate with another ICM2807 for synchronized operation in dual-furnace systems. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eComprehensive Cross-Reference Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ICM2807 is a direct functional replacement for the following part numbers Carrier \/ Bryant \/ Payne:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHK42FZ005\u003c\/li\u003e\n\u003cli\u003eHK42FZ010\u003c\/li\u003e\n\u003cli\u003eHK42FZ015\u003c\/li\u003e\n\u003cli\u003eHK42FZ016\u003c\/li\u003e\n\u003cli\u003eHK42FZ017 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eTECHNICAL SPECIFICATIONS:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient Temperature\u003c\/strong\u003e \u003cstrong\u003eOperating:\u003c\/strong\u003e -40°F to 176°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5% to 95% R.H. (non-condensing) @ +55°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e Line (98 to 132 VAC) @ 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnitor:\u003c\/strong\u003e 5A @ 120 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCool Blower:\u003c\/strong\u003e 10 HP, 120 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Heat:\u003c\/strong\u003e 5A, 1\/2 HP, 120 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Heat: \u003c\/strong\u003e10A, 1 HP, 120 VAC\u003c\/li\u003e\n\u003cli\u003eI\u003cstrong\u003enducer Motor:\u003c\/strong\u003e 4A, FLA-8.0 LRA @ 120 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Valve: \u003c\/strong\u003e1.5A @ 30 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAC: \u003c\/strong\u003e1A @ 120 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidifier:\u003c\/strong\u003e 0.5A \u0026amp; 24 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight: \u003c\/strong\u003e1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 1.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth: \u003c\/strong\u003e6.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength:\u003c\/strong\u003e 7\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003ePro-Tip: Check for a Two-Stage Thermostat\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003eThe ICM2807 is designed for a two-stage system. If you are replacing the board, ensure you are using a two-stage thermostat (which has W1 and W2 terminals) to get the full efficiency and comfort benefits of your furnace. A single-stage thermostat will only run the furnace in high heat mode.\u003c\/p\u003e","brand":"HVAC Parts and Equipment Depot","offers":[{"title":"Default Title","offer_id":52255933596011,"sku":null,"price":401.55,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/Carrier-1.webp?v=1754466476"},{"product_id":"icm280-furnace-control-goodman-b18099-xx-repalcement","title":"ICM280 Furnace Control Goodman B18099-xx Repalcement","description":"\u003cdiv class=\"details-div\"\u003e\n\u003cdiv class=\"summary entry-summary\"\u003e\n\u003ch1 class=\"product_meta\"\u003eGoodman OEM Replacement Board\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDETAILS:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLow cost form, fit and functional replacement board for Goodman, Janitrol, TI, White-Rodgers and UTEC\u003c\/li\u003e\n\u003cli\u003eMicroprocessor based design for precise timing\u003c\/li\u003e\n\u003cli\u003eFunctions with all 24 VAC thermostats\u003c\/li\u003e\n\u003cli\u003eDiagnostic fault codes (blinking LED) for simple troubleshooting\u003c\/li\u003e\n\u003cli\u003eTwinning compatible with another ICM280\u003c\/li\u003e\n\u003cli\u003eFor 80+ and 90+ applications\u003c\/li\u003e\n\u003cli\u003e9-pin card slot connection and 9-pin Molex connector on board\u003c\/li\u003e\n\u003cli\u003eUL recognized\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"weight-dimension-div\"\u003e\n\u003ch3\u003eWEIGHT\/DIMENSIONS:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWeight: 0.55\u003c\/li\u003e\n\u003cli\u003eHeight: 1\u003c\/li\u003e\n\u003cli\u003eWidth: 5.75\u003c\/li\u003e\n\u003cli\u003eLength: 4.75\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"weight-dimension-div\"\u003e\n\u003ch3\u003eSPECIFICATIONS:\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eLine Voltage Range: 98 to 132 VAC @ 60Hz\u003c\/p\u003e\n\u003cdiv\u003eIgnitor: 5A @ 120 VAC\u003c\/div\u003e\n\u003cdiv\u003eFan: 2 HP @ 240 VAC\u003c\/div\u003e\n\u003cdiv\u003eInducer Motor: 7A @ 250 VAC\u003c\/div\u003e\n\u003cdiv\u003eGas Valve: 1A @ 24 VAC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"additional-content-div\"\u003e\n\u003ch3\u003eREPLACES:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGoodman:\u003c\/strong\u003e B18099-06, B18099-08, B18099-10, B18099-13, B18099-13S\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUTEC:\u003c\/strong\u003e 1012-933D\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTexas Instruments:\u003c\/strong\u003e 41F-5\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhite-Rodgers:\u003c\/strong\u003e 50T35-730, 50T35-743\u003c\/p\u003e\n\u003c\/div\u003e","brand":"White-Rodgers","offers":[{"title":"Default Title","offer_id":52255937331563,"sku":null,"price":132.65,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/Goodman.webp?v=1754466581"},{"product_id":"icm-controls-icm2812-kit-replacement-board-white-rodgers-50m56u-843","title":"ICM Controls ICM2812-KIT Replacement Board | White-Rodgers 50M56U-843","description":"\u003cp\u003eStruggling with a failed furnace ignition or blower sequencer? The ICM2812-KIT is a heavy-duty, microprocessor-based Hot Surface Ignition (HSI) control module designed for ultimate versatility. This all-in-one kit includes a series of custom cable harnesses, allowing it to serve as a direct replacement for the White-Rodgers 50M56U-843 and more than 200 competitive part numbers across major brands like Carrier, Goodman, and Lennox. The ICM2812-KIT is a universal replacement board that comes packaged with a series of cable harnesses that make it a replacement for the White-Rodgers 50M56U-843 and more than 200 other popular part numbers! See the full cross reference information in the replaces section below.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eWhy the ICM2812-KIT is the Ultimate Repair Solution:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue Universal Compatibility: Includes various wiring adapters to replace over 200 OEM models without the need for complex splicing or rewiring.\u003c\/li\u003e\n\u003cli\u003eMicroprocessor Precision: Actively manages ignition timing, blower sequencing, and safety retries to ensure consistent heating and energy efficiency.\u003c\/li\u003e\n\u003cli\u003eAdvanced Safety Features: Features a 100% lockout safety system that immediately shuts off gas flow if ignition fails, plus continuous monitoring of limit, pressure, and rollout switches.\u003c\/li\u003e\n\u003cli\u003eDiagnostic Power: Built-in LED status and fault indicators display clear error codes, helping you pinpoint issues like flame-sense failure or safety-switch trips in seconds.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eUniversal Cross-Reference Guide:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThis universal kit is engineered to replace a massive range of HSI control boards, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhite-Rodgers:\u003c\/strong\u003e 50M56U-843 (Primary), 50A50 series, 50A55 series, 50A65 series, and 50M56-743.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHoneywell:\u003c\/strong\u003e S9200U1000.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMajor Brands:\u003c\/strong\u003e Replaces 200+ parts from Carrier, Bryant, Goodman, Lennox, Trane, York, and Nordyne.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage: \u003c\/strong\u003e24 VAC (18-30 VAC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Voltage:\u003c\/strong\u003e 120 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature: \u003c\/strong\u003e -40˚to 175˚F (-40˚to 80˚C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHSI Ignitor Output: \u003c\/strong\u003e 6.0 Amps @ 120 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower Relay Rating: \u003c\/strong\u003e 14.5 FLA @ 120 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Valve Output: \u003c\/strong\u003e1.5 Amps @ 24 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower Delays:\u003c\/strong\u003e Heat ON (30s) \/ Cool ON (6s) \/ Cool OFF (45s)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Weight: \u003c\/strong\u003e 4 lb.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength:\u003c\/strong\u003e 5.15 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 7.65 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 1.26 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eInstallation Tip:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe ICM2812-KIT is designed for ease, but always ensure the power is disconnected before starting. Use the included wire harness adapters specifically matched to your old board’s brand to ensure a secure, code-compliant connection without cutting wires.\u003c\/p\u003e","brand":"ICM","offers":[{"title":"Default Title","offer_id":52451503407467,"sku":"ICM2812-KIT","price":145.31,"currency_code":"USD","in_stock":false}]},{"product_id":"icm-icm280-oem-fan-control-board-goodman","title":"ICM280 Furnace Control Board | Goodman \u0026 Janitrol B1809913 Replacement | 9-Pin Connector","description":"\u003ch1\u003eMost Reliable Repair for Goodman \u0026amp; Janitrol 80+ and 90+ Furnace Control Boards:\u003c\/h1\u003e\n\u003cp\u003eIs your older furnace failing to trigger the ignition sequence? The ICM280 is a microprocessor-based replacement control board specifically engineered for Goodman, Janitrol, and White-Rodgers systems. Designed as a low-cost, form, fit, and functional alternative to expensive OEM parts, this board ensures your heating system operates with the precision of modern timing logic.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eWhy the ICM280 is the Preferred Replacement:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlug-and-Play Compatibility:\u003c\/strong\u003e Features the standard 9-pin card slot connection and an on-board 9-pin Molex connector for a seamless, wire-for-wire installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal System Support:\u003c\/strong\u003e Fully compatible with both 80+ and 90+ gas efficiency applications and works with all standard 24 VAC thermostats.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Safety Protocols:\u003c\/strong\u003e Includes a 100% gas shutoff safety feature that triggers automatically if the ignition sequence fails.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwinning Ready:\u003c\/strong\u003e This board is twinning compatible, allowing you to synchronize two furnace units to run on a single thermostat using a second ICM280.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuick Diagnostics:\u003c\/strong\u003e No more guessing—the integrated blinking LED provides diagnostic fault codes to help you pinpoint issues with pressure switches or flame sensors instantly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eComprehensive Cross-Reference Guide:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe ICM280 is a direct replacement for the following Goodman, UTEC, and White-Rodgers part numbers:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGoodman \/ Janitrol:\u003c\/strong\u003e B1809906, B1809908, B1809910, B1809913, B1809913S\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhite-Rodgers:\u003c\/strong\u003e 50T35-730, 50T35-743 (replaces 50T35 series)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTEC: \u003c\/strong\u003e1012-933D, 1012-933, 1012-930\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTexas Instruments (TI):\u003c\/strong\u003e 41F-5\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage:\u003c\/strong\u003e 24 VAC (18-30 VAC), 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Voltage:\u003c\/strong\u003e 115 VAC, 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnition Type:\u003c\/strong\u003e Hot Surface Ignition (HSI)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnections:\u003c\/strong\u003e 9-Pin Card Slot \u0026amp; 9-Pin Molex\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Feature:\u003c\/strong\u003e 100% Gas Shutoff Lockout\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e UL Recognized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Weight: \u003c\/strong\u003e4 LBS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight: \u003c\/strong\u003e1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 5.80\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength: \u003c\/strong\u003e4.50\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003ePro-Tip: Check the 9-Pin Edge Connector\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eWhen replacing an older Goodman board with the ICM280, inspect the female 9-pin edge connector on your furnace's wiring harness. Over time, these pins can become loose or corroded. For a reliable fix, use a small needle-nose tool to gently tighten the terminal tension before sliding it onto the new board's card slot. This ensures a solid electrical connection and prevents \"phantom\" fault codes caused by vibration.\u003c\/p\u003e","brand":"HVAC Depot","offers":[{"title":"Default Title","offer_id":52451503571307,"sku":"800442009223","price":152.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/original_45c5dcd1-5152-4c6d-8af3-9fb450fc9d3a.png?v=1760124262"},{"product_id":"icm282b-carrier-oem-replacement-furnace-control-hk42fz","title":"ICM282B Furnace Replacement Control Board | Carrier HK42FZ Direct Replacement","description":"\u003ch1\u003e\u003cstrong\u003eICM Controls ICM282B Furnace Control Board | Replaces Carrier HK42FZ Series\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp\u003eIs your furnace failing to ignite or experiencing blower motor issues? The ICM282B is a high-performance, microprocessor-based replacement board specifically engineered for Carrier, Bryant, and Payne fixed-speed furnaces. This American-made control module replaces the discontinued Carrier HK42FZ series, offering a cost-effective, plug-and-play repair solution. Fix your Carrier furnace fast with the ICM282B control board. Direct replacement for HK42FZ004, HK42FZ011, and more. Features diagnostic LEDs \u0026amp; easy 24V installation. Made in the USA.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eWhy the ICM282B is the Best Choice for Your Repair: \u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision Control:\u003c\/strong\u003e Manages the ignition sequence, gas valve, inducer motor, and blower speeds with microprocessor accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Troubleshooting: \u003c\/strong\u003eIntegrated diagnostic LED provides flash codes for common furnace faults (like flame rollout or limit switch lockouts), saving you hours in repair time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Protection: \u003c\/strong\u003eBuilt-in reverse polarity and secondary brownout protection safeguard your furnace's electrical system from power spikes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Twinning: \u003c\/strong\u003eFully compatible with twinned furnace setups, allowing two ICM282B boards to synchronize blower operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCarrier \u0026amp; Bryant Cross-Reference Guide\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eThis board is a direct, wire-for-wire replacement for the following OEM part numbers:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCarrier \/ Bryant \/ Payne: \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHK42FZ004, HK42FZ007, HK42FZ008, HK42FZ009, HK42FZ011, HK42FZ013, HK42FZ016, HK42FZ034\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eModel Codes: \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCEBD431012-01A, CEPL1311012-01, 325878-751\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFeature: \u003c\/strong\u003e Rating \/ Detail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 98-132 VAC @ 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnitor Output:\u003c\/strong\u003e 5A @ 120 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCool Blower:\u003c\/strong\u003e 10A @ 120 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat Blower:\u003c\/strong\u003e 5A @ 120 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInducer Motor: \u003c\/strong\u003e 4A @ 120 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Valve:\u003c\/strong\u003e 1.5A @ 24 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermostat: \u003c\/strong\u003e Compatible with standard 24 VAC thermostats\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eInstallation Tip:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eBefore removing your old Carrier board, take a photo of the wiring. The ICM282B includes a custom wiring harness adapter to ensure a secure fit for different HK42FZ configurations. Ensure the unit is powered off and grounded before installation to prevent electrostatic discharge (ESD)\u003c\/p\u003e","brand":"HVAC Depot","offers":[{"title":"Default Title","offer_id":52451503636843,"sku":"800442123271","price":261.92,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/original_faae0803-1f8d-4371-8522-d2449a52483f.png?v=1760124263"},{"product_id":"icm2813-furnace-control-board-lennox-surelight-replacement-replaces-10m9301-50a65-120","title":"ICM2813 Furnace Control Board | Lennox SureLight Replacement | Replaces 10M9301 \u0026 50A65-120","description":"\u003ch1\u003e\u003cstrong\u003eRestore Your Lennox Furnace Performance!\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp\u003eThe ICM2813 is a high-precision, microprocessor-based furnace control board designed as a form, fit, and functional replacement for the Lennox SureLight® Series and popular White-Rodgers equivalents. This American-made board manages every critical stage of your furnace's operation—from the inducer and pressure switches to the hot surface ignitor and blower motor—ensuring your home stays warm and safe all winter long.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eWhy the ICM2813 is the Professional’s Choice:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal System Monitoring:\u003c\/strong\u003e Actively manages the ignition sequence while maintaining 100% safety circuit monitoring, including high limit, rollout, and auxiliary limit switches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Precision:\u003c\/strong\u003e Features built-in diagnostic LEDs that flash specific fault codes, allowing you to quickly identify if the issue is a pressure switch, flame sense, or ignition failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable in Extreme Conditions:\u003c\/strong\u003e Rated for an operating temperature range of -40°F to 176°F, ensuring reliability in the coldest attics or hottest utility closets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-Speed Blower Support:\u003c\/strong\u003e Integrated relays for 2-speed (Heat\/Cool) blower motors and inducer draft motors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eComprehensive Cross-Reference Guide\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe ICM2813 is a direct replacement for the following Lennox and White-Rodgers part numbers:\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eLennox SureLight Series: \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e10M9301, 12L6901, 32M8801, 56L8401, 24L8501, 63K8901, 97L4801, 100925-01, 100925-03, 17W9201, 23W5101, 30W2501, 69M0801, 69M1501, 83M00.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eWhite-Rodgers: \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e50A65-120, 50A65-121, 50A62-120, 50A62-121, 50A62-820, 21D83M-843, 50A66-122, 50A66-123.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications: \u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 18-30 VAC, 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnitor Current:\u003c\/strong\u003e 2.0 Amp @ 80 VAC, 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInducer Relay:\u003c\/strong\u003e 2.2 FLA \/ 3.5 LRA @ 120 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower Relay:\u003c\/strong\u003e 9.5 FLA \/ 25.0 LRA @ 120 VAC (2-Speed)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Valve Relay:\u003c\/strong\u003e 1.5 Amp @ 25 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temp:\u003c\/strong\u003e -40°F to 176°F (-40°C to 80°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical rating:\u003c\/strong\u003e @ 77°F (25°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas valve relay:\u003c\/strong\u003e 1.5 amp @ 25 VAC, 60 Hz 0.6 pf\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HVAC Parts and Equipment Depot","offers":[{"title":"Default Title","offer_id":52741664440683,"sku":"ICM2813","price":0.0,"currency_code":"USD","in_stock":false}]},{"product_id":"icm2811-furnace-control-board-goodman-amana-pcbbf112-replacement-replaces-0130f00005","title":"ICM2811 Furnace Control Board | Goodman \u0026 Amana PCBBF112 Replacement | Replaces 0130F00005","description":"\u003ch1\u003e\u003cstrong\u003eReliable Control for Your Goodman or Amana Furnace\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp\u003eStop your furnace from blowing cold air or failing to ignite with the ICM2811. This American-made, microprocessor-based control board is a direct form, fit, and functional replacement for Goodman, Amana, and Janitrol OEM parts. Specifically designed for Hot Surface Ignition (HSI) systems, it manages the gas valve, inducer draft motor, and circulating blower with precision. \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eWhy the ICM2811 is the Smart Choice for Repairs: \u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect OEM Replacement: \u003c\/strong\u003eSeamlessly replaces common Goodman part numbers like PCBBF112, PCBBF123, and 0130F00005.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Diagnostics: \u003c\/strong\u003eFeatures a built-in diagnostic LED that illuminates specific flash codes, allowing you or a technician to troubleshoot pressure switches, limit switches, or flame sense issues in seconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety \u0026amp; Reliability:\u003c\/strong\u003e Includes a 100% gas shutoff feature in case of ignition failure and integrated reverse polarity protection to safeguard your system's electronics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwinning Compatible: \u003c\/strong\u003eReady for dual-furnace setups, this board can be twinned with another ICM2811 to synchronize blower operation across two units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eGoodman \u0026amp; White-Rodgers Cross-Reference:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThis board is a wire-for-wire replacement for the following part numbers:\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGoodman \/ Amana \/ Janitrol: \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePCBBF110\u003c\/li\u003e\n\u003cli\u003ePCBBF110S\u003c\/li\u003e\n\u003cli\u003ePCBBF112\u003c\/li\u003e\n\u003cli\u003ePCBBF112S\u003c\/li\u003e\n\u003cli\u003ePCBBF123\u003c\/li\u003e\n\u003cli\u003ePCBBF123S\u003c\/li\u003e\n\u003cli\u003e0130F00005\u003c\/li\u003e\n\u003cli\u003e0130F00005S\u003c\/li\u003e\n\u003cli\u003eB18099-26\u003c\/li\u003e\n\u003cli\u003eB18099-26S\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eWhite-Rodgers:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e50A55-743\u003c\/li\u003e\n\u003cli\u003e50A55-289\u003c\/li\u003e\n\u003cli\u003e50T55-289\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage:\u003c\/strong\u003e 18-30 VAC, 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnitor Current:\u003c\/strong\u003e 6.0 Amp @ 120 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInducer Relay:\u003c\/strong\u003e 2.2 FLA \/ 3.5 LRA @ 120 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower Relay: \u003c\/strong\u003e14.5 FLA \/ 25.0 LRA @ 120 VAC (2-Speed)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Valve Relay:\u003c\/strong\u003e 1.5 Amp @ 25 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temp:\u003c\/strong\u003e -40°F to 176°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage: \u003c\/strong\u003e120 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range:\u003c\/strong\u003e 5 to 95% relative humidity (non-condensing)\u003c\/li\u003e\n\u003cli\u003eElectrical Ratings were made at 77°F (25°C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003ePro-Tip: Solve the \"No Ignition\" Mystery\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eWhen installing the ICM2811, ensure your furnace has a solid, clean ground connection. Because this board uses a microprocessor for \"Flame Sensing,\" a weak ground is the #1 reason for a \"No Flame Detected\" fault code—even if your ignitor is glowing. Before finalizing your install, take a piece of steel wool or sandpaper to the ground screw area to ensure metal-to-metal contact. This small step often solves intermittent ignition failures that look like a \"bad board\" but are actually just a ground loop issue!\u003c\/p\u003e","brand":"HVAC Parts and Equipment Depot","offers":[{"title":"Default Title","offer_id":52743563182443,"sku":"ICM2811","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/ICM2811.jpg?v=1769200521"},{"product_id":"icm280-furnace-control-board-goodman-janitrol-b1809913-replacement-9-pin-connector-copy","title":"ICM2810 Furnace Control Board | Goodman \u0026 Amana B1809926 Replacement | Replaces PCBBF101S","description":"\u003ch1\u003eICM2810 Furnace Control Board | Goodman \u0026amp; Amana B1809926 Replacement | Replaces PCBBF101S\u003c\/h1\u003e\n\u003cp\u003eGoodman, Amana, and Janitrol furnaces that use a single-stage, Hot Surface Ignition (HSI) system. This board is a \"gold standard\" for DIY repairs because of its simple layout and direct 9-pin compatibility.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eRestore Reliability to Your Goodman or Amana Heating System\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eIs your furnace failing to kick on, or is the blower motor acting inconsistently? The ICM2810 is a microprocessor-based furnace control board designed as a high-quality, low-cost replacement for Goodman, Amana, and Janitrol OEM controls. This American-made board manages the ignition sequence, gas valve, and blower functions with modernized precision, ensuring your furnace operates safely and efficiently.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eWhy the ICM2810 is the Best Choice for Your Repair:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect Wire-for-Wire Replacement: \u003c\/strong\u003eSpecifically engineered to replace the Goodman B1809926 and PCBBF101 series, making installation straightforward for homeowners and technicians alike.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision Microprocessor Timing: \u003c\/strong\u003eEliminates the \"drift\" found in older analog boards, providing accurate timing for the inducer, ignitor, and blower cycles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstant Diagnostics: \u003c\/strong\u003eFeatures an onboard diagnostic LED that flashes clear fault codes. No more guessing—quickly identify if the problem is a pressure switch, limit switch, or flame sensor issue.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Safety Protection: \u003c\/strong\u003eBuilt with a 100% gas shutoff safety feature and reverse polarity protection to safeguard your furnace's internal electronics from wiring errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal System Support: \u003c\/strong\u003eWorks with all standard 24 VAC thermostats and supports both 80+ and 90+ AFUE gas furnace applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eComprehensive Cross-Reference Guide:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe ICM2810 is a direct functional replacement for the following part numbers:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eGoodman \/ Amana \/ Janitrol: \u003c\/strong\u003e\u003c\/h3\u003e\nB1809926, B1809926S, PCBBF101, PCBBF101S, PCBBF103, PCBBF103S, 0130F00004, 0130F00004S.\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eWhite-Rodgers:\u003c\/strong\u003e\u003c\/h3\u003e\n50A55-250, 50A55-743.\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eUTEC: \u003c\/strong\u003e\u003c\/h3\u003e\n1012-933D.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage: \u003c\/strong\u003e24 VAC (18-30 VAC), 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Voltage:\u003c\/strong\u003e 115 VAC, 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnition Type: \u003c\/strong\u003eHot Surface Ignition (HSI)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnitor Current:\u003c\/strong\u003e 6.0 Amp @ 120 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower Relay: \u003c\/strong\u003e14.5 FLA \/ 25.0 LRA @ 120 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Features:\u003c\/strong\u003e 100% Gas Shutoff \u0026amp; Reverse Polarity Protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003ePro-Tip: The \"Click\" Test: \u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eWhen you first power up your new ICM2810, listen for the distinct \"click\" of the relays. If the board receives power but you don't hear a click within 30 seconds of a heat call, check your Door Switch. A loose or bypassed furnace blower door can prevent the 120V line from reaching the board, making it look like a \"dead board\" when it’s actually a safety interlock issue.\u003c\/p\u003e","brand":"HVAC Depot","offers":[{"title":"Default Title","offer_id":52743622230379,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}]},{"product_id":"icm2810-furnace-control-board-goodman-amana-b1809926-replacement-replaces-pcbbf101s-copy","title":"ICM291 Two-Speed Furnace Control Board – Replacement for ICP 1171166 \u0026 Carrier 1010738","description":"\u003ch1\u003eA Reliable 2-Speed Solution for ICP  International Comfort Products Furnaces:\u003c\/h1\u003e\n\u003cp\u003eIs your high-efficiency furnace experiencing ignition lockouts or blower motor failures? The ICM291 is a robust, microprocessor-based control board designed as a direct, form, fit, and functional replacement for specific Carrier, Bryant, and Payne DSI (Direct Spark Ignition) systems operating on 208\/230 VAC line voltage. This USA-made board manages all aspects of your system, including the two-speed blower motors and spark ignitor, ensuring safe and efficient operation. ICM 291 also monitors for safety issues like flame sensing and lockout. It features a status LED for fault diagnostics and is compatible with both natural and LP gas. \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eWhy the ICM291 is the Right Choice for Your Repair: \u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDSI Technology:\u003c\/strong\u003e Manages the entire Direct Spark Ignition sequence, from pre-purge timing to flame sensing and lockout monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Voltage Support:\u003c\/strong\u003e Designed specifically for 208\/230 VAC line voltage applications (not 115V systems).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo-Speed Motor Control:\u003c\/strong\u003e Features dedicated outputs for both heating (low speed) and cooling (high speed) blower motors, as well as the combustion motor hall effect sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Diagnostics:\u003c\/strong\u003e An onboard status LED provides clear, flashing fault codes to simplify troubleshooting and maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e100% Safety Lockout:\u003c\/strong\u003e Includes a robust 100% gas shutoff safety feature and manual reset lockout to prevent hazardous conditions. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eComprehensive Cross-Reference Guide\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe ICM291 is a direct functional replacement for the following part numbers: \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCarrier \/ Bryant \/ Payne: \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLH33WP003A\u003c\/li\u003e\n\u003cli\u003eLH33WP003 \u003c\/li\u003e\n\u003cli\u003e1171166\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnition Type:\u003c\/strong\u003e Direct Spark Ignition (DSI)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Voltage:\u003c\/strong\u003e 208\/230 VAC, 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage:\u003c\/strong\u003e 24 VAC (18-30 VAC), 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-Purge Time: \u003c\/strong\u003e45 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrial for Ignition:\u003c\/strong\u003e 5 seconds ignition activation, 2 seconds flame establishing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePost-Purge Time:\u003c\/strong\u003e 45 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetry Period: \u003c\/strong\u003eEvery 20 seconds for 15 minutes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLockout: \u003c\/strong\u003eManual reset\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePost-Purge:\u003c\/strong\u003e 45 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower: \u003c\/strong\u003eRT and C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermostat Interface:\u003c\/strong\u003e R,W, and G\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Switches:\u003c\/strong\u003e RS, LS, and CS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temp:\u003c\/strong\u003e -40°F to 176°F (-40°C to 75°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e 3.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 1.875\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth: \u003c\/strong\u003e7\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength: \u003c\/strong\u003e5\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003ePro-Tip: Verify Your Voltage First\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eBefore purchasing the ICM291, look at the wiring diagram inside your furnace access panel to confirm you have 208\/230 VAC coming in. Installing this board in a standard 115 VAC system will cause immediate failure. This board is specifically for DSI (Direct Spark Ignition) Carrier systems that use higher line voltage.\u003c\/p\u003e\n\u003ch2\u003eCross-Reference \u0026amp; Compatibility \u003c\/h2\u003e\n\u003cp\u003eThe ICM291 is a direct functional replacement for the following part numbers\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarrier \/ Bryant \/ Payne: \u003c\/strong\u003eLH33WP003, LH33WP003A\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eICP (Heil \/ Tempstar \/ Comfortmaker):\u003c\/strong\u003e 1171166\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGoodman \/ Amana:\u003c\/strong\u003e 0130F00005S\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRheem \/ Ruud:\u003c\/strong\u003e 62-24140-04\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"HVAC Depot","offers":[{"title":"Default Title","offer_id":52743632126315,"sku":"ICM291-LH33WP003A","price":295.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/ICP291_bb05b058-dc3e-498a-80d3-1761c56598a5.jpg?v=1769808593"},{"product_id":"icm291-two-speed-furnace-control-board-carrier-lh33wp003a-replacement-208-230-vac-copy-copy","title":"ICM289 Furnace Control Board | Lennox BCC1, BCC2, BCC3 Replacement | Replaces 48K98 \u0026 45K48","description":"\u003ch1\u003eICM 289 Is A Perfect Fit for Your Older Lennox, Armstrong, or AirEase Furnace\u003c\/h1\u003e\n\u003cp\u003eIs your Lennox furnace experiencing control board failure, indicated by no heat or intermittent blower function? The ICM289 is a microprocessor-based control board engineered as a low-cost, form, fit, and functional replacement for the entire Lennox BCC1, BCC2, and BCC3 series circuit boards. This American-made board provides precise control over the inducer fan motor, blower fan, and monitors essential safety limit switches. \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eWhy the ICM289 is the Smart Choice for Repairs: \u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal Lennox Compatibility:\u003c\/strong\u003e Replaces all variations of the BCC1, BCC2, and BCC3 boards, including specific part numbers like 48K98 and 45K48, ensuring a seamless installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision Timing Logic:\u003c\/strong\u003e Utilizes a microprocessor design to manage all system timing, including a 45-second heat blower ON delay and selectable OFF delays.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Capacity Blower Support:\u003c\/strong\u003e Features heavy-duty 20 Amp relays for both heat and cool blower functions, ensuring reliable power delivery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Voltage Range: \u003c\/strong\u003eDesigned to operate reliably within a line voltage range of 98-132 VAC, accommodating minor fluctuations in power supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Thermostat Functionality: \u003c\/strong\u003eWorks seamlessly with all standard 24 VAC thermostats. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eComprehensive Cross-Reference Guide:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe ICM289 replaces all BCC1, BCC2, and BCC3 circuit boards and is a direct functional replacement for the following Lennox\/OEM part numbers: \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLennox: All \u003c\/strong\u003eBCC1, BCC2, BCC3 circuit boards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLennox Specific P\/Ns: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e48K98\u003c\/li\u003e\n\u003cli\u003e48K9801\u003c\/li\u003e\n\u003cli\u003e45K48\u003c\/li\u003e\n\u003cli\u003e45K4801\u003c\/li\u003e\n\u003cli\u003e35K77\u003c\/li\u003e\n\u003cli\u003e35K7701\u003c\/li\u003e\n\u003cli\u003e65K29\u003c\/li\u003e\n\u003cli\u003e65K2901\u003c\/li\u003e\n\u003cli\u003e78J61\u003c\/li\u003e\n\u003cli\u003e78J6101\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eLennox Obsolete P\/Ns:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLB-53622A\u003c\/li\u003e\n\u003cli\u003eLB-90089A\u003c\/li\u003e\n\u003cli\u003eLB-87086A\u003c\/li\u003e\n\u003cli\u003eLB-63622AA\u003c\/li\u003e\n\u003cli\u003eLB-90676A\u003c\/li\u003e\n\u003cli\u003e40L8801\u003c\/li\u003e\n\u003cli\u003e30H6701\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Voltage: \u003c\/strong\u003eRange 98–132 VAC @ 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage:\u003c\/strong\u003e 24 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat\/Cool Blower:\u003c\/strong\u003e 20A @ 120 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInducer Motor: \u003c\/strong\u003e5A @ 120 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat Blower On Delay: \u003c\/strong\u003e45 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat Blower Off Delay:\u003c\/strong\u003e 90, 150, 210, or 270 seconds (selectable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight: \u003c\/strong\u003e0.35\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 5.625\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength:\u003c\/strong\u003e 4.25\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\n\u003cstrong\u003ePro-Tip: Check the Blower Speed Taps                                                                                      \u003c\/strong\u003eThe ICM289 manages various time delays. When installing this board, always confirm the correct speed tap connections on the board's terminals (e.g., HEAT, COOL, FAN) match your furnace's wiring diagram. Incorrect speed settings are a primary source of airflow issues and can cause limit switch trips shortly after startup. \u003c\/h4\u003e","brand":"HVAC Depot","offers":[{"title":"Default Title","offer_id":52754961006955,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}]},{"product_id":"icm2807-carrier-2-stage-furnace-control-boards-icm2807-hk42fz017-copy","title":"ICM2805A Furnace Control Board | Nordyne 903106 \u0026 624631 Replacement | 2 HP Blower Support","description":"\u003ch1\u003e\u003cstrong\u003eICM2805A Furnace Control Board – USA Made Replacement for Nordyne 624631 \u0026amp; 903106\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e     The\u003cstrong\u003e ICM2805A \u003c\/strong\u003eis a high-performance, microprocessor-based \u003cstrong\u003efurnace control board\u003c\/strong\u003e designed by ICM Controls as a\u003cstrong\u003e direct form, fit, and functional replacement for Nordyne, Miller, and Intertherm 903106 and 624631\u003c\/strong\u003e series controls. This USA-made board is engineered for maximum reliability in G3, G4, G5, G6, M2, and M3 furnace modules, providing a professional-grade alternative to expensive OEM parts.\u003c\/p\u003e\n\u003cp\u003e     Designed to actively manage the gas valve, inducer draft motor, hot surface ignitor, and circulating blower, the ICM2805A features advanced diagnostic LEDs to simplify troubleshooting. Whether you are dealing with a \"no-heat\" call or an intermittent ignition failure, this board offers the precision and safety required to restore your system to peak performance.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features and Function:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy-Duty Power Handling:\u003c\/strong\u003e Features a high-capacity cool blower relay rated for 2 HP motors (10A @ 240 VAC) for demanding applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Diagnostics:\u003c\/strong\u003e Onboard LEDs provide clear flash codes to identify issues like brownout voltage, flame faults, or ignition failures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First:\u003c\/strong\u003e Monitored by a microprocessor with a 100% gas shutoff safety lockout if ignition is not established.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwinning Capable:\u003c\/strong\u003e Fully compatible with standard 24 VAC thermostats and supports twinning with a second ICM2805A for dual-furnace setups.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Details and Key Specifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e ICM2805A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ICM Controls (Made in the USA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 120\/240 VAC @ 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnitor:\u003c\/strong\u003e 5A @ 120 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCool Blower\u003c\/strong\u003e: 10A, 2HP @ 240 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInducer Blower:\u003c\/strong\u003e 4A @ 120 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Valve:\u003c\/strong\u003e 1A @ 24 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 6” L x 4.5” W x 1.5” H\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e 2.5 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e🛠️ HVAC Depot Pro Tip: Correcting \"Phantom\" Brownout Codes\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eIf your ICM2805A shows a 6-flash \"Brownout\" code, it might not be a utility grid issue. Check your furnace transformer output. If the 24V side dips below 18VAC when the gas valve or inducer kicks on, the board will signal a brownout. Replacing a weak 24V Transformer often clears this code and prevents unnecessary system lockouts.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCross-Reference \u0026amp; Compatibility:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe ICM2805A is a direct replacement for a massive range of Nordyne-family part numbers:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eNordyne \/ Miller \/ Intertherm: \u003c\/strong\u003e\u003c\/h3\u003e\n903106, 903106-Kit, 624631, 624631-A, 624631-B, 624591 (A\/B\/C\/D), 6245640, 1012-955A\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eCarrier: \u003c\/strong\u003e\u003c\/h3\u003e\nHK42FZ011, HK42FZ013, HK42FZ0-xx series\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HVAC Parts and Equipment Depot","offers":[{"title":"Default Title","offer_id":52755202212203,"sku":"ICM2805A","price":0.0,"currency_code":"USD","in_stock":false}]},{"product_id":"icm255-rheem-fan-blower-control-oem-fixed-delay-timer","title":"ICM255C Rheem Fan Blower Control | OEM Fixed Delay Timer","description":"\u003ch1\u003eICM255C – Genuine OEM Fan Blower Control (Dual On\/Off Delay Timer, Fixed Time Delay)\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eICM ICM255C\u003c\/strong\u003e is a Genuine Original Equipment Manufacturer (OEM) dual-function fan delay timer in an open board design. It is engineered to control the circulating fan in heat pump, air conditioning, and forced air systems. This control ensures optimal comfort levels by providing a one-second on-delay to allow air to reach proper temperature before energizing the fan, and a fixed sixty-second off-delay to purge ducts of residual air, thereby increasing energy efficiency.\u003c\/p\u003e\n\u003cp\u003eAs an authentic OEM equivalent component, the ICM255C ensures reliable performance with a low-cost, open board design and high-power relay output. It operates on a standard 24 VAC control voltage (18 to 30 VAC input range) and is compatible with a wide range of residential and commercial HVAC equipment models, serving as a direct wire-for-wire replacement for many OEM control boards.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features and Function:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Function Timer:\u003c\/strong\u003e Offers a 1-second on and 60-second off delay for heating and cooling cycles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenuine OEM Quality:\u003c\/strong\u003e Meets or exceeds original manufacturer specifications for reliable timing and performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy Efficiency:\u003c\/strong\u003e The 60-second off-delay clears ducts of residual conditioned air, increasing system efficiency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Compatibility:\u003c\/strong\u003e Works with various HVAC models, including A-1, Bard, Mars, Rheem, and Snyder General\/ICP systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Details and Key Specifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e ICM255C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ICM Controls\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Type:\u003c\/strong\u003e Fan Blower Control \/ Fan Delay Timer\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage:\u003c\/strong\u003e 24 VAC (18-30 VAC input range)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e 4 LB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTiming Range:\u003c\/strong\u003e 1-second ON delay; 60-second OFF delay (Fixed)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage Rating:\u003c\/strong\u003e 20 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 2.5 in L x 2.5 in W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Open board design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e🛠️ HVAC Depot Pro Tip: Diagnosing Noisy Airflow\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eIf the \"On Delay\" function is faulty, the system may produce cold air at startup during heating mode. If the fan shuts off immediately after the compressor stops cooling, the \"Off Delay\" function is likely the issue, resulting in wasted conditioned air. Test the function by ensuring the fan engages after a 1-second delay during heating and runs for exactly 60 seconds after the thermostat satisfies the call for heat.\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003eCross-Reference:\u003c\/strong\u003e \u003c\/h2\u003e\n\u003cp\u003eThe ICM255C is a replacement for these OEM part numbers:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM \u0026amp; Catalog Numbers:\u003c\/strong\u003e ICM255C, ICM255, 8201-056 (Bard), 1395336 (Snyder General\/ICP).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand Specific Replacements:\u003c\/strong\u003e Rheem 42-22515-01, 42-22515-02, 42-22515-03, 42-22515-04, Mars 32574.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"ICM","offers":[{"title":"Default Title","offer_id":52929152483691,"sku":"ICM255C","price":49.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/ICM255c.jpg?v=1771607722"},{"product_id":"icm271c-fan-blower-control-oem-replacement-for-carrier-hh84aa020","title":"ICM271C Fan Blower Control - OEM Replacement for Carrier HH84AA020","description":"\u003ch1\u003eICM P\/N ICM271C – Genuine OEM Fan Blower Control (Dual On\/Off Delay Timer, Direct OEM Replacement)\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eICM ICM271C\u003c\/strong\u003e (SKU: ICM271C) is a Genuine Original Equipment Manufacturer (OEM) dual-function fan delay timer designed as a direct replacement for thousands of specific OEM furnace control boards. It is engineered to control the circulating fan in heat pump, air conditioning, and forced air systems. This advanced control module provides precise fan management, ensuring optimal comfort by delaying the fan's start and end times to maximize energy efficiency and prevent the initial blast of unconditioned air.\u003c\/p\u003e\n\u003cp\u003eAs an authentic OEM equivalent component, the ICM271C ensures reliable performance with a low-cost, open board design and high-power relay output (10A N.O. 10A N.C.). It operates on a standard 24 VAC control voltage and is compatible with a wide range of residential and commercial HVAC equipment models, often serving as a universal yet specific wire-for-wire replacement for many proprietary boards.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features and Function:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Function Timer:\u003c\/strong\u003e Provides customizable ON and OFF delays for heating and cooling cycles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenuine OEM Quality:\u003c\/strong\u003e Meets or exceeds original manufacturer specifications for reliable timing and performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Potentiometers:\u003c\/strong\u003e Features adjustable ON\/OFF delay times via onboard potentiometers for precise field calibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal Application:\u003c\/strong\u003e Direct replacement for thousands of universal 24V timing boards across various brands.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Details and Key Specifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e ICM271C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSKU:\u003c\/strong\u003e ICM271C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ICM Controls\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Type:\u003c\/strong\u003e Fan Blower Control \/ Fan Delay Timer \/ Universal Timing Board\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage:\u003c\/strong\u003e 24 VAC (18-30 VAC input range)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTiming Range:\u003c\/strong\u003e Adjustable (Typically 1s-10s ON, 30s-120s OFF delay)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage Rating:\u003c\/strong\u003e 10 A N.O., 10 A N.C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 2.75 in L x 3 in W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e🛠️ HVAC Depot Pro Tip: Calibrating the Delay Timers\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe main advantage of the ICM271C is its adjustable delays via the built-in potentiometers (the small adjustment knobs). A typical heating cycle requires an \"ON\" delay of around 30 seconds to allow the heat exchanger to warm up, while a \"COOLING\" off delay should be adjusted to clear the ducts of residual cool air without making the blower run excessively long. Ensure you consult your furnace or air handler manual for the \u003cem\u003eexact\u003c\/em\u003e recommended timing settings to optimize your system's efficiency and comfort level.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCross-Reference:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe ICM271C is a widely compatible replacement for numerous OEM and universal part numbers:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM \u0026amp; Catalog Numbers:\u003c\/strong\u003e ICM271C, ICM271, 331405 (ICP\/Snyder General), 42-22515-05 (Rheem).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Cross:\u003c\/strong\u003e Mars 32575, Supco TD68, White-Rodgers 90-293.\u003c\/li\u003e\n\u003cli\u003eCarrier CES0110017, CESO110018, 302075-3, P771-7002, HH84AA010, HH84AA012, HH84AA013, HH84AA030\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eExtensive Model Compatibility List:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cem\u003eNote: This is a universal component used with various systems based on control voltage and timing requirements.\u003c\/em\u003e\u003c\/p\u003e","brand":"ICM","offers":[{"title":"Default Title","offer_id":52929188561259,"sku":"ICM271C","price":65.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/ICM217C.jpg?v=1771608499"}],"url":"https:\/\/tophvacparts.com\/collections\/icm-control-boards.oembed","provider":"HVAC Parts and Equipment Depot","version":"1.0","type":"link"}