{"title":"Furnace Pressure Switch","description":"","products":[{"product_id":"carrier-318984-753-inducer-motor-kit-1-25-hp-115v-3300-rpm","title":"Carrier 318984-753 | Inducer Motor Kit | 1\/25 HP | 115V | 3300 RPM","description":"\u003ch1\u003e\u003cstrong\u003eCarrier 318984-753 Inducer Motor Kit 1\/25 HP 115V 3300 RPM Draft Inducer Blower\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe Carrier \u003cstrong\u003e318984\u003c\/strong\u003e-\u003cstrong\u003e753 \u003c\/strong\u003eInducer Motor Kit is a high-performance \u003cstrong\u003eOEM replacement \u003c\/strong\u003edesigned to serve as the critical \"exhaust brain\" of your heating system. This motor is responsible for the pre-purge cycle, drawing combustion air into the burners and venting toxic flue gases safely out of the heat exchanger. Specifically \u003cstrong\u003eengineered for \u003c\/strong\u003ethe \u003cstrong\u003eCarrier\u003c\/strong\u003e, \u003cstrong\u003eBryant\u003c\/strong\u003e, and \u003cstrong\u003ePayne \u003c\/strong\u003e340, 350, 352, and 355 furnace series, this kit ensures that the pressure switch is properly engaged to allow the ignition sequence to begin, maintaining both system efficiency and home safety.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision OEM Part Number: \u003c\/strong\u003eSpecifically engineered as the direct replacement for 318984-753, ensuring the mounting bracket and electrical leads align perfectly with factory specifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAcoustically Balanced Operation:\u003c\/strong\u003e Built to eliminate the high-pitched \"whine\" or grinding noises common in failing legacy motors, restoring quiet operation to your mechanical room.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Safety Monitoring:\u003c\/strong\u003e Works in tandem with the furnace's pressure switch to ensure the vent remains clear, automatically shutting down the gas valve if an obstruction is detected.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurability-Focused Construction: \u003c\/strong\u003eFeatures a high-grade 1\/25 HP motor designed for high-heat environments, preventing premature bearing failure caused by flue gas temperatures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeamless Ignition Flow: \u003c\/strong\u003eProvides the consistent 3300 RPM airflow required to clear the combustion chamber, ensuring a smooth and reliable \"first-time\" ignition every cycle.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Details\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Carrier \/ Bryant \/ Payne\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer: \u003c\/strong\u003eUnited Technologies \/ Jakel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart #: \u003c\/strong\u003e318984-753\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC\/SKU: \u003c\/strong\u003e662442035639 \/ 318984-753-KIT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Weight: \u003c\/strong\u003e5 Pounds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 115 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmps:\u003c\/strong\u003e 0.70 Amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRPM: \u003c\/strong\u003e3300 RPM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHorsepower:\u003c\/strong\u003e 1\/25 HP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnition Type:\u003c\/strong\u003e Compatible with Hot Surface Ignition (HSI) and Spark Ignition Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e🛠️ HVAC Depot Pro Tip\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eTake a Picture First! Before removing the old assembly, photograph the orientation of the motor and the specific routing of the pressure switch tubing. If the new inducer is rotated even 45 degrees incorrectly, the condensate drain port or pressure tap may not align with your existing setup. Diagnostic Check: After installing, check the \"drain tap\" for any debris; a clogged inducer port is the #1 cause of a \"Pressure Switch Stuck Open\" fault code, even with a brand-new motor.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCross-Reference\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eSuperseded \/ Legacy:\u003c\/strong\u003e\u003c\/h3\u003e\n318984-751, 318984-752, 310371-751, 310371-752, 310371-753\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eDrawing Numbers:\u003c\/strong\u003e\u003c\/h3\u003e\nJ238-150-1533, J238-150-15124\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eOther Identifiers:\u003c\/strong\u003e\u003c\/h3\u003e\nHC21ZE117, P271-753\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eModel Compatibility\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e340 Series \u003c\/strong\u003e(Suffixes: MAV, JAV)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e350 Series\u003c\/strong\u003e (Suffixes: MAV, JAV)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e352 Series\u003c\/strong\u003e (Suffixes: MAV)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e355 Series\u003c\/strong\u003e (Suffixes: MAV, JAV, MCV)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e58M Series \u003c\/strong\u003e(Suffixes: MXA, MXB, MCB, MCV)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e921 Series\u003c\/strong\u003e (Suffixes: S, T)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Carrier","offers":[{"title":"Default Title","offer_id":52235520246123,"sku":"318984-753","price":422.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/rcdparts_318984-753_article_1411645331217_en_normal.webp?v=1753876442"},{"product_id":"protech-70-23641-86-induced-draft-blower-includes-gasket-115v-3000-rpm-0-7-amp","title":"PROTECH 70-23641-86 Induced Draft Blower | Includes Gasket | 115V 3000 RPM 0.7 Amp","description":"\u003ch1\u003ePROTECH 70-23641-86 Induced Draft Blower | Includes Gasket | 115V 3000 RPM 0.7 Amp\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003e70-23641-86\u003c\/strong\u003e is a precision-engineered OEM Induced Draft Blower assembly designed to serve as the critical \"exhaust system\" for Rheem and Ruud gas furnaces. This assembly functions as the primary \"brain\" for combustion safety, pulling air through the heat exchanger to ensure a proper fuel-to-air mixture before the ignition cycle begins. Specifically optimized for the \u003cstrong\u003eRGRM, RGRA, and RGLQ\u003c\/strong\u003e series, this factory-authorized PROTECH™ part maintains the negative pressure required to close the furnace pressure switch. Replacing a failing inducer with this genuine kit fixes specific \"no-heat\" lockout issues and eliminates the high-pitched \"bearing squeal\" often found in aging motors, ensuring your system operates at peak 80% to 90%+ AFUE efficiency.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete OEM Kit:\u003c\/strong\u003e The \u003cstrong\u003e70-23641-86\u003c\/strong\u003e is a direct factory replacement that includes a high-temperature \u003cstrong\u003efiber gasket\u003c\/strong\u003e, ensuring a gas-tight seal against the collector box without the need for messy RTV silicone.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision RPM Calibration:\u003c\/strong\u003e Factory-rated at \u003cstrong\u003e3000 RPM\u003c\/strong\u003e, providing the exact static pressure needed to satisfy safety switches and prevent \"pressure switch open\" fault codes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolved Noise \u0026amp; Vibration:\u003c\/strong\u003e Features a dynamically balanced cooling fan and high-grade internal bearings to fix specific mechanical humming or rattling issues common in older inducer housings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Monitoring Integration:\u003c\/strong\u003e Engineered to work seamlessly with the furnace's limit circuit, providing constant airflow to purge the heat exchanger of residual gases before and after each heating cycle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Corrosion-Resistant Housing:\u003c\/strong\u003e Constructed from heavy-duty materials to withstand the acidic condensate and high-heat environment of a modern furnace exhaust path.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Details\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e PROTECH™ (Rheem \/ Ruud \/ WeatherKing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Rheem Manufacturing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 70-23641-86\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 5.5 lbs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 115 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent:\u003c\/strong\u003e 0.7 Amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpeed:\u003c\/strong\u003e 3000 RPM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Type:\u003c\/strong\u003e Shaded Pole\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncludes:\u003c\/strong\u003e Inducer Motor, Blower Wheel, Housing, and Gasket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e🛠️ HVAC Depot Pro Tip\u003c\/h2\u003e\n\u003cp\u003eBefore removing your old draft blower, \u003cstrong\u003etake a high-resolution picture of the wiring and the vacuum hose connections.\u003c\/strong\u003e For the \u003cstrong\u003e70-23641-86\u003c\/strong\u003e to work correctly, the small rubber pressure switch tubing must be free of cracks and seated tightly on the new housing's nipple. When installing, ensure the old gasket material is completely scraped off the furnace's metal surface to prevent exhaust leaks. After installation, cycle the furnace and watch the pressure switch to verify it closes within seconds of the motor reaching full speed.\u003c\/p\u003e\n\u003ch2\u003eCross-Reference\u003c\/h2\u003e\n\u003cp\u003eThis inducer assembly is a direct replacement or equivalent for the following legacy and manufacturer part numbers:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuperseded Parts:\u003c\/strong\u003e 70-23641-01, 70-21496-01, 70-21504-01\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLegacy Numbers:\u003c\/strong\u003e J238-112-11116, FB-RFB547\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrawing Numbers:\u003c\/strong\u003e 11708, 3110-3343\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhite-Rodgers\/Emerson Equivalents:\u003c\/strong\u003e Fasco A143, Jakel 11708\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eModel Compatibility\u003c\/h2\u003e\n\u003cp\u003eThis inducer is compatible with various 80% and 90% AFUE furnaces. Grouped by base model:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRheem \/ Ruud RGR Series\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRGRM\u003c\/strong\u003e (Suffixes: 04EMAES, 06EMAES, 07EMAES, 09EZAJS, 10EZAJS)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRGRA\u003c\/strong\u003e (Suffixes: 04EMAES, 06EMAES, 07EMAES)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRheem \/ Ruud RGL Series\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRGLQ\u003c\/strong\u003e (Suffixes: 07EAMER, 10EAMER)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRGLE\u003c\/strong\u003e (Suffixes: 07EAMER, 10EAMER)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWeatherKing \/ Corsaire Series\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWGRM\u003c\/strong\u003e (Suffixes: 04, 06, 07, 09, 10)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e80PJ\u003c\/strong\u003e (Suffixes: 07EAX, 10EAX)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Rheem","offers":[{"title":"Default Title","offer_id":52235521261931,"sku":"662766650228","price":330.83,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/70-23641-86.jpg?v=1772561111"},{"product_id":"goodman-b1370176-air-pressure-switch-0-60-wc-oem-furnace-safety-replacement","title":"Goodman B1370176 Air Pressure Switch -0.60\" WC | OEM Furnace Safety Replacement","description":"\u003ch1\u003e\u003cstrong\u003eGoodman B1370176 Air Pressure Switch -0.60\" WC OEM Furnace Safety Replacement\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e          The \u003cstrong\u003eGoodman B1370176 \u003c\/strong\u003eis a vital safety component that acts as the \"brain\" for the combustion air verification process. This \u003cstrong\u003egenuine OEM pressure switch \u003c\/strong\u003eis designed to monitor the \u003cstrong\u003enegative pressure \u003c\/strong\u003ecreated by the draft inducer motor, ensuring that flue gases are safely being exhausted before allowing the ignition sequence to proceed. It is \u003cstrong\u003especifically engineered for \u003c\/strong\u003ethe \u003cstrong\u003eGMS8\u003c\/strong\u003e, \u003cstrong\u003eGMS9\u003c\/strong\u003e, \u003cstrong\u003eGDS8\u003c\/strong\u003e, and \u003cstrong\u003eGDS9 \u003c\/strong\u003efurnace \u003cstrong\u003eseries\u003c\/strong\u003e. By verifying that the venting system is clear and the inducer is operating at peak performance, this switch \u003cstrong\u003eprevents \u003c\/strong\u003ethe \u003cstrong\u003efurnace from operating under hazardous conditions\u003c\/strong\u003e, such as a blocked flue or a failing blower.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenuine OEM Part Number B1370176:\u003c\/strong\u003e This is a factory-certified replacement, ensuring that the trip point matches the original safety calibration of your Goodman or Amana furnace.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecise Pressure Calibration:\u003c\/strong\u003e Set to a specific -0.60\" WC (Water Column) rating, this switch provides the exact sensitivity required to prove the draft without causing nuisance trips.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolves \"No Heat\" and Relay Errors:\u003c\/strong\u003e Replaces aging or \"stuck\" switches that cause the furnace to stay in a pre-purge loop or trigger a \"pressure switch stuck open\/closed\" fault code.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Safety Monitoring:\u003c\/strong\u003e Continuously monitors the vacuum pressure throughout the heating cycle, immediately shutting down the gas valve if a venting obstruction is detected.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Durability Diaphragm:\u003c\/strong\u003e Constructed with premium materials to resist the heat and moisture found in the burner compartment, ensuring long-term reliability compared to universal \"adjustable\" switches.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Details\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand: \u003c\/strong\u003eGoodman \/ Amana\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Goodman Manufacturing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart #: \u003c\/strong\u003eB1370176\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC\/SKU:\u003c\/strong\u003e 662766113940 \/ B1370176\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Weight: \u003c\/strong\u003e1lb\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 VAC (Control Circuit)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Set Point:\u003c\/strong\u003e -0.60\" WC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitch Type: \u003c\/strong\u003eNormally Open (Closes on pressure rise)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Type: \u003c\/strong\u003e1\/4\" Male Quick Connect Terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Induced Draft Safety Verification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e🛠️ HVAC Depot Pro Tip\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\"Check the Hose and Port First\"—before condemning the B1370176, inspect the small rubber vacuum hose connecting the switch to the inducer housing. Even a tiny crack or a bit of debris inside the plastic port on the inducer can prevent the switch from \"seeing\" the vacuum. Use a small paperclip to gently clear the inducer port of any rust or spider webs. If you install the new switch and the furnace still won't fire, verify that your inducer motor is reaching full speed and that your vent pipe isn't blocked by ice or a bird's nest.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCross-Reference\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eSuperseded \/ Legacy Numbers:\u003c\/strong\u003e\u003c\/h3\u003e\nB13701-76, B1370176S, 20197712, 107342-05\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eEquivalent Numbers:\u003c\/strong\u003e\u003c\/h3\u003e\nMPL-9300-V-0.60-DEACT, IS20352-5107\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eWhite-Rodgers \/ Emerson Equivalents:\u003c\/strong\u003e\u003c\/h3\u003e\n70-20602-01 (Logic Series)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eModel Compatibility\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMS8 \u003c\/strong\u003e(Suffixes: 0453ANA, 0703ANA, 0704BNA, 0904BNA, 0905CNA, 1155CNA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMS9\u003c\/strong\u003e (Suffixes: 0453BXA, 0703BXA, 0904CXA, 1155DXA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGDS8\u003c\/strong\u003e (Suffixes: 0453ANA, 0703ANA, 0904BNA, 1155CNA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGHS8 \u003c\/strong\u003e(Suffixes: 0453ANA, 0703ANA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDMS9 \u003c\/strong\u003e(Suffixes: 0453BXA, 0703BXA, 0904CXA, 1155DXA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDDS8 \u003c\/strong\u003e(Suffixes: 0453AXA, 0703AXA, 0904BXA, 1155CXA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGCH9\u003c\/strong\u003e (Suffixes: 0453BXA, 0703BXA, 0904CXA)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":52451499770219,"sku":"B1370176","price":94.57,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/original_51aa201e-884e-47b8-96bd-5a60739fddfc.jpg?v=1760124194"},{"product_id":"goodman-10690402s-blower-door-interlock-safety-switch-genuine-oem-replacement","title":"Goodman 10690402S Blower Door Interlock Safety Switch | Genuine OEM Replacement","description":"\u003ch1\u003e\u003cstrong\u003eGoodman 10690402S Blower Door Interlock Safety Switch | Genuine OEM Replacement\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe Goodman \u003cstrong\u003e10690402S \u003c\/strong\u003eis a vital genuine \u003cstrong\u003eOEM \u003c\/strong\u003esafety \u003cstrong\u003ecomponent \u003c\/strong\u003edesigned to function as the \"brain\" for electrical circuit protection within your \u003cstrong\u003efurnace\u003c\/strong\u003e \u003cstrong\u003ecabinet\u003c\/strong\u003e. This \u003cstrong\u003einterlock switch \u003c\/strong\u003eis a momentary contact device that monitors the position of the blower access panel. Specifically engineered for the \u003cstrong\u003eGMS8\u003c\/strong\u003e, \u003cstrong\u003eGDS8\u003c\/strong\u003e, and \u003cstrong\u003eGMP series\u003c\/strong\u003e, it acts as a primary fail-safe, \u003cstrong\u003einstantly cutting high\u003c\/strong\u003e-\u003cstrong\u003evoltage power to \u003c\/strong\u003ethe \u003cstrong\u003econtrol board and blower motor \u003c\/strong\u003eif the door is removed. Utilizing this factory-authorized replacement ensures your system remains compliant with \u003cstrong\u003eUL safety standards\u003c\/strong\u003e, preventing accidental contact with live electrical components or moving blower wheels during maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue OEM Specification:\u003c\/strong\u003e Explicitly manufactured under part number 10690402S to match the original factory spring tension and electrical contact ratings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstant Circuit Interruption:\u003c\/strong\u003e Engineered to fix specific \"intermittent power\" issues caused by weak internal springs or pitted electrical contacts in aging door switches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Voltage Safety Monitoring:\u003c\/strong\u003e Features a heavy-duty pole configuration capable of handling the full 120V input load, ensuring a 100% power lockout when the cabinet is breached.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSnap-In Installation Design:\u003c\/strong\u003e Designed for tool-free mounting in standard Goodman and Amana furnace chassis, providing a secure fit that won't vibrate loose during high-velocity airflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArc-Resistant Housing:\u003c\/strong\u003e Constructed from high-temp, flame-retardant plastic to prevent electrical tracking and ensure long-term reliability in the heat-stressed environment of the blower compartment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Details\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand: \u003c\/strong\u003eGoodman-Amana \/ Janitrol\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Daikin Comfort Technologies\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number: \u003c\/strong\u003e10690402S\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC: \u003c\/strong\u003e786710106904\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSKU:\u003c\/strong\u003e 10690402S\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e 1 lb\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 120 \/ 240 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage:\u003c\/strong\u003e 10A - 15A Rated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Type:\u003c\/strong\u003e SPST (Single Pole Single Throw), Normally Open (NO)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Size:\u003c\/strong\u003e 1\/4\" Male Spade Connectors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting: \u003c\/strong\u003eSnap-in Panel Mount\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e🛠️ HVAC Depot Pro Tip\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eTake a Picture of the Wire Terminals First: Before pulling the wires off the old switch, photograph the connections. These switches often use two black wires (hot leg), and reversing them won't affect the switch, but ensuring they are seated tightly on the new \u003cstrong\u003e10690402S spade terminals \u003c\/strong\u003eis critical for preventing electrical arcing. After installation, perform a Diagnostic Check by manually depressing the switch button with the door off; if the furnace powers up, you know the circuit is restored, but always ensure the door panel fully engages the switch when reinstalled.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCross-Reference\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eSuperseded \/ Legacy Numbers:\u003c\/strong\u003e\u003c\/h3\u003e\n10690402, B13708, B1370803, 0130F00025, 0130F00025S\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eHoneywell \/ Microswitch Equivalents: \u003c\/strong\u003e\u003c\/h3\u003e\nAC Series Interlock Switches\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eDrawing Numbers:\u003c\/strong\u003e\u003c\/h3\u003e\n1069-0402 Switch Assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eModel Compatibility\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMS8 \u003c\/strong\u003e(Suffixes: 0403AX, 0453AX, 0603AX, 0703AX, 0804BX, 0904BX, 1005CX, 1155CX)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGDS8 \u003c\/strong\u003e(Suffixes: 0403AX, 0603AX, 0804BX, 1005CX)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMP \u003c\/strong\u003e(Suffixes: 050-3, 075-3, 100-3, 100-4, 125-5, 150-5)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMPN \u003c\/strong\u003e(Suffixes: 040-3, 060-3, 080-4, 100-4, 120-5)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGHS8 \u003c\/strong\u003e(Suffixes: 0403AX, 0453AX, 0603AX)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMNT \u003c\/strong\u003e(Suffixes: 040-3, 060-3, 080-4, 100-4, 120-5)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":52451501048171,"sku":"10690402S","price":29.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/10690402S.jpg?v=1773157322"},{"product_id":"goodman-amana-pressure-switch-0-80-wc-0130f00507s","title":"Goodman | 0130F00507S | Air Pressure Switch | -0.80\" WC | Black Base","description":"\u003ch1\u003eGoodman 0130F00507S Air Pressure Switch -0.80\" WC\u003cbr\u003e\n\u003c\/h1\u003e\n\u003cp\u003e\u003cbr\u003eThe Goodman 0130F00507S is a high-precision, single-stage air pressure switch engineered specifically for Goodman GKS9 and GME8 series high-efficiency condensing furnaces. This safety-critical component monitors the specific negative static pressure generated by the inducer draft motor to ensure the secondary heat exchanger is clear of condensate or flue obstructions. Calibrated to a precise -0.80\" WC trip point, this switch prevents the ignition sequence from advancing if venting conditions are compromised. It is the direct factory replacement for the legacy B13702 series, designed to withstand the high-moisture environment inherent in 90%+ AFUE furnace cabinets. \u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenuine OEM Part #0130F00507S:\u003c\/strong\u003e This factory-authorized part ensures the exact -0.80\" WC calibration required to maintain your furnace's UL safety listing.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrosion-Resistant Diaphragm: \u003c\/strong\u003eFeatures an upgraded internal membrane designed to fix \"Stuck Open\" issues caused by acidic condensate buildup in high-efficiency systems.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect-Fit Replacement:\u003c\/strong\u003e Replaces older part numbers including 0130F00507 and B1370219, utilizing the same mounting footprint for a 5-minute installation.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCritical Safety Logic:\u003c\/strong\u003e Actively monitors for blocked vents or failing inducer motors, instantly cutting power to the gas valve if pressure drops below the safety threshold.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Details\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Goodman \/ Amana\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Daikin Comfort Technologies\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart #: \u003c\/strong\u003e0130F00507S\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC\/SKU:\u003c\/strong\u003e 662551465241 \/ 0130F00507S\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e 2. lbs\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 VAC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Setting:\u003c\/strong\u003e -0.80\" WC (Fixed)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Type: \u003c\/strong\u003e1\/4\" Male Spade Terminals \/ Single Barbed Hose Port \u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e🛠️ HVAC Depot Pro Tip\u003c\/h2\u003e\n\u003cp\u003eTake a Picture First: Before removing the original switch, photograph the wire positions and the direction of the vacuum hose. Diagnostic Check: If you receive a \"Pressure Switch Error\" code, inspect the silicone tubing for small \"pinholes\" or water traps (slugs). Even a perfectly functional 0130F00507S will fail to close if the vacuum line is restricted by a single drop of condensate or a cracked hose end.\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eCross-Reference\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuperseded:\u003c\/strong\u003e 0130F00507, 0130F00000P, 0130F00481\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLegacy:\u003c\/strong\u003e B13702-19, B1370219\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrawing Numbers:\u003c\/strong\u003e MPL-9300-V-0.80-LD-PF, 20188004\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhite-Rodgers\/Emerson Equivalents: \u003c\/strong\u003eOften paired with 50M56-289 and 50A65 series Goodman control modules.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eModel Compatibility\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGKS9 \u003c\/strong\u003e(Suffixes: 0453AX, 0704BX, 0905CX, 1155DX)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGME8 \u003c\/strong\u003e(Suffixes: 0403AX, 0603AX, 0804BX, 1005CX)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMH95 \u003c\/strong\u003e(Suffixes: 0453AA, 0703AA, 0904BA, 1155CA)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAMH95 \u003c\/strong\u003e(Suffixes: 0453AA, 0704BA, 0905CA)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":52563285836139,"sku":"0130F00507S","price":35.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/0130F00507S.jpg?v=1763413759"},{"product_id":"goodman-amana-0130f00505s-b1370158-0130f00505-spst-pressure-switch","title":"Goodman-Amana 0130F00505S-SPST (-.70) Pressure Switch","description":"\u003cp\u003eThe 0130F00505S pressure switch is a Goodman\/Amana\/Janitrol furnace safety device, a key part that ensures the inducer motor creates correct airflow for safe venting by monitoring pressure changes, typically set at -0.70 inches of water column (WC) to prevent carbon monoxide buildup. It's a crucial safety component, ensuring proper vacuum before the burners ignite, and is a common replacement for various Goodman furnace models. \u003c\/p\u003e\n\u003cp\u003eThe primary function of 0130F00505S is to senses the air pressure difference (differential) between the combustion chamber and the inducer motor's outlet. If the pressure isn't right (meaning the motor isn't working or the vent is blocked), the switch prevents the burners from firing, stopping the furnace and avoiding dangerous carbon monoxide (CO) buildup. This is a vital safety control that checks if the furnace's inducer motor is running correctly and producing enough suction (vacuum) to vent exhaust gases outside.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand: \u003c\/strong\u003eGoodman, Amana, Janitrol.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Setting:\u003c\/strong\u003e -0.70 inches of Water Column (WC).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType: \u003c\/strong\u003eSPST (Single Pole, Single Throw).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Configuration: \u003c\/strong\u003eSPST\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Rating: \u003c\/strong\u003e5 AMP Max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e 2 LBS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Type: \u003c\/strong\u003eQuick Disconnect\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Air \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperation: \u003c\/strong\u003eNormally Open(NO)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe primary manufacturer part numbers associated with the 0130F00505S are:\u003c\/strong\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e0130F00505:\u003c\/strong\u003e This is essentially the same part number, sometimes listed without the \"S\" suffix.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB1370158:\u003c\/strong\u003e The 0130F00505S is designed as a direct replacement for this older Goodman, Amana, and Janitrol part number.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e9371VO-HS-0008: \u003c\/strong\u003eThis number has also been associated with the same pressure switch by some suppliers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eL39-257: \u003c\/strong\u003eThis is an internal order or catalog number used by Johnstone Supply for the same part. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eBelow are some of the specific furnace model numbers compatible with the 0130F00505S pressure switch:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGoodman Gas Furnaces:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGM9S800403, GM9S80080, GM9S801005\u003c\/li\u003e\n\u003cli\u003eGMES800403, GMES80080, GMES801005\u003c\/li\u003e\n\u003cli\u003eGMP100-42, GMP100-42EA\u003c\/li\u003e\n\u003cli\u003eGME80905CX, GME81005CN, GME81005CX\u003c\/li\u003e\n\u003cli\u003eGMES800403ANAA, GMES800803BNAA\u003c\/li\u003e\n\u003cli\u003eGMS80453AN, GMH80804BX\u003c\/li\u003e\n\u003cli\u003eGMH81155CX, GMH81155CN\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAmana Gas Furnaces:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAM9S800403, AM9S80080, AM9S801005\u003c\/li\u003e\n\u003cli\u003eAMES800403, AMES80080, AMES801005\u003c\/li\u003e\n\u003cli\u003eAMES800403AXAA, AMES800803BXAA\u003c\/li\u003e\n\u003cli\u003eAMH80803BX\/AMH80803BXBB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDaikin Gas Furnaces:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDM80SE0403, DM80SE080, DM80SE1005\u003c\/li\u003e\n\u003cli\u003eDM80SN0403, DM80SN080, DM80SN1005\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":52563591758187,"sku":"0130F00505S","price":48.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/0130f00505-1.jpg?v=1763414018"},{"product_id":"goodman-amana-air-pressure-switch-60-wc-0130f00504s","title":"Goodman-Amana Air Pressure Switch (.60\" WC), 0130F00504S","description":"\u003ch1\u003eGoodman-Amana Air Pressure Switch (.60\" WC), 0130F00504S\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eGoodman 0130F00504\u003c\/strong\u003e is a high-sensitivity \u003cstrong\u003eGenuine OEM Air Pressure Switch\u003c\/strong\u003e engineered for Goodman and Amana high-efficiency gas furnaces. This critical safety device monitors the \"draft\" created by the inducer motor, ensuring that combustion gases are being properly vented and that there is sufficient airflow for a safe, clean burn.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Performance:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eFactory-calibrated to a precise setpoint of \u003cstrong\u003e0.60\" WC (Water Column)\u003c\/strong\u003e, this \u003cstrong\u003eSingle-Pole Single-Throw (SPST)\u003c\/strong\u003e switch remains open until the inducer motor creates the required vacuum. Once the threshold is met, the internal diaphragm closes the electrical circuit to the ignition board. Its \u003cstrong\u003e0.25-inch barb\u003c\/strong\u003e connection ensures a leak-free seal with standard furnace pressure tubing, preventing the \"intermittent ignition\" errors common with failing aftermarket switches.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features and Function:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFeature 1: Precision Draft Monitoring:\u003c\/strong\u003e Calibrated to 0.60\" WC to match the specific static pressure requirements of Goodman 80% and 90%+ AFUE furnaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFeature 2: Snap-Action Safety:\u003c\/strong\u003e The SPST normally-open contact design ensures the furnace cannot ignite if the vent is blocked or the inducer fails.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFeature 3: Corrosion-Resistant Diaphragm:\u003c\/strong\u003e Built with high-grade silicone and plastic housing to resist the acidic condensate found in high-efficiency venting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFeature 4: Direct-Fit Mounting:\u003c\/strong\u003e Features a universal mounting bracket for a \"drop-in\" replacement of older or superseded metal-body switches.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Details and Key Specifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 0130F00504 (Replaces 0130F00000P, B13701-42)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Goodman \/ Amana (Genuine OEM)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Type:\u003c\/strong\u003e Inducer Air Pressure Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSetpoint:\u003c\/strong\u003e 0.60\" WC (PF)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Arrangement:\u003c\/strong\u003e SPST (Normally Open)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Type:\u003c\/strong\u003e 1\/4\" (0.25 in) Hose Barb\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Rating:\u003c\/strong\u003e 24V \/ 60Hz Control Circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e 0.3 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e🛠️ \u003cstrong\u003eHVAC Depot Pro Tip: The \"Paperclip\" Port Check\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cp\u003eBefore replacing this switch, always check the plastic \"vacuum port\" on the inducer motor housing. These ports often get clogged with a tiny amount of corrosion or debris. If the port is blocked, the switch won't \"see\" the pressure, and the furnace won't fire. Use a small paperclip or a 1\/16\" drill bit to gently clear the port before installing the new 0130F00504.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCross-Reference \u0026amp; Compatibility:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003e0130F00504\u003c\/strong\u003e is a direct OEM replacement for the following part numbers:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Numbers:\u003c\/strong\u003e 0130F00000P, 0130F00000, B13701-42, B1370142, 107321-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustry Refs:\u003c\/strong\u003e MPL-9300, IS20436-5471\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eExtensive Model Compatibility List:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eNote: Use 'CTRL+F' to search for your specific model:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGoodman GMS8 Series:\u003c\/strong\u003e GMS80403AN, GMS80603AN, GMS80604BN, GMS80803AN, GMS80804BN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGoodman GDS8 Series:\u003c\/strong\u003e GDS80403AN, GDS80603AN, GDS80804BN, GDS81005CN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmana AMES8 Series:\u003c\/strong\u003e AMES80403AN, AMES80603AN, AMES80804BN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaged Units:\u003c\/strong\u003e GPG, APG, GPC Series\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":52563657490795,"sku":"193031196665","price":35.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/0130f00504s_0779a4da-e3b1-4cc0-8def-07e828240288.jpg?v=1763414774"},{"product_id":"goodman-0130f00509-dual-air-pressure-switch-0-10-0-45-pf","title":"Goodman | 0130F00509 | Dual Air Pressure Switch | -0.10\" \/ -0.45\" PF","description":"\u003ch1\u003eGoodman | 0130F00509 | Dual Air Pressure Switch | -0.10\" \/ -0.45\" PF\u003c\/h1\u003e\n\u003cp\u003eThis genuine OEM Goodman-Amana Dual Air Pressure Switch is a critical safety component specifically designed for Goodman GME8 and Amana AMEH8 series multi-speed furnaces. This high-precision sensor monitors the negative pressure created by the inducer motor to ensure the venting system is clear of obstructions before the ignition sequence begins. Unlike universal single-stage switches, this dual-stack configuration (incorporating logic from the 0130F00049 and B1370210 legacy series) is calibrated to specific set points—typically -0.10\" and -0.45\" PF—to protect the heat exchanger from hazardous flue gas buildup.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eKey Features\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenuine OEM Part #0130F00509: \u003c\/strong\u003eFactory-authorized replacement ensuring the exact pressure trip points required for your furnace’s safety certification.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-Stage Monitoring:\u003c\/strong\u003e Integrated dual-switch design manages both low-fire and high-fire inducer speeds, a feature often missed by \"universal\" aftermarket kits.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFixes Ignition Failures:\u003c\/strong\u003e Specifically designed to resolve \"Pressure Switch Stuck Open\" or \"Stuck Closed\" error codes (Flash Code 2 or 3) on Goodman control boards.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Upgrade: \u003c\/strong\u003eReplaces older B1370210 designs with improved diaphragm materials that resist cracking and moisture-related failure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003eProduct Details\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Goodman \/ Amana\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Daikin Comfort Technologies\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart #:\u003c\/strong\u003e 0130F00509\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC\/SKU: \u003c\/strong\u003e 193031196696\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e 0.4 lbs\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitch Type:\u003c\/strong\u003e Dual Stack (Normally Open)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Settings:\u003c\/strong\u003e -0.10\" PF \/ -0.45\" PF\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e Barbed (Hose) and 1\/4\" Male Spades\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e🛠️ HVAC Depot Pro Tip\u003c\/h2\u003e\n\u003cp\u003eTake a Picture First: Before pulling the vacuum hoses, photograph the routing. Reversing the hoses on a dual-stack switch will prevent the furnace from entering high-fire mode. Diagnostic Check: If the new switch doesn't close, use a small paperclip to ensure the plastic \"port\" on the inducer housing is clear of debris or spider webs; often, the switch is fine, but the tiny orifice is clogged.\u003c\/p\u003e\n\u003ch2\u003eCross-Reference\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuperseded: \u003c\/strong\u003e0130F00049, 0130F00049S, B13702-10\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLegacy:\u003c\/strong\u003e B1370210, 0130F00438\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrawing Numbers:\u003c\/strong\u003e MPL-9300-V-0.10-LD-PF \/ MPL-9390-V-0.45-LD-PF\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eModel Compatibility\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGME8\u003c\/strong\u003e (Suffixes: 0403AX, 0603AX, 0804BX, 1005CX)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAMEH8 \u003c\/strong\u003e(Suffixes: 0403AX, 0603AX, 0804BX, 1005CX)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGDH8 \u003c\/strong\u003e(Suffixes: 0403AX, 0604BX, 0805CX)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGCH8 \u003c\/strong\u003e(Suffixes: 0453AX, 0704BX, 0905CX)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":52563750420843,"sku":"0130F00509","price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/0130F00509.jpg?v=1763482955"},{"product_id":"goodman-0130f00042p-air-pressure-switch-genuine-oem-0-40-wc-24v","title":"Goodman 0130F00042P Air Pressure Switch | Genuine OEM -0.40\" WC 24V","description":"\u003ch1\u003eGoodman 0130F00042P Furnace Air Pressure Switch – Genuine OEM -0.40\" WC 24V Plastic Housing\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eGoodman 0130F00042P Pressure Switch\u003c\/strong\u003e is the critical safety \"sentinel\" responsible for verifying proper combustion venting in your gas furnace. This 24V vacuum-actuated switch monitors the negative pressure created by the inducer motor; it will only \"close\" its internal electrical contacts if it detects a safe draft of \u003cstrong\u003e-0.40\" WC\u003c\/strong\u003e. Specifically engineered for \u003cstrong\u003eGoodman, Amana, and Janitrol\u003c\/strong\u003e furnace series, this switch acts as a mandatory safety gatekeeper. If the vent is blocked, the inducer fails, or the heat exchanger is compromised, the switch stays \"open,\" instantly preventing the ignition sequence to protect your home from hazardous flue gas backup.\u003c\/p\u003e\n\u003ch2\u003eKey Features and Function:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision Draft Management:\u003c\/strong\u003e Factory-calibrated to trip at exactly -0.40\" Water Column (WC) to ensure the furnace only fires under optimal venting conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenuine OEM Reliability\/Fitment:\u003c\/strong\u003e Features the exact mounting footprint and vacuum port orientation required for a \"drop-in\" installation on Goodman collector boxes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Logic Integration:\u003c\/strong\u003e Directly communicates with the furnace control board to trigger \"Pressure Switch Open\" fault codes, ensuring rapid and accurate troubleshooting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Plastic Construction:\u003c\/strong\u003e Engineered with high-grade, heat-resistant plastic and a sensitive internal diaphragm designed to endure thousands of heating cycles without calibration drift.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Details and Key Specifications:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 0130F00042P (Replaces 0130F00042, B1370142)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Goodman \/ Amana (Genuine OEM)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Type:\u003c\/strong\u003e Air Pressure Switch \/ Vacuum Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSetpoint:\u003c\/strong\u003e -0.40\" WC (Fixed)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContacts:\u003c\/strong\u003e Normally Open (NO)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e High-Temp Plastic Housing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector:\u003c\/strong\u003e 1\/4\" Male Quick-Connect Terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e 0.3 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e🛠️ HVAC Depot Pro Tip: The \"Hose and Port\" Check\u003c\/h2\u003e\n\u003cp\u003eIf your furnace is throwing a \"Pressure Switch\" error code, the switch itself is rarely the failed part. Before replacing the \u003cstrong\u003e0130F00042P\u003c\/strong\u003e, perform a \u003cstrong\u003eDiagnostic Check\u003c\/strong\u003e on the rubber vacuum hose and the small plastic port on the inducer housing. Use a small wire or paperclip to ensure the port is clear of rust or debris. If the hose is cracked or the port is clogged, the switch cannot \"sense\" the vacuum and will stay open. Always ensure the hose is seated tightly to prevent \"nuisance\" tripping.\u003c\/p\u003e\n\u003ch2\u003eCross-Reference \u0026amp; Compatibility:\u003c\/h2\u003e\n\u003cp\u003eThe 0130F00042P is a direct OEM replacement for the following part numbers:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Numbers:\u003c\/strong\u003e 0130F00042, 0130F00042P, B1370142, B13701-42\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHoneywell:\u003c\/strong\u003e IS20400-3814\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAftermarket Cross:\u003c\/strong\u003e ClimaTek 0130F00042, Mars 39042\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eExtensive Model Compatibility List:\u003c\/h2\u003e\n\u003cp\u003eNote: Use 'CTRL+F' to search for your specific model:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGoodman GMS8 Series:\u003c\/strong\u003e GMS80403AN, GMS80603AN, GMS80804BN, GMS81005CN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGoodman GDS8 Series:\u003c\/strong\u003e GDS80403AX, GDS80603AX, GDS80804BX, GDS81005CX\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGoodman GMH95 Series:\u003c\/strong\u003e GMH950453BX, GMH950703BX, GMH950904CX\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmana AMES8 Series:\u003c\/strong\u003e AMES80403AN, AMES80603AN, AMES80804BN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJanitrol GMP Series:\u003c\/strong\u003e GMP050-3, GMP075-3, GMP100-3, GMP125-4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Units:\u003c\/strong\u003e GPG, GPH, APG series (Used for combustion air verification)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":52572355461483,"sku":"B1370126","price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/B1370126.jpg?v=1763414398"},{"product_id":"air-pressure-switch-35-wc-b1370133","title":"Goodman P\/N B1370133 – Genuine OEM Furnace Pressure Switch (Single Stage, -0.35\" WC, Normally Open)","description":"\u003ch1\u003eGoodman P\/N B1370133 – Genuine OEM Furnace Pressure Switch (Single Stage, -0.35\" WC, Normally Open)\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eGoodman B1370133\u003c\/strong\u003e is a Genuine Original Equipment Manufacturer (OEM) furnace pressure switch, designed for use in Goodman, Amana, and Janitrol residential gas furnaces. This single-stage, negative pressure-activated switch is a vital safety component, engineered to monitor the draft created by the induced draft motor and prove that the furnace venting system is clear before allowing the main gas valve to open and ignite the burners.\u003c\/p\u003e\n\u003cp\u003eAs an authentic OEM component from Goodman, the B1370133 ensures precise set-point calibration (\u003cstrong\u003e-0.35 inches of water column, \" WC\u003c\/strong\u003e) required by the control board. It features a durable yellow plastic construction, a single-port 1\/4\" barb connection (Normally Open contacts), and specific mounting hardware for a seamless, secure installation. Choosing the original factory part prevents nuisance \"pressure switch lockout\" errors and maintains the furnace's critical safety certifications.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features and Function:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Interlock:\u003c\/strong\u003e Proves successful venting operation to the control board before ignition can occur.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenuine OEM Reliability:\u003c\/strong\u003e Official Goodman replacement built to factory standards for exact fitment and calibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecise Calibration:\u003c\/strong\u003e Factory-set to -0.35\" WC for reliable operation specific to compatible furnace designs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle Stage Design:\u003c\/strong\u003e Simple, robust design (SPST, Normally Open) for use in standard single-stage heating systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Details and Key Specifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e B1370133\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSKU:\u003c\/strong\u003e B1370133\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Goodman (Daikin\/Amana)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Type:\u003c\/strong\u003e Pressure Switch (Single Stage, Negative Pressure)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitch Type:\u003c\/strong\u003e SPST (Single Pole, Single Throw), Normally Open contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSet Point:\u003c\/strong\u003e -0.35 inches of Water Column (\" WC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnections:\u003c\/strong\u003e Single Port, 1\/4\" barb fitting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Plastic, Yellow\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage:\u003c\/strong\u003e 24 VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e🛠️ HVAC Depot Pro Tip: Troubleshooting the Pressure Switch Circuit\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eIf your furnace is running the inducer motor but immediately locks out (flashing the pressure switch fault code), the issue isn't always the B1370133 switch itself. First, check the rubber tubing connecting the switch to the inducer motor for cracks, blockages, or water accumulation. Second, ensure the furnace's intake and exhaust vents outside are clear of snow, ice, or debris. Only after verifying these common issues should you test the switch with a manometer to confirm it is pulling exactly -0.35\" WC and closing the circuit.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCross-Reference:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe B1370133 is a direct OEM replacement for the following part numbers:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM \u0026amp; Catalog Numbers:\u003c\/strong\u003e B1370133, B13701-33, P272805, B1370138.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Cross:\u003c\/strong\u003e MPL 9300-V-0.35-N\/O-VS.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eExtensive Model Compatibility List:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cem\u003eNote: Use 'CTRL+F' to search for your specific model:\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eGoodman\/Amana Furnaces (Specific Models):\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eGDPI120-5, GDPS120-5, GDPX120-5B, GMP050-32, GMP075-3\u003c\/li\u003e\n\u003cli\u003eGMP075-32, GMP075-4, GMPE075-3, GMPE075-3A, GMPH075-4\u003c\/li\u003e\n\u003cli\u003eGMPV075-1.5, GMPV075-3, GPD075-3, GPG12481151A, GPG12600901A\u003c\/li\u003e\n\u003cli\u003eGSM080-4, GSMS060-3, GSMS080-4, GSMS100-4, GSU080-4\u003c\/li\u003e\n\u003cli\u003eGUPI120-5, GUPS120-4, GUPS120-5, GUPS140-5, PGB036075-1B\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1 font-size=\"h5,,h4,,h2\" font-weight=\"bold\" class=\"Box-sc-1z9git-0 LTumJ\"\u003e\u003cspan\u003ePressure Switch, Air, -0.35 in wc, NO, 24 V, Plastic, Yellow\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch3 class=\"product-sku bold-font-xs slds-m-bottom_large\"\u003eB1370133\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli class=\"text-regular-font-md text-color\"\u003e\u003cspan\u003eParts and Accessories\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"text-regular-font-md text-color\"\u003e\u003cspan\u003ePressure Switch, Air, -0.35 in wc Measuring, NO, 24 V, Plastic, Yellow\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"text-regular-font-md text-color\"\u003e\u003cspan\u003eAccessory\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThis item is compatible with the following \u003cb\u003eGoodman-Amana\u003c\/b\u003e model numbers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eGMPE075-3A\/GMPE075-3A\u003cbr\u003eGSU080-4\/GSU080-4\u003cbr\u003eGMP075-32C\u003cbr\u003eGDPX120-5B\/GDPX120-5B\u003cbr\u003eGSM080-4\u003cbr\u003eGPD075-3\u003cbr\u003eGMPH075-4\u003cbr\u003eGMP075-32\u003cbr\u003eGUPS120-4\/GUPS120-4\u003cbr\u003eGMP050-32\u003cbr\u003eGUPS140-5\/GUPS140-5\u003cbr\u003eGUPS120-5\/GUPS120-5\u003cbr\u003eGMPE075-3\u003cbr\u003eGMP075-4\u003cbr\u003eGMP050-32C\u003cbr\u003eGMP075-3\u003c\/span\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":52572374172011,"sku":"193031151657","price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/B1370133.jpg?v=1768668777"},{"product_id":"trane-american-standard-swt03305-pressure-switch-direct-replacement","title":"Trane SWT03305 Furnace Pressure Switch | Genuine OEM Replacement C342634P40","description":"\u003ch1\u003eTrane \u0026amp; American Standard SWT03305 Furnace Pressure Switch\u003c\/h1\u003e\n\u003cp\u003eIs your furnace failing to ignite or throwing a 2 flash or 3 flash error code? The Trane SWT03305 is essential safety component your system needs to verify proper venting. This is a genuine OEM Trane and American Standard pressure switch that is used in residential furnaces to ensure safe operation by monitoring pressure levels. It is an OEM replacement part that opens at -1.51 inches of water column WC and closes at -1.73 WC. The pressure switch is a safety component that detects if there is enough air pressure for the furnace to run safely. When the pressure switch is not activated the gas valve will not open. You can find this pressure switch in Trane and American Standard Run Tru\/Ameristar HVAC systems and is designed to be a genuine OEM direct replacement replacement part on residential furnaces.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Performance Features:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenuine OEM Quality:\u003c\/strong\u003e Specifically engineered for Trane, American Standard, and Ameristar\/Run Tru residential furnaces.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First Design: \u003c\/strong\u003eFactory-calibrated to Open at -1.51\" WC and Close at -1.73\" WC for precise airflow monitoring.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSimple Swap-Out: \u003c\/strong\u003eStandard 1\/4\" quick-connect terminals and built-in mounting bracket mean you can get the heat back on in minutes.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHoneywell Engineered: \u003c\/strong\u003eManufactured for Trane Technologies to provide superior durability in high-cycle environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand: \u003c\/strong\u003eTrane\/American Standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e SWT03305\/SWT3305\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Configuration: \u003c\/strong\u003eNO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles: \u003c\/strong\u003e1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Weight: \u003c\/strong\u003e0.318\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Type: \u003c\/strong\u003e1\/4 X 0.032 Quick connect\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType: \u003c\/strong\u003ePressure switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen at: \u003c\/strong\u003e-1.51 inches of water column (WC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClose at:\u003c\/strong\u003e -1.73 inches of water column (WC) \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThe SWT03305 pressure switch directly replaces the following OEM part numbers: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSWT3305 (shortened version)\u003c\/li\u003e\n\u003cli\u003eSSWT03305\u003c\/li\u003e\n\u003cli\u003eC342634P40\u003c\/li\u003e\n\u003cli\u003eC342634P40-SP\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Trane SWT03305 assembly also cross-references to third-party and aftermarket part numbers, as it is often a Honeywell manufactured component rebranded for Trane: \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIngersoll Rand SWT3305\u003c\/li\u003e\n\u003cli\u003eService First SSWT03305\u003c\/li\u003e\n\u003cli\u003eHoneywell-made equivalents (specific model number often found directly on the switch itself) \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThis part is found in the following model numbers:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmerican Standard Models:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAUH1B080A9421BA\u003c\/li\u003e\n\u003cli\u003eAUH1B080A9421BB\u003c\/li\u003e\n\u003cli\u003eAUH1B080A9421CA\u003c\/li\u003e\n\u003cli\u003eAUH1B080A9421CB\u003c\/li\u003e\n\u003cli\u003eAUH1B080A9H31BA\u003c\/li\u003e\n\u003cli\u003eAUH1B080A9H31CA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAmeristar\/Run Tru Models:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eM951P080BU42ABA\u003c\/li\u003e\n\u003cli\u003eM951P080BU42ABB\u003c\/li\u003e\n\u003cli\u003eM951P080BU42ABC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrane Models:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTUH1B080A9421BA\u003c\/li\u003e\n\u003cli\u003eTUH1B080A9421BB\u003c\/li\u003e\n\u003cli\u003eTUH1B080A9421CA\u003c\/li\u003e\n\u003cli\u003eTUH1B080A9421CB\u003c\/li\u003e\n\u003cli\u003eTUH1B080A9H31BA\u003c\/li\u003e\n\u003cli\u003eTUH1B080A9H31CA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTroubleshooting Guide\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch3\u003eHow to Tell if Your SWT03305 has Failed:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInducer motor runs, but burners won't light: \u003c\/strong\u003eThe switch may be stuck \"open\" or the diaphragm is ruptured.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Switch Stuck Open Error: \u003c\/strong\u003eCheck for blocked flues or cracked vacuum hoses first.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisible Damage:\u003c\/strong\u003e Look for melted plastic or corroded terminals.\u003cbr\u003ePro Tip: Use a digital manometer to verify your system is hitting at least -1.73\" WC before assuming the switch is bad.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trane \/ American Standard","offers":[{"title":"Default Title","offer_id":52576139510123,"sku":"SWT03305","price":105.22,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/SWT03305.jpg?v=1765314471"},{"product_id":"trane-direct-replacement-swt02522-air-pressure-switch","title":"Trane SWT02522 Pressure Switch | Replaces C341825P23, SWT01671, X13200296230","description":"\u003ch1\u003e\u003cstrong\u003eTrane \u0026amp; American Standard SWT02522 SPST Pressure Switch\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp\u003eWhen your furnace isn't venting correctly, the Trane SWT02522 pressure switch is the critical safety component that stops the system from running dangerously. This genuine OEM replacement ensures your system maintains proper air pressure (rated at 1.15\" W.C.), preventing ignition issues and keeping your home safe. It's the reliable, direct-fit replacement you need to get the heat back on fast.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Performance Features:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eOEM Certified Reliability:\u003c\/strong\u003e\u003c\/h3\u003e\nA genuine Trane part, guaranteed to meet all safety and performance standards for American Standard and Run Tru systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eDurable Build Quality:\u003c\/strong\u003e\u003c\/h3\u003e\nFeatures a robust brass body and stainless steel diaphragm, built to last longer than aftermarket alternatives.\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003ePrecise Calibration:\u003c\/strong\u003e\u003c\/h3\u003e\nFactory-set to ensure proper operation within the 1.15\" to 1.34\" W.C. range.\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cstrong\u003eHigh-Amp Electrical Rating:\u003c\/strong\u003e\u003c\/h3\u003e\nSafely handles up to 15A at 125 VAC, a key spec many universal switches miss.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features And Specifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand: \u003c\/strong\u003eTrane\/American Standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Configuration: \u003c\/strong\u003eSPST\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Rating: \u003c\/strong\u003e5A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles: \u003c\/strong\u003e1\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePressure Rating: \u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Operating:\u003c\/strong\u003e 3 In-WC ,\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax: \u003c\/strong\u003ePR Setpoint, 1.34 In-WC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMin: \u003c\/strong\u003e1.15 In-WC PF14 In-WC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Range: \u003c\/strong\u003e1.15- 1.34 WC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Weight: \u003c\/strong\u003e1.308\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Type: \u003c\/strong\u003eQuick Disconnect\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType: \u003c\/strong\u003eAir\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong Description: \u003c\/strong\u003eSWITCH; PRESSURE, IS2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eThe SWT02522 pressure switch directly replaces the following OEM part numbers: \u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSWT2522\u003c\/li\u003e\n\u003cli\u003eSWT01671\u003c\/li\u003e\n\u003cli\u003eC341825P23\u003c\/li\u003e\n\u003cli\u003eX13200296230\u003c\/li\u003e\n\u003cli\u003eHoneywell C341825P23\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePressure Switch is commonly found in the following models:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eAmerican Standard:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAUC1B080A9421AA\u003c\/li\u003e\n\u003cli\u003eAUX080C942D3\u003c\/li\u003e\n\u003cli\u003eAUX1B080A9421AA\u003c\/li\u003e\n\u003cli\u003eAUX1B080A9H31AA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eRun TRU:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCUX080A942A0\u003c\/li\u003e\n\u003cli\u003eCUX1B080A9421AA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTrane:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTUC1B080A9421AA\u003c\/li\u003e\n\u003cli\u003eTUX080C942D3\u003c\/li\u003e\n\u003cli\u003eTUX1B080A9421AA\u003c\/li\u003e\n\u003cli\u003eTUX1B080A9H31AA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cstrong class=\"Yjhzub\" data-complete=\"true\" data-processed=\"true\" aria-owns=\"action-menu-parent-container\"\u003e🛠️ HVAC Depot Pro Tip\u003c\/strong\u003e:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSymptom:\u003c\/strong\u003e Furnace Won't Ignite, displays \"No Airflow\" or \"Pressure Switch Error\" code.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFix Tip: \u003c\/strong\u003eCheck the clear plastic tubing connecting the switch to the inducer fan for cracks or blockages first. Moisture buildup can also freeze and prevent proper operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trane \/ American Standard","offers":[{"title":"Default Title","offer_id":52576575684971,"sku":"SWT02522","price":98.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/swt2522-2.jpg?v=1764100803"},{"product_id":"oem-trane-flame-rollout-switch-swt02649-opens-at-240f-manual-reset","title":"Trane SWT02649 Flame Rollout Switch | 240°F Manual Reset | Replaces 3L12-240, SRL240","description":"\u003ch1\u003eTrane SWT02649 Flame Rollout Switch | 240°F Manual Reset | Replaces 3L12-240 \u0026amp; SRL240\u003c\/h1\u003e\n\u003cp\u003eTrane SWT02649 is a flame rollout switch, a safety component for HVAC systems that manually resets and is designed to protect against overheating inside the cabinet. It's a Single Pole Single Throw (SPST) switch that opens (shuts the system off) if it detects a flame rollout, which can happen in a furnace. This specific model operates at 240°F and is compatible with various Trane and American Standard HVAC systems. This as a safety device by monitoring for flame rollout in the burner area and inside the cabinet. When a flame issues from the burner area, it triggers a safety shutdown. It has a manual reset, meaning a person must manually reset it to restart the system after the issue is fixed. It is a Single Pole Single Throw (SPST) switch that opens at 240°F and is rated for 240 volts and 25 amps. The flame rollout switch is a crucial safety component that prevents overheating and potential hazards associated with a flame rollout, protecting both the equipment and occupants.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eKey  Electrical Specifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand: \u003c\/strong\u003eTrane\/ American Standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Rating: \u003c\/strong\u003e25A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles: \u003c\/strong\u003e1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Weight: \u003c\/strong\u003e0.186\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Type: \u003c\/strong\u003eQuick Connect\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType: \u003c\/strong\u003eManual Reset\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage: \u003c\/strong\u003e208-230\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmps: \u003c\/strong\u003e25 Max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlame Rollout MAX Temp: \u003c\/strong\u003eOpens and needs to be reset at 240F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDescription: \u003c\/strong\u003eSWITCH; FLAME ROLLOUT, 240F, OPENS ON TEMP RISE, MANUAL RESET, SPST, 25A\/240V QC TERMINAL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eThe SWT02649 directly replaces the following Trane and American Standard part numbers: \u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSWT2649 (older version of the same part number)\u003c\/li\u003e\n\u003cli\u003eX13100426010\u003c\/li\u003e\n\u003cli\u003eX13541189-01\u003c\/li\u003e\n\u003cli\u003e389683\u003c\/li\u003e\n\u003cli\u003eService First SSWT02649\u003c\/li\u003e\n\u003cli\u003eAll Points 8110614 \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhite-Rodgers:\u003c\/strong\u003e 3L12-240\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupco: \u003c\/strong\u003eSRL240:\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackard: \u003c\/strong\u003ePRL240:\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eICP \/ Heil Quaker: \u003c\/strong\u003e512532:\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNordyne\/Maytag:\u003c\/strong\u003e 626605 or 626355\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReznor: \u003c\/strong\u003e210855\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMARS: \u003c\/strong\u003e39042\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStop Furnace Overheating with the Trane SWT02649\u003c\/h2\u003e\n\u003cp\u003eIf your package unit or furnace has completely shut down and won't respond to the thermostat, your flame rollout switch likely tripped. The SWT02649 is a Single Pole Single Throw (SPST) safety device that monitors the burner cabinet.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePro-Tip for Techs:\u003c\/strong\u003e Because this is a\u003cstrong\u003e Manual Reset\u003c\/strong\u003e switch, a trip usually indicates a serious issue like a clogged burner or a cracked heat exchanger. Do not just reset it—inspect the combustion area! This switch is the \"gold standard\" replacement for\u003cstrong\u003e Service First SSWT02649\u003c\/strong\u003e and \u003cstrong\u003eHoneywell\u003c\/strong\u003e equivalents found in major Trane and American Standard commercial and residential package units.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMost Commonly Found in the following Trane\/American Standard Package units:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGCC180A3EHA0907\u003c\/li\u003e\n\u003cli\u003eGCC180A3EHA0A07\u003c\/li\u003e\n\u003cli\u003eGCC180A3EHA0B07\u003c\/li\u003e\n\u003cli\u003eGCC180A3EHA0BC7\u003c\/li\u003e\n\u003cli\u003eGCC180A3EHA0BD7\u003c\/li\u003e\n\u003cli\u003eGCC180A3EHA0BN70B\u003c\/li\u003e\n\u003cli\u003eGCC180A3EHA0C07\u003c\/li\u003e\n\u003cli\u003eGCC180A3EHA0CC7\u003c\/li\u003e\n\u003cli\u003eGCC180A3EHA0CD7\u003c\/li\u003e\n\u003cli\u003eGCC180A3EHA0D07\u003c\/li\u003e\n\u003cli\u003eGCC180A3EHA0D09\u003c\/li\u003e\n\u003cli\u003eGCC180A3EHA0DD7\u003c\/li\u003e\n\u003cli\u003eGCC180A3ELA0907\u003c\/li\u003e\n\u003cli\u003eGCC180A3ELA0A07\u003c\/li\u003e\n\u003cli\u003eGCC180A3ELA0B07\u003c\/li\u003e\n\u003cli\u003eGCC180A3ELA0C07\u003c\/li\u003e\n\u003cli\u003eGCC180A3ELA0D07\u003c\/li\u003e\n\u003cli\u003eGCC180A3EMA0C07\u003c\/li\u003e\n\u003cli\u003eGCC180A4EHA0A07\u003c\/li\u003e\n\u003cli\u003eGCC180A4EHA0B07\u003c\/li\u003e\n\u003cli\u003eGCC180A4EHA0C07\u003c\/li\u003e\n\u003cli\u003eGCC180A4EHA0D07\u003c\/li\u003e\n\u003cli\u003eGCC180A4ELA0A07\u003c\/li\u003e\n\u003cli\u003eGCC180A4ELA0B07\u003c\/li\u003e\n\u003cli\u003eGCC180A4ELA0C07\u003c\/li\u003e\n\u003cli\u003eGCC180A4ELA0D07\u003c\/li\u003e\n\u003cli\u003eGCC180A4EMA0C07\u003c\/li\u003e\n\u003cli\u003eGCC180AWEHA0A07\u003c\/li\u003e\n\u003cli\u003eGCC180AWEHA0B07\u003c\/li\u003e\n\u003cli\u003eGCC180AWEHA0BD7\u003c\/li\u003e\n\u003cli\u003eGCC180AWEHA0C07\u003c\/li\u003e\n\u003cli\u003eGCC180AWEHA0DC7\u003c\/li\u003e\n\u003cli\u003eGCC180AWEHA0DD7\u003c\/li\u003e\n\u003cli\u003eGCC210A3EHA0A07\u003c\/li\u003e\n\u003cli\u003eGCC210A3EHA0B07\u003c\/li\u003e\n\u003cli\u003eGCC210A3EHA0D07\u003c\/li\u003e\n\u003cli\u003eGCC210A3ELA0907\u003c\/li\u003e\n\u003cli\u003eGCC210A3ELA0A07\u003c\/li\u003e\n\u003cli\u003eGCC210A3ELA0B07\u003c\/li\u003e\n\u003cli\u003eGCC210A3ELA0C07\u003c\/li\u003e\n\u003cli\u003eGCC210A3ELA0D07\u003c\/li\u003e\n\u003cli\u003eGCC210A3EMA0A07\u003c\/li\u003e\n\u003cli\u003eGCC210A4EHA0A07\u003c\/li\u003e\n\u003cli\u003eGCC210A4EHA0D07\u003c\/li\u003e\n\u003cli\u003eGCC210A4ELA0A07\u003c\/li\u003e\n\u003cli\u003eGCC210A4ELA0B07\u003c\/li\u003e\n\u003cli\u003eGCC210A4ELA0D07\u003c\/li\u003e\n\u003cli\u003eGCC210AWEHA0D07\u003c\/li\u003e\n\u003cli\u003eGCC210AWELA0C07\u003c\/li\u003e\n\u003cli\u003eGCC210AWELA0D07\u003c\/li\u003e\n\u003cli\u003eGCC240A3EHA0A07\u003c\/li\u003e\n\u003cli\u003eGCC240A3EHA0B07\u003c\/li\u003e\n\u003cli\u003eGCC240A3EHA0BD7\u003c\/li\u003e\n\u003cli\u003eGCC240A3EHA0C07\u003c\/li\u003e\n\u003cli\u003eGCC240A3EHA0C09\u003c\/li\u003e\n\u003cli\u003eGCC240A3EHA0D07\u003c\/li\u003e\n\u003cli\u003eGCC240A3ELA0A07\u003c\/li\u003e\n\u003cli\u003eGCC240A3ELA0B07\u003c\/li\u003e\n\u003cli\u003eGCC240A3ELA0C07\u003c\/li\u003e\n\u003cli\u003eGCC240A3ELA0D07\u003c\/li\u003e\n\u003cli\u003eGCC240A3EMA0D07\u003c\/li\u003e\n\u003cli\u003eGCC240A4EHA0907\u003c\/li\u003e\n\u003cli\u003eGCC240A4EHA0A07\u003c\/li\u003e\n\u003cli\u003eGCC240A4EHA0AJ7\u003c\/li\u003e\n\u003cli\u003eGCC240A4EHA0B07\u003c\/li\u003e\n\u003cli\u003eGCC240A4EHA0C07\u003c\/li\u003e\n\u003cli\u003eGCC240A4EHA0CD7\u003c\/li\u003e\n\u003cli\u003eGCC240A4EHA0D07\u003c\/li\u003e\n\u003cli\u003eGCC240A4EHA0D09\u003c\/li\u003e\n\u003cli\u003eGCC240A4ELA0907\u003c\/li\u003e\n\u003cli\u003eGCC240A4ELA0A07\u003c\/li\u003e\n\u003cli\u003eGCC240A4ELA0AD7\u003c\/li\u003e\n\u003cli\u003eGCC240A4ELA0B07\u003c\/li\u003e\n\u003cli\u003eGCC240A4ELA0C07\u003c\/li\u003e\n\u003cli\u003eGCC240A4ELA0D07\u003c\/li\u003e\n\u003cli\u003eGCC240A4ELA0D09\u003c\/li\u003e\n\u003cli\u003eGCC240AWEHA0A07\u003c\/li\u003e\n\u003cli\u003eGCC240AWEHA0BD7\u003c\/li\u003e\n\u003cli\u003eGCC240AWEHA0D07\u003c\/li\u003e\n\u003cli\u003eGCC240AWEHA0DC7\u003c\/li\u003e\n\u003cli\u003eGCC240AWELA0D07\u003c\/li\u003e\n\u003cli\u003eGCC300A3EHA0B07\u003c\/li\u003e\n\u003cli\u003eGCC300A3EHA0C07\u003c\/li\u003e\n\u003cli\u003eGCC300A3EHA0D07\u003c\/li\u003e\n\u003cli\u003eGCC300A3EHA0D09\u003c\/li\u003e\n\u003cli\u003eGCC300A3ELA0B07\u003c\/li\u003e\n\u003cli\u003eGCC300A3ELA0BD7\u003c\/li\u003e\n\u003cli\u003eGCC300A3ELA0C07\u003c\/li\u003e\n\u003cli\u003eGCC300A3ELA0D07\u003c\/li\u003e\n\u003cli\u003eGCC300A3EMA0BC7\u003c\/li\u003e\n\u003cli\u003eGCC300A3EMA0D07\u003c\/li\u003e\n\u003cli\u003eGCC300A4EHA0B07\u003c\/li\u003e\n\u003cli\u003eGCC300A4EHA0D07\u003c\/li\u003e\n\u003cli\u003eGCC300A4EHA0D09\u003c\/li\u003e\n\u003cli\u003eGCC300A4ELA0B07\u003c\/li\u003e\n\u003cli\u003eGCC300A4ELA0D07\u003c\/li\u003e\n\u003cli\u003eGCC300A4ELA0D09\u003c\/li\u003e\n\u003cli\u003eGCC300AWEHA0907\u003c\/li\u003e\n\u003cli\u003eGCC300AWEHA0A07\u003c\/li\u003e\n\u003cli\u003eGCC300AWEHA0C07\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trane \/ American Standard","offers":[{"title":"Default Title","offer_id":52576829145451,"sku":"SWT02649","price":68.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/SWT02649-1.jpg?v=1765310798"},{"product_id":"york-s1-02435271000-genuine-oem-furnace-pressure-switch-0-50-wc","title":"York S1-02435271000 – Genuine OEM Furnace Pressure Switch (0.50\" WC)","description":"\u003ch1 data-pm-slice=\"1 3 []\"\u003eYork S1-02435271000 – Genuine OEM Furnace Pressure Switch (0.50\" WC)\u003c\/h1\u003e\n\u003cp data-pm-slice=\"1 3 []\"\u003eThe \u003cstrong\u003eYork S1-02435271000\u003c\/strong\u003e is a precision-calibrated genuine OEM safety pressure switch designed for York, Coleman, and Luxaire gas furnaces. This component acts as a critical \"go\/no-go\" safety monitor for the furnace's venting system. It ensures that the draft inducer motor is creating enough negative pressure to safely exhaust combustion gases out of the home. If the switch does not detect the required vacuum, it prevents the gas valve from opening, protecting your home from potential carbon monoxide buildup.\u003c\/p\u003e\n\u003cp\u003eTechnically, this is a \u003cstrong\u003eSingle Pole Normally Open (SPNO)\u003c\/strong\u003e switch calibrated to \u003cstrong\u003eClose on Fall\u003c\/strong\u003e at \u003cstrong\u003e0.50\" WC\u003c\/strong\u003e (Water Column). This means the internal diaphragm must sense a specific drop in pressure before completing the electrical circuit to the control board. Choosing a genuine York S1-02435271000 ensures that the internal spring tension and diaphragm material are perfectly matched to your furnace's specific blower curve and venting requirements.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features and Function:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Interlock:\u003c\/strong\u003e Prevents ignition if a blocked flue, cracked heat exchanger, or failing inducer motor is detected.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Calibration:\u003c\/strong\u003e Factory-set at 0.50\" WC to maintain the exact safety margins required by the furnace manufacturer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGold-Flash Contacts:\u003c\/strong\u003e Features high-quality internal contacts to prevent oxidation and ensure a reliable electrical signal over thousands of cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect-Fit Housing:\u003c\/strong\u003e Includes the correct hose barb orientation and mounting footprint for a seamless, \"no-modification\" installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Details and Key Specifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e S1-02435271000 (Replaces 024-35271-000)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e York \/ Johnson Controls (Genuine OEM)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Type:\u003c\/strong\u003e Air Pressure Switch\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSet Point:\u003c\/strong\u003e 0.50\" WC (Water Column)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eContact Arrangement:\u003c\/strong\u003e SPNO (Normally Open)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAction:\u003c\/strong\u003e Close on Fall\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnections:\u003c\/strong\u003e Two-wire 1\/4\" male terminals and single vacuum hose port.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e🛠️ HVAC Depot Pro Tip: The \"Blocked Port\" Check\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eBefore replacing this switch, always use a small paperclip or wire to gently clear the \"orifice\" or port on the furnace's collector box where the vacuum hose attaches. Scale and debris often clog this tiny hole, causing a perfectly good pressure switch to stay open. Also, inspect the tubing for any tiny cracks or \"dry rot\" that could cause a vacuum leak and a false \"Switch Open\" error code.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCross-Reference \u0026amp; Compatibility:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe S1-02435271000 is a direct replacement for the following part numbers:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eYork\/JCI Numbers:\u003c\/strong\u003e 024-35271-000, 02435271000, S1-024-35271-000\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSource 1:\u003c\/strong\u003e S1-02435271000\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eExtensive Model Compatibility List:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eYork \/ Coleman \/ Luxaire Furnaces:\u003c\/strong\u003e Compatible with various 80% AFUE and 90%+ AFUE single-stage and two-stage models including the TG8S, TG9S, and TM9 series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":52647825703275,"sku":"S1-02435271000","price":68.91,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/S1-02435311000_2b09976c-a76b-498e-a520-f5ad0dde8e65.jpg?v=1765311803"},{"product_id":"york-pressure-switch-s1-02435311000-0-65-spno-wc-pressure-switch-s1-02435311000-s1-024-35311-000","title":"York S1-02435311000 Pressure Switch -0.65\" PF SPNO WC","description":"\u003ch1\u003eYork S1-02435311000 Pressure Switch -0.65\" PF SPNO WC\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eYork S1-02435311000\u003c\/strong\u003e is a genuine Source 1 OEM pressure switch designed for York, Luxaire, and Coleman gas furnaces. As a primary safety device, this switch monitors the negative pressure created by the draft inducer motor, ensuring the flue is clear and combustion air is flowing before allowing the ignition sequence to begin.\u003c\/p\u003e\n\u003ch2\u003eTechnical Performance\u003c\/h2\u003e\n\u003cp\u003eThis high-precision switch is factory-calibrated to a \u003cstrong\u003e-0.65\" WC (Water Column)\u003c\/strong\u003e set point. Featuring a \u003cstrong\u003eSingle Pole Normally Open (SPNO)\u003c\/strong\u003e configuration, it is engineered to close the electrical circuit only when the specific venting pressure is reached. Being a \u003cstrong\u003eGenuine Source 1\u003c\/strong\u003e part ensures the internal diaphragm is resistant to the corrosive effects of flue gas condensate, preventing the nuisance trips common with universal \"adjustable\" switches.\u003c\/p\u003e\n\u003ch2\u003eKey Features and Function\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFeature 1: Precision Pressure Sensing\u003c\/strong\u003e – Calibrated to -0.65\" WC to ensure exact safety thresholds are met for combustion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFeature 2: OEM Safety Integration\u003c\/strong\u003e – Designed to communicate directly with York control boards for seamless fault code reporting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFeature 3: SPNO Configuration\u003c\/strong\u003e – Single Pole Normally Open logic ensures the furnace fails-safe if pressure is lost or the inducer fails.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFeature 4: Durable Diaphragm\u003c\/strong\u003e – Built with heavy-duty materials to withstand thousands of cycles in high-humidity venting environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Details and Key Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e S1-02435311000 (Replaces 024-35311-000)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e York \/ Source 1 (Genuine OEM)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Type:\u003c\/strong\u003e Air Pressure Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSet Point:\u003c\/strong\u003e -0.65\" WC (Water Column)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Arrangement:\u003c\/strong\u003e SPNO (Normally Open)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Type:\u003c\/strong\u003e 1\/4\" Spade Terminals \/ Hose Barb\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e 0.4 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e🛠️ \u003cstrong\u003eHVAC Depot Pro Tip: The \"Tubing Trap\"\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cp\u003eWhen replacing an S1-02435311000, always inspect the rubber pressure tubing for cracks or \"kinks.\" Even a perfect switch won't close if the tube has a pinhole leak or if the tiny metal orifice on the inducer housing is clogged with rust. Give it a quick poke with a paperclip!\u003c\/p\u003e\n\u003ch2\u003eCross-Reference \u0026amp; Compatibility\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eS1-02435311000\u003c\/strong\u003e is a direct OEM replacement for the following part numbers:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Numbers:\u003c\/strong\u003e 024-35311-000, 02435311000, S1-024-35311-000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCross-Refs:\u003c\/strong\u003e Cleveland Controls RSS-495-011, MPL-9300\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eExtensive Model Compatibility List\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eYork\/Coleman\/Luxaire Series:\u003c\/strong\u003e TG8S, TG9S, TGLS, TM8E, TM8T, TM8V, TM8X, TM9E, TM9T, TM9V, TMLX, TMLV, YP9C, CP9C, LP9C, G8T, G8V, G9T.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":52647827865963,"sku":"S1-02435311000","price":68.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/s1-02435311000-22.jpg?v=1765313973"},{"product_id":"lennox-26w42-genuine-oem-2-stage-pressure-switch-0-95-0-55-w-c-101126-03-on-line-only","title":"Lennox 26W42 – Genuine OEM 2-Stage Pressure Switch (0.95\" \/ 0.55\" W.C., 101126-03) On-Line Only","description":"\u003ch1\u003eLennox 26W42 – Genuine OEM 2-Stage Pressure Switch (0.95\" \/ 0.55\" W.C., 101126-03)\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eLennox 26W42\u003c\/strong\u003e (Model \u003cstrong\u003e101126-03\u003c\/strong\u003e) is a high-precision \u003cstrong\u003eGenuine OEM 2-Stage Pressure Switch\u003c\/strong\u003e designed for Lennox and Armstrong Air high-efficiency gas furnaces. This dual-action safety device monitors the combustion air pressure generated by the inducer motor, ensuring that exhaust gases are being properly vented at both low-fire and high-fire stages before the gas valve is permitted to open.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Performance:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eEngineered specifically for two-stage heating systems, this switch features two distinct calibrated set points: a \u003cstrong\u003eLow-Stage set point of 0.55\" W.C.\u003c\/strong\u003e and a \u003cstrong\u003eHigh-Stage set point of 0.95\" W.C.\u003c\/strong\u003e. This ensures that the furnace operates safely across varying inducer speeds. If the venting system becomes restricted or the inducer motor underperforms at either stage, the switch will break the 24V control circuit, instantly shutting down the ignition process to prevent a carbon monoxide hazard.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features and Function:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFeature 1: Dual-Stage Pressure Monitoring:\u003c\/strong\u003e Specifically calibrated to manage the safety requirements of both low-heat and high-heat cycles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFeature 2: Precision Calibration:\u003c\/strong\u003e Set at 0.55\" and 0.95\" Water Column (W.C.) to maintain strict factory-specified venting tolerances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFeature 3: Fail-Safe Safety Integration:\u003c\/strong\u003e Normally-open contacts ensure the furnace cannot fire if the inducer fan is not creating a sufficient vacuum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFeature 4: Corrosion-Resistant Diaphragm:\u003c\/strong\u003e Built with high-grade internal components to resist the moisture and acidic condensate found in 90%+ AFUE furnace vents.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Details and Key Specifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog Number:\u003c\/strong\u003e 26W42\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel\/Part Number:\u003c\/strong\u003e 101126-03\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Lennox \/ Allied Air (Genuine OEM)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Type:\u003c\/strong\u003e 2-Stage Air Pressure Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Stage Set Point:\u003c\/strong\u003e 0.95\" W.C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-Stage Set Point:\u003c\/strong\u003e 0.55\" W.C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 VAC Control Circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e 0.4 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e🛠️ \u003cstrong\u003eHVAC Depot Pro Tip: The \"Blocked Drain\" Logic\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cp\u003eIn high-efficiency furnaces, a tripped 26W42 switch doesn't always mean the inducer or switch is bad. Often, a clogged condensate drain line will back up water into the inducer housing, blocking the pressure signal. Before replacing the switch, blow through the pressure tubing and check your furnace's trap and drain lines for clogs that might be causing \"nuisance\" trips.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCross-Reference \u0026amp; Compatibility:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003e26W42\u003c\/strong\u003e is a direct OEM replacement for the following part numbers:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Numbers:\u003c\/strong\u003e 101126-03, 10112603, 26W4201, 101126-01\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustry Refs:\u003c\/strong\u003e MPL-9300-V-0.55\/0.95-DEB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eExtensive Model Compatibility List:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLennox G61MPV Series:\u003c\/strong\u003e G61MPV-36B-070, G61MPV-36C-090, G61MPV-60C-090, G61MPV-60D-135\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLennox G60UHV Series:\u003c\/strong\u003e G60UHV-36B-070, G60UHV-60C-090, G60UHV-60D-135\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmstrong Air \/ AirEase:\u003c\/strong\u003e 95% AFUE 2-Stage models matching 0.55\/0.95 specs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"HVAC Parts and Equipment Depot","offers":[{"title":"Default Title","offer_id":52783831810411,"sku":"101126-03","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/26W42.jpg?v=1769033625"},{"product_id":"goodman-0130f00041-oem-furnace-pressure-switch-0-90-wc","title":"Goodman 0130F00041 OEM Furnace Pressure Switch | -0.90\" WC","description":"\u003ch1\u003eGoodman P\/N 0130F00041 – Genuine OEM Furnace Pressure Switch (Single Stage, -0.90\" WC)\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eGoodman 0130F00041\u003c\/strong\u003e is a Genuine Original Equipment Manufacturer (OEM) furnace pressure switch, designed for use in Goodman, Amana, and Janitrol residential gas furnaces. This single-stage, negative pressure-activated switch is a vital safety component, engineered to monitor the draft created by the induced draft motor and prove that the furnace venting system is clear before allowing the main gas valve to open and ignite the burners.\u003c\/p\u003e\n\u003cp\u003eAs an authentic OEM component from Goodman, the 0130F00041 ensures precise set-point calibration (-0.90 inches of water column, \" WC) required by the control board. It features a durable construction, a single-port connection (normally open connection), and specific mounting hardware for a seamless, secure installation. Choosing the original factory part prevents nuisance \"pressure switch lockout\" errors and maintains the furnace's critical safety certifications.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features and Function:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Interlock:\u003c\/strong\u003e Proves successful venting operation to the control board before ignition can occur.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenuine OEM Reliability:\u003c\/strong\u003e Official Goodman replacement built to factory standards for exact fitment and calibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecise Calibration:\u003c\/strong\u003e Factory-set to -0.90\" WC to meet specific furnace design requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle Stage Design:\u003c\/strong\u003e Simple, robust design for use in standard single-stage heating systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Details and Key Specifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 0130F00041\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog #:\u003c\/strong\u003e N\/A (Part number serves as catalog ID)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Goodman (Daikin\/Amana)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Type:\u003c\/strong\u003e Pressure Switch (Single Stage, Negative Pressure)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitch Type:\u003c\/strong\u003e SPST (Single Pole, Single Throw), Normally Open contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSet Point:\u003c\/strong\u003e -0.90 inches of Water Column (\" WC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnections:\u003c\/strong\u003e Single Port, two wiring terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGross Shipping Weight:\u003c\/strong\u003e 0.12 LB (approx)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e🛠️ HVAC Depot Pro Tip: Troubleshooting the Pressure Switch Circuit\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIf your furnace is running the inducer motor but immediately locks out (flashing the pressure switch fault code), the issue isn't always the 0130F00041 switch itself. First, check the rubber tubing connecting the switch to the inducer motor for cracks, blockages, or water accumulation. Second, ensure the furnace's intake and exhaust vents outside are clear of snow, ice, or debris. Only after verifying these common issues should you test the switch with a manometer to confirm it is pulling exactly -0.90\" WC and closing the circuit.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCross-Reference:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe 0130F00041 is a direct OEM replacement for the following part numbers:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM \u0026amp; Catalog Numbers:\u003c\/strong\u003e 0130F00041, P272805.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand Specific Replacements:\u003c\/strong\u003e Direct fit for Goodman, Amana, and Janitrol units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eExtensive Model Compatibility List:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cem\u003eNote: Use 'CTRL+F' to search for your specific model:\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eGoodman\/Amana Furnaces (Specific Models):\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eGME80603BXBA, GME81005CNAA, GME81155CXCA, GME81155CXCB\u003c\/li\u003e\n\u003cli\u003eGMH80604BNBA, GMH81005CNAA, GMH81155CXCA, GMH81155CXCC\u003c\/li\u003e\n\u003cli\u003eAMH80604BNBA, AMH81005CNAA, AMH81155CXCA, AMH81155CXCB\u003c\/li\u003e\n\u003cli\u003eGMS80604BNBA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":52929124303211,"sku":"0130F00041","price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/9683\/9531\/files\/0130f00041.jpg?v=1771604992"}],"url":"https:\/\/tophvacparts.com\/collections\/furnace-pressure-switch.oembed?page=2","provider":"HVAC Parts and Equipment Depot Open To Homeowners and Contractors","version":"1.0","type":"link"}